0% found this document useful (0 votes)
715 views16 pages

Wilo Fire Fighting - 2021

The document provides information on Wilo fire fighting pumps that are NFPA 20 compliant, UL listed, and FM approved. It includes details on pump models, specifications, materials, performance curves, and images of electric motor and diesel engine driven pump systems.

Uploaded by

Meiz Allfarizy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
715 views16 pages

Wilo Fire Fighting - 2021

The document provides information on Wilo fire fighting pumps that are NFPA 20 compliant, UL listed, and FM approved. It includes details on pump models, specifications, materials, performance curves, and images of electric motor and diesel engine driven pump systems.

Uploaded by

Meiz Allfarizy
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Pioneering for You

Product Catalogue – 2020 Edition

Wilo - Fire Fighting Pumps


Fire pump set complete with accessories
“Top quality in
standard applications”
3

Wilo - Fire Fighting Pumps

NFPA 20 Standards Compliant,


UL Listed, FM Approved
Fire Pressure Boosting Systems

Today, fire safety has become an accepted and overemphasized


issue throughout the world. Fire extinguishing systems are one of
the top priorities in commercial, industrial building and
infrastructure facility project such as schools, hospitals, malls,
airports, factories, warehouses, dams, treatment facilities, etc.

Wilo Brochure – Fire Fighting Pump


4

UL LISTED CERTIFICATE

Wilo Brochure – Fire Fighting Pump


5

FM APPROVED CERTIFICATE

FM Approved Certificate from India

FM Approved Certificate from Italy


Wilo Brochure – Fire Fighting Pump
6

WILO FireSet UL / FM
Product Features

1 Design 4 Power supply

Compact design that Main pump with power


integrates pump and reserve based on 150 %
switchgear with UL/FM of the rated volume flow,
approved components available with electric
motor or diesel engine

2 Installation 5 Versatility
Robust axially split case Product configurations
pumps to cover the main available on request,
needs of commercial or depending oninstallation
industrial buildings conditions

3 Equipment 6 Maintenance
Elastic coupling with Safe and easy installation and
misalignment compensator maintenance thanksto
for electric pump and monobloc unit
universal coupling
complies with UL
requirements and is
accepted by FM for diesel
pump

Scope of Supply
Diesel System Electric System Jockey System

→ Pumpset with diesel → Pumpset with electric → Pumpset with mounted


engine driver motor driver electric motor driver
→ Control panel (GDP) → Control panel (GPY) → Control Panel (JP3 and
→ Pressure gauges → Pressure gauges JPY)
→ Air relief valves → Air relief valves
→ Circulation relief valves
→ Batteries
→ Fuel tank

Wilo Brochure – Fire Fighting Pump


7

UL/FM APPROVED PUMP DESIGN

Type Key
SCPFF 80-300 DV
SCPFF Pump series
80 Nominal outlet diameter (mm)
300 Nominal impeller diameter (mm)
DV Hydraulic Variant
•DV: Double Volute
•HA: Hydraulic type “A”
•HB: Hydraulic type “B”

6-8 CME MKII


6 Nominal outlet diameter (inch)
8 Nominal inlet diameter (inch)
CME MKII Pump Series

Pump Material Specification Pump Specification

Casing Cast Iron (GG 30) Max Operating Pressure 20 bar


Impeller Bronze Casting (G-CuSn10) Operating Temperature 10-105 ˚C
Shaft Stainless Steel (AISI 410) Pump Type Axially split case
Shaft Sleeve Stainless Steel (AISI 410) Lubrication Grease
Wearing Ring Bronze Casting (G-CuSn10) Direction of Rotation Clockwise
Sealing Gland Packing (Optionally counter-
clockwise)

Pump Rated Rated Net Rated Net


Approx Speed
Pump Model Connection Capacity Pressure Pressure
(RPM)
(inch) (USGPM) Range (psi) Range (m)

SCPFF 80 - 300 DV 3x4 500 85 - 176 60 – 120 2980


SCPFF 125 - 360 DV 5x6 750 176 – 280 122 – 190 2980
6 - 8 CME MKII 6x8 750 69 – 102 49 – 72 1480
SCPFF 125 - 300 HA 5x6 750 123 – 199 86 – 140 2980
6 - 8 CME MKII 6x8 1000 65 – 100 46 – 70 1480
SCPFF 125 - 360 DV 5x6 1000 162 - 268 112 – 185 2980
SCPFF 150 - 300 HA 6x8 1000 134 - 173 94 – 122 2980
6 - 8 CME MKII 6x8 1250 60 - 98 42 – 68 1480
SCPFF 150 - 300 HA 6x8 1250 130 - 171 91 – 120 2980
6 - 8 CME MKII 6x8 1500 93 65 1480
SCPFF 150 - 300 HA 6x8 1500 122 - 163 86 – 115 2980
SCPFF 200 - 560 HB 8 x 10 2000 100 - 153 70 – 108 1480
SCPFF 200 - 560 HB 8 x 10 2500 99 - 149 69 - 105 1480

Wilo Brochure – Fire Fighting Pump


8

UL/FM APPROVED PUMP WITH ELECTRIC MOTOR

2 5

Key

Coupling Electric Motor


1 → KTR elastic coupling, accepted by FM 4 → UL-compliant motor, accepted by FM
→ Maximum operational reliability (breakage test) → Power corrected with safety factor and high reliability of
→ Prevention of shaft stress through compensation components
systems

Fire pump Switchgear

2 → UL & FM compliance with NFPA 20 as standard 5 → Switchgear components are UL/FM with CE marking as
→ Static and dynamic characteristics tested directly in standard.
production by Wilo → Designed in full accordance with NFPA 70 (NEC)
→ Designed to ensure high efficiency, and easy installation electrical standards
and maintenance operations → Logic of the control microprocessor based on recording
of the sequence of events following pressure changes
as standard.
→ Protection class IP54
→ Star-delta starting

FM Approval FM Approval
3 → The FM logo ensures that the pump is assembled with 6 → Easytransport thanks to the side eyebolts
FM- approved components in a factory authorised by → Standard base plate consisting of a sturdy steel frame to
FM facilitate on-site operations
→ Paintwork with RAL 3000 colour

Wilo Brochure – Fire Fighting Pump


9

UL/FM APPROVED PUMP WITH DIESEL ENGINE

3
6

2
5
7

Key

Coupling Baseplate
1 → Universal coupling compliant with UL requirements and 5 → Standard base plate consisting of a sturdy steel frame to
accepted by FM facilitate on-site operations
→ Maintenance-free with maximum operational reliability → Paintwork with RAL 3000 colour
→ Shaft may be moved in axial, radial and angular → Easy transport thanks to the side eyebolts
directions

Fire pump Combustible Tank

2 → UL & FM compliance with NFPA 20 as standard 6 → Designed and dimensioned in accordance with NFPA 20
→ Static and dynamic characteristics tested directly in standard
production by Wilo → Single-wall tank as standard
→ Designed to ensure high efficiency, and easy installation
and maintenance operations

Diesel Engine Battery Pack


3 → UL/FM-compliant diesel engine with silencer for 7 → Easy transport thanks to the side eyebolts
industrial installation and flexible drainage → Two lead batteries (12 V or 24 V) provide improved
→ Power revised with safety factor in accordance with reliability
NFPA 20 → Dimensioned in accordance with NFPA 20 standard
→ Engine cooling is ensured through a dedicated heat
exchanger

Switchgear FM Approval
4 → Switchgear components are UL/FM with CE marking as 8 → The FM logo ensures that the pump is assembled with
standard FM- approvedcomponentsin a factory authorisedby FM
→ Protection class IP54
→ Simplified installation and maintenance procedures

Wilo Brochure – Fire Fighting Pump


10

WILO FireSet NFPA 20 Std.


Electric Fire Pump (EFP)

→ Pumpset with electric motor driver


→ Local Controller refer to NFPA20 Std.

Diesel Fire Pump (DFP)

→ Pumpset with diesel engine driver


→ Local Controller refer to NFPA Std.
→ Batteries
→ Fuel tank

Jockey Fire Pump (JFP)

→ Pumpset with mounted electric motor driver


→ Local Controller refer to NFPA20 Std.

Local
LocalControllers
Controllers(Refer
(Referto
toNFPA20
NFPA20Std.)
Std.)

→ Refer to NFPA20 standrad of fire pump


control panel
→ Manufactured locally in Indonesia
→ Many types of starter for electric
motor control
→ Wide standard range for electric
motor control panel
→ Diesel engine control panel for 12 and
24VDC
→ Across the line and Y-Delta starter for
jockey pump control panel
→ Wide standard range for jockey pump
control panel

EFP Controller DFP Controller JP Controller

Wilo Brochure – Fire Fighting Pump


11

NFPA20Pump
NFPA20 PumpDesign
Design

End Suction Pump Multistage Pump Axial Split Case Pump

Wilo - Crononorm- NL (EN 733) Wilo - RN, HS PLURO, IPB Wilo - ASP
MISO - PISO (ISO 2858)

Q max. : 650 - 750 m³/h Q max. : 1500m³/h Q max. : 900m³/h

H max. : 150 - 170 m H max. : 900m H max. : 260m

Speed : 2950rpm Speed : 1450 - 2950rpm Speed : 2950rpm

Casing : Cast iron, Ni-CI, cast steel Casing : Cast iron, Ni-CI, cast steel Casing : Cast iron
stainless steel, duplex stainless steel, duplex Impeller : Bronze
stainless steel stainless steel Shaft : Stainless steel (SS410)
Impeller : Cast iron, bronze, stainless Impeller : Castiron, bronze, stainless
steel, duplex stainless steel steel, duplex stainless
Shaft : Stainless steel, steel
Shaft : Stainless steel,
duplex stainless steel
duplex stainless steel

→ Reduced life-cycle costs through → High pressure pump design → Robust design
optimised effisiency levels → Modular design ensures pump version → Customized solutions to meet exact
→ Bidirectional, force - flushed in a variety of materials and versions requirement
mechanical seal which can be adapted to meet → Shaft sleeve to ensure longer shaft
→ Low NPSH values, best cavitation customer demand sprecisely life
properties → Hydraulic pressure compensation → Optimum NPSHr
→ Shaft coupling with or without relieves load on bearings and ensures
→ Low noise and vibration
spacer coupling a longer service life
→ Reduced energy consumption
→ Multiple optional pressure connections
→ Less environmental impact
allow different pressures to be
supplied from a single pump
→ Can be applied as Jockey pump

Wilo Brochure – Fire Fighting Pump


12

NFPA20 Pump Design

Vertical Turbine Pump Standard Glanded Pump Jockey Pump - Multistage Pump

Wilo - VMF, CNE, VAF Wilo - SCP, HSC, GME Wilo - Helix First V / EVO

Q max. : 40.000m³/h Q max. : 3400m³/h Q max. : 80 m³/h

H max. : 450 m H max. : 245 m H max. : 280m

Speed : 980-2950 rpm Speed : 980-2950 rpm Speed : 2950 rpm (1450 rpm optional)

Casing : Cast iron, stainless steel, Casing : Cast Iron Ni-CI, stainless Casing : Cast iron, Stainless steel
cast steel, dupplex stainless steel Impeller : Stainless steel
steel Impeller : Castiron, bronze, stainless Shaft : Stainless steel
Impeller : Castiron, bronze, stainless steel, Ni-CI, duplex stainless
steel, Ni-CI, cast steel, steel
Shaft : Stainless steel, duplex Shaft : Stainless steel, duplex
Stainless steel stainless steel

→ Minimum surface area needed → Higher capacities up to 17.000 m³/h → Efficiency- optimised, laser welded
→ High hydraulic efficiency on request optimised 2D/3Dhydraulics
→ Submerged pump hydraulic → Robustdesign → Corrosion-resistant impellers, guide
vanes and stage housing
→ Design to order asper customer → Customized solution to meet exact
specification requirement → Flow and degassing-optimised
→ Shaft sleeve to ensure longer shaft hydraulics parts
life → Reinforced pump housing, flow and
NPSH optimised
→ Low NPSHr
→ Space-saving and esay maintenance
→ Low noise and vibration
thanks to compact design
→ Reduced energy consumption
→ Space-saving and esay maintenance
→ Less environmental impact
thanks to compact design
(almost 100% recyclable)
→ Particularly sturdy coupling guard
→ Comply to RoHS directive for
European countries

Wilo Brochure – Fire Fighting Pump


13

PUMP DRIVER

Diesel Engine

→ Listed and Non-Listed engine driver → Listed and Non-Listed engine driver
→ Heat exchanger and radiator engine cooling system → Heat exchanger and radiator engine cooling system
→ Build in cooling loop on heat exchanger cooling system → Build in cooling loop on heat exchanger
→ cooling system
→ Low speed and high speed rotation (1470-3000 rpm)
→ Very wide rangeof power 31 kW - 841 kW → High speed rotation (2940 rpm)
→ (depend on rotational speed) → Wide range of power 73 kW - 295 kW
→ Build in DC panel → Build in DC panel
→ Build in silencer with industrial clamped → Build in silencer
→ Exhaust guarding, jacket water heater, and stub shaft
asoptional accessories (standard accessories on
several types)

Electric Motor

→ Listed motor driver → Non-Listed motor driver


→ Low speed and high speed rotation (1500-2900 rpm) → Low speed and high speed rotation (1500-2900 rpm)
→ Very wide rangeof power (depend on rotational speed) → Very wide rangeof power (depend on rotational speed)
→ IP55 → IP55

Wilo Brochure – Fire Fighting Pump


14

Built Up Controllers
UL Listed & FM Approved

Product Model Details Installation Comply to Standard


Diesel Fire Pump Wall UL Listed &
GPD 12 or 24 VDC
Controller Mounting FM approve
Electric Fire Pump GPA Across the line starter
Controller GPY Wye-Delta open starter Rigid base
UL Listed &
GPR Autotransformer starter and
FM approve
GPS Electronic soft starter Wall
GPW Wye-Delta closed Mounting
starter
Jockey Pump JP3 Across the line starter Wall
UL Listed
Controller JPY Wye-Delta open starter Mounting

Non Listed Controller

Product Model Details Installation Comply to Standard

Diesel Fire Pump GFD 12 or 24 VDC Wall Mounting NFPA20


Controller GPD 12 or 24 VDC UL Listed
GFA Across the line starter
GFY Wye-Delta open starter
Electric Fire Pump GFR Autotransformer starter Wall Mounting NFPA20
Controller GFS Electronic soft starter
GFW Wye-Delta closed starter
GPY Wye-Delta open starter UL listed
JP3 Across the line starter
Jockey Pump Controller Wall Mounting UL Listed
JPY Wye-Delta open starter

Wilo Brochure – Fire Fighting Pump


15

Project References

VOZA OFFICE TOWER


Surabaya, Indonesia
Product : Wilo FireSet NFPA20 Std.
Design : Vertical Turbine
Model : 2x CNE 4AC x 6 STG
Capacity : 1000 USGPM @190m

SPRINGLAKE RESIDENCE
Bekasi, Indonesia
Product : Wilo FireSet NFPA20 Std.
Design : Split Casing - Horizontal
Model : 2x ASP 150 GF
Capacity : 1250 USGPM @185m

PODOMORO GOLF VIEW


Jakarta, Indonesia
Product : Wilo FireSet NFPA20 Std.
Design : Split Casing - Horizontal
Model : 2x ASP 100 BF
Capacity : 1250 USGPM @160m

LRT PALEMBANG
Palembang, Indonesia
Product : Wilo FireSet NFPA20 Std.
Design : Split Casing - Horizontal
Model : 26x ASP 80 AF
Capacity : 500 USGPM @100m

UNIVERSITAS NEGERI GORONTALO


Gorontalo, Indonesia
Product : Wilo FireSet NFPA20 Std.
Design : Split Casing - Horizontal
Model : 4x ASP 100 AF
Capacity : 750 USGPM @100m
Wilo Brochure – Fire Fighting Pump
PT Wilo Pumps Indonesia
Altira Business Park Blok A01-A02
Jl. Yos Sudarso Kav.85 Kel. Sunter Jaya
Kec.Tanjung Priok - Jakarta Utara
Jakarta, 14350, Indonesia
T+62 21 2188 2328/2329
www.wilo.com

Warehouse & Service Center


Sentra Niaga 5 Blok8 No.16
Jl. Boulevard Harapan Indah,Pusaka
Rakyat Taruma Jaya- Bekasi
T+62 21 8838 9216/9197
Pioneering for You www.wilo.com

You might also like