0% found this document useful (0 votes)
33 views

#8@6"C/C 3-SET: Keyplan:-Consultant

The document appears to be a foundation plan and key details for a building project. It includes a legend defining symbols used, general notes on dimensions and construction details, and labels for columns, plinth beams, piles, and pile caps. Reinforcement sizes and concrete mix ratios are specified. The foundation is designed to support a building with at least 4 stories above ground level.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

#8@6"C/C 3-SET: Keyplan:-Consultant

The document appears to be a foundation plan and key details for a building project. It includes a legend defining symbols used, general notes on dimensions and construction details, and labels for columns, plinth beams, piles, and pile caps. Reinforcement sizes and concrete mix ratios are specified. The foundation is designed to support a building with at least 4 stories above ground level.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

20"

#8@6"C/C
20"

3-SET

20" 5#20

14#20 #8@8"C/C + +
20"

4#20
3-SET
#8
5#20

16" 5#20

14#20 #8@8"C/C + +
24"

4#20
3-SET
#8
5#20

16" 5#25

14#25 #8@8"C/C + +
24"

4#25
3-SET
#8
5#25

20"

14#25 #8@8"C/C + +
20"

3-SET
#8

KEYPLAN:- GENERAL NOTES:- LEGEND :- CONSULTANT:- DRAWN:-


ONLY WRITTEN DIMENSION SHOULD BE FOLLOWED. _ 10"/5" THK.BRICK WORK _ DESIGN:-
PL PLINTH LEVEL
THIS DRAWING SHOULD BE READ IN _
CONJUCTION WITH RELEVANT ARCHITECTURAL _ CONCRETE THK THICKNESS APRO :-
DRAWINGS AND SITE CONDITIONS. _
TYP TYPICAL
ANY DISCREPANCY IN THE DRAWING SHOULD BE BROUGHT _ SAND FILLING #
_
DIAMETER SIGNATURE:-
TO THE KNOWLEDGE OF CONSULTANT _
BEFORE EXECUTION. FFL _ FINISHED FLOOR LEVEL C/C CENTER TO CENTER
_
LOAD HAS BEEN TAKEN FOR (S+4) FLOORS ONLY. _ LVL LEVEL
FGL FINISHED GROUND LEVEL
PILE CAPACITY IS TAKEN AS 25 T.

CLEAR COVER TO MAIN REINFORCEMENT SHALL BE FOR


COLUMN - 40MM, PLINTH BEAM - 50MM, PILE-40mm,
PILE CAP-50mm, BEAM-25mm, SLAB - 20mm .
THE MIX FOR ALL R.C.C. WORK SHALL BE M-20 (1:1.5:3) . PROJECT TITLE:-
ALL THE REINFORCEMENT SHALL BE Fe-500(HYSD BARS) .

MINIMUM DEVELOPMENT LENGTH FOR TOR STEEL SHALL

BE 50d, WHERE "d" IS DIA OF MAIN REINFORCEMENT.


THE LAP SHALL BE STAGGERED AND AVOIDED AT THE
POINT OF MAXIMUM BENDING MOMENT .

ALL DIMENSION & LEVEL ARE IN FEET-INCH.