Thru SR520: Schottky Barrier Rectifier
Thru SR520: Schottky Barrier Rectifier
THRU
SR5200
SCHOTTKY BARRIER RECTIFIER
VOLTAGE RANGE 20 to 200 Volts CURRENT 5.0 Ampere
FEATURES
* High reliability
* Low switching loss
* Low forward voltage drop
* High current capability
* High switching capability
DO-201AD
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
* Case: Molded plastic
* Lead: MIL-STD-202E method 208C guaranteed
.052 (1.3)
* Mounting: position: Any .048 (1.2)
DIA.
1.0 (25.4)
* Weight: 1.18 grams MIN.
.375 (9.5)
.335 (8.5)
.220 (5.6)
DIA.
.197 (5.0)
1.0 (25.4)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS MIN.
5
TA = 125 OC
SR
SR
55 1.0
580
4 0~
SR
~S
SR
52
R5
56
0~
200
0
SR
0.1 T = 75 OC
54
A
0
2
Single Phase Half Wave 0.01
60Hz Inductive or TA = 25 OC
1 SR520 ~SR540
Resistive Load
SR550~SR560
0.375" (9.5mm) Lead Length
SR580~SR5200
0 0.001
0 50 100 150 0 20 40 60 80 100 120 140
O
LEAD TEMPERATURE, ( C) PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.1 TYPICAL FORWARD CURRENT FIG.2 TYPICAL REVERSE
DERATING CURVE CHARACTERISTICS
50 0.4
CJ, JUNCTION CAPACITANCE, (nF)
INSTANTANEOUS REVERSE CURRENT, (A)
SR520 ~SR540 TJ = 25 OC
0.2
10 SR550~SR560
0.1
0.08
SR580 ~SR5200
0.06
1.0 0.04
TJ = 25 OC 0.02
Pulse width=300mS
1% Duty Cycle
0.1 0.01
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 0.1 0.4 1.0 4 10 40 80100
INSTANTANEOUS FORWARD VOLTAGE, (V) REVERSE VOLTAGE, (V)
150
PEAK FORWARD SURGE CURRENT, (A)
100
75
50
25
0
1 2 5 10 20 50 100
NUMBER OF CYCLES AT 60Hz
FIG.5 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liabi-
lity for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" paramet-
ers which may be included on RECTRON data sheets and/ or specifications ca-
n and do vary in different applications and actual performance may vary over ti-
me. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other rela-
ted applications where a failure or malfunction of component or circuitry may di-
rectly or indirectly cause injury or threaten a life without expressed written appr-
oval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rect-
ron Inc and its subsidiaries harmless against all claims, damages and expendit-
ures.
This datasheet has been downloaded from:
www.DatasheetCatalog.com