The PD 1096 Guidelines set minimum requirements for stair dimensions, ceiling heights for different types of rooms and buildings, room sizes for human habitation, kitchens and toilets, exit door widths and heights, corridor widths, railing heights, and glass thickness and dimensions. Requirements include a minimum stair width of 750mm, stair riser height of 200mm maximum, and tread depth of 200mm minimum. Ceiling heights must be at least 2.4m for rooms with artificial ventilation and 2.7m for rooms with natural ventilation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views

PD 1096 Guidelines Table

The PD 1096 Guidelines set minimum requirements for stair dimensions, ceiling heights for different types of rooms and buildings, room sizes for human habitation, kitchens and toilets, exit door widths and heights, corridor widths, railing heights, and glass thickness and dimensions. Requirements include a minimum stair width of 750mm, stair riser height of 200mm maximum, and tread depth of 200mm minimum. Ceiling heights must be at least 2.4m for rooms with artificial ventilation and 2.7m for rooms with natural ventilation.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

PD 1096 Guidelines

Dimension Description
At least 750 mm Stair Width
Max. of 200 mm Stair Riser
At least 200 mm Stair Tread

2.40 m – Artificial
Ventilation Min. Ceiling Ht.
2.70 m – Natural for Habitable
Ventilation Rooms

2.70 m – 1st Storey


2.40 m – 2nd Storey
2.10 m – Succeeding
Storeys Min. Ceiling Ht.
1.80 m – Mezzanine for Buildings
Eaves over
At least 750 mm required windows
6.00 sq. m w/ min. Rooms for Human
dimension of 2.00 m Habitation

3.00 sq. m w/ min


dimension of 1.50 m Kitchens

1.20 sq. m w/ min.


dimension of 0.90 m Toilet & Bath
Min. stair width:
Occupant load of
900 mm 10-50
Min. stair width:
Occupant load of
1.10 m 50 - above
Distance bet.
3.60 m Landings
at least 1.00 in height Railings
800-900 mm from
the nosing Height of handrails
clear height of 2.40m canopies
Distance to exits
without Sprinkle
Max. of 45 m System
Distance to exits
with Sprinkle
Max. of 60 m System
ess than two (2) fire exits, 500 to 999 Number
occupant
of loads
Exits at least three (3) exits and 1000 occupants
Min. exit door
700 mm width
Min. exit door
2.00 m height
Min. corridor
1.10 m width
00 millimeters in width and not less than
Every
2.00required
meters in
exit
height
doorway shall be of a size as to permit
at least 90 degrees When installed in exit doorways, exit doors shall be capabl
less than 700 millimeters When installed in exit doorways, exit doors shall be capabl
Min. of width of
1/6 of R.O.W sidewalk
800 mm for
sidewalks exceeding
2.00 m in width Plan Strip
1:3 or 1:4 Slope of entryway
Max. slope of
1:10 ramp
thinner than 5.6 millimeters and not longer
Louvered
than Windows
1.20 meters
Regular plate, sheet, or patterned glass i
shall not be less than 3.00 meters
lowest under surface of any part of the balcony
shall not exceed 8.40 meters above thepenthouse
roof
Bathtub and shower enclosures shall be constructed from app
not less than 5.6 millimeters thick
wire-reinforced glass
not less than 4.8 millimeters thick
fully tempered glass
not less than 6.4 millimeters thick
laminated safety glass
not less than 450 millimeters Glass lights located, above the adjacent finished floor or
1.50 square meters or less in area
Glass lights
not greater than 450 millimetersGlass lights when the least dimension
f a size as to permit the installation of a door
doors shall be capable of opening
doors shall be capable of opening

or patterned glass in jalousies and louvered windows


e balcony

constructed from approved shatter-resistant materials, such as:

nt finished floor or walking surface