3101064-EN R10 Io64 and Io500 Compatibility List
3101064-EN R10 Io64 and Io500 Compatibility List
Compatibility List
Subassemblies
Manufacturer Model Description Installation sheet
Edwards D16L-iO-1, -2 Sixteen-zone LED display expander 3101096
SA-232 RS-232 interface card 3101095
SA-CLA Class A interface card 3101094
SA-DACT Dialer 3101099
SA-ETH Ethernet interface card 3101100
XAL250 Loop expander card (iO500 panels only) 3101221
Addressable detectors
Manufacturer Model Description
Edwards SIGA-IPHS Signature combination ion-photo-heat detector
SIGA-PHS Signature combination photo-heat detector
SIGA2-PHS Signature combination photo-heat detector
SIGA-IS Signature ionization smoke detector
SIGA-PS Signature photoelectric smoke detector
SIGA2-PS Signature photoelectric smoke detector
SIGA-SD Signature SuperDuct photoelectric duct smoke detector
SIGA-HFS Signature fixed temperature heat detector
SIGA2-HFS Signature fixed temperature heat detector
SIGA-HRS Signature combination fixed temperature and rate-of-rise
heat detector
SIGA2-HRS Signature combination fixed temperature and rate-of-rise
heat detector
SIGA2-COS Signature CO (carbon monoxide) detector
SIGA2-COS-CA Signature CO (carbon monoxide) detector (Canada)
Addressable modules
Manufacturer Model Description
Edwards SIGA-270 Signature single-action fire alarm station, English
markings, metal
SIGA-270B Signature single-action fire alarm station, English/French
markings, metal
SIGA-270F Signature single-action fire alarm station, French markings,
metal
SIGA-270P Signature two-stage (presignal) fire alarm station, English
markings, metal
SIGA-270PB Signature two-stage (presignal) fire alarm station,
English/French markings, metal
SIGA-278 Signature double-action, single-stage fire alarm station,
plastic
SIGA-CC1 Signature single input signal module, two-gang standard
mount
SIGA-CC1S Signature single input signal synchronization module, two-
gang standard mount
SIGA-UM (ID 0.0 and 1.0) and SIGA-MAB (ID 0.0 and 1.0) smoke detectors [1][2]
Manufacturer Model Description ID Compatible Qty
base
Edwards 429C Photoelectric smoke detector S10A N/A 10
(12/24 VDC)
429CT Photoelectric smoke detector S10A N/A 10
(12/24 VDC) with dual heat
sensor (FT-RoR)
[1] Do not install different smoke detector models on the same circuit
[2] Do not install dry contact devices on the same circuit as smoke detectors if the circuit is
configured for alarm verification
[3] Requires a compatible base and 6260A-100 housing
[4] Do not install on circuits configured for alarm verification
[5] Do not install on circuits configured for alarm verification unless installed in a resistor base
[6] Requires a compatible base and 6260A-CU housing
Notification appliances
Manufacturer Model Description Audible Visible
sync sync
Edwards 202-3A-T, 202-3A-TW, Integrity synchronized strobe N/A Y
202-5A-T, 202-5A-TW,
202-6A-T, 202-6A-TW,
202-7A-T, 202-7A-TW,
202-8A-T, 202-8A-TW
202-15PS, 202-15PSW, Power saver synchronized N/A Y
202-75PS, 202-75PSW strobe
405-3A-T, 405-3A-TW, Integrity synchronized strobe N/A Y
405-5A-T, 405-5A-TW,
405-6A-T, 405-6A-TW,
405-7A-T, 405-7A-TW,
405-8A-T, 405-8A-TW
405-15PS, 405-15PSW, Power saver synchronized N/A Y
405-75PS, 405-75PSW strobe
757-1A-C, 757-1A-CW Integrity chime N/A N/A
757-3A-CS, 757-3A-CSW, Integrity synchronized N/A Y
757-5A-CS, 757-5A-CSW, chime-strobe
757-7A-CS, 757-7A-CSW,
757-8A-CS, 757-8A-CSW
757-1A-T, 757-1A-TW Integrity synchronized Y N/A
temporal horn
757-3A-T, 757-3A-TW, Integrity synchronized Y Y
757-5A-T, 757-5A-TW, temporal horn-strobe
757-7A-T, 757-7A-TW,
757-8A-T, 757-8A-TW
757-1A-H, 757-1A-HW Horn N N/A
757H-15PS, 757H-15PSW, Power saver synchronized Y Y
757H-75PS, 757H-75PSW temporal horn-strobe
CGC-S2VM, CGCF-S2VM Speaker-strobe, 25 VRMS, N/A Y
15 to 95 multi-cd, white [3]
[1] When metallic conductors are installed that extend beyond one building, the circuit(s) are
required to be protected with UL 497B listed transient protectors with the appropriate voltage
ratings for the circuit being protected. When notification appliances are installed outside of a
building (e.g. mounted on an exterior wall) and are connected to an interior circuit that may not
have transient protection, it is recommended that these circuits also be protected with UL 497B
listed transient protection with the appropriate voltage ratings for the circuit being
protected. Consult applicable codes for further information.
[2] UL only
[3] ULC only
Accessories
Manufacturer Model Description
Edwards G1M Genesis synchronization module
G1M-RM Genesis synchronization module, remote mount
MR-101/C, Single multivoltage control relay module, SPDT
MR-101/T
MR-104/C, Four multivoltage control relay module, SPDT
MR-104/T
MR-201/C, Single multivoltage control relay module, DPDT
MR-201/T
MR-204/C, Four multivoltage control relay module, DPDT
MR-204/T
PAM-1 Multivoltage control relay
6254A-003 Auxiliary relay
RA-ENC1 Annunciator cabinet, surface mount, holds one remote
annunciator
RA-ENC2 Annunciator cabinet, surface mount, holds one remote
annunciator and one remote expander
CMS receivers
Manufacturer Model Format
Ademco 685 Contact ID
FBII CP220 Contact ID
Osborne-Hoffman OH 2000E Contact ID, TCP/IP
Radionics D6600 Contact ID
Sur-Gard SG-MLR1 and MLR2 Contact ID
MCDI TLR and TLR+ Contact ID
Contact information
For contact information, see www.est-fire.com.
Copyright © 2014 UTC Fire & Security Americas Corporation, Inc.
All rights reserved.