NoNoteAPPLICABLE TO: m PROPOSAL m PURCHASE l AS BUILT Rev

1 FOR MICRO NUTRIENTS (Sump Pump) UNIT TAG: P-6239


2 SERVICE Sump Cross Feed Pump NO. OF PUMPS REQ. ONE (1)
3 [1] MODEL XPS8 / SSAAA / TWS / TF / STF v PUMP TYPE PROGRESSING CAVITY
4 MANUFACTURER WILDEN ( SERIAL NO. 08-14517

5 INFORMATION BELOW TO BE COMPLETEDm BY PURCHASER o BY MANUFACTURER v BY MANUFACTURER OR PURCHASER


6 GENERAL
7 NO. MOTORS DRIVEN Not Apply OTHER DRIVER TYPE NEUMATIC (3/4" FNPT AIR INLET)
8 PUMP ITEM NO'S Not Apply PUMP ITEM NO'S Not Applay
9 MOTOR ITEM NO'S Not Apply DRIVER ITEM NO'S Not Applay GEAR ITEM NO'S Not Applay
10 MOTOR PROVIDED BY Not Apply DRIVER PROVIDED BY Not Applay GEAR PROVIDED BY Not Applay
11 MOTOR MOUNTED BY Not Apply DRIVER MOUNTED BY Not Applay GEAR MOUNTED BY Not Applay
12 MOTOR DATA SHEET NO. Not Applay DRIVER D.S No. Not Applay GEAR D.S NO. Not Applay

13 m OPERATING CONDITIONS m PUMPED FLUID

14 MIN NORM RAT MAX* TYPE OR NAME OF FLUID


15 CAPACITY @ PT (GPM) 30 36
16 OTHER OPER. COND. (GPM) MIN NORMAL RATED
17 DISCHARGE PRESS (PSIG) 19.4 TEMPERATURE (ºC) 55
18 SUCTION PRESS (PSIG) 1 VAPOR PRESS (PSIA)
19 DIFFERENTIAL PRESS (PSI) 18.4 RELATIVE DENSITY S. G.
20 NPSH AVAILABLE 4 (FT) (PSIA) VISCOSITY (cP)
21 NPIP AVAILABLE m C.L. SUCTION NOZZLE SPECIFIC HEAT Cp (BTU/Lb ºF)
22 NPSHa/NPIP DATUM m TOP OF FOUNDATION CORROSIVE/EROSIVE AGENTS DESCRIPTION
23 m DUTY CYCLE m INTERMITENT l CONTINUOUS m EROSIVE l CORROSIVE
(*) Maximum - mechanical design CHLORIDE CONCENTRATION (PPM)
24 o PERFORMANCE H2S CONCENTRATION (PPM)
25 o RATED CAPACITY (GPM) FLUID l HAZARDOUS m FLAMMABLE m OTHER
26 o NPSHa/NPIPr (FT) (PSIA) m GAS m ENTRAINED
27 o RATED SPEED (RPM) m SLUG FLOW % BY VOL OR GVF
28 o RATED VOLUMETRIC EFFICIENCY % l SOLIDS PARTICLE SIZE DIST. & MIN/MAX (µ)
29 o RATED PUMP EFFICIENCY % m SHAPE m CONCENTR. l HARDNESS
30 o BHP @ MAXIMUM VISCOSITY (BHP)
31 o BHP @ RELIEF VALVE SETTING (BHP) m SITE AND UTILITY DATA (NOT REQUIRED)
32 o BHP @ RATED CONDITION (BHP) LOCATION m INDOOR m OUTDOOR
33 o MAXIMUM ALLOWABLE SPEED (RPM) m HEATED m UNHEATED m UNDER ROOF
34 ELECTRICAL AREA CLASS GROUP DIV
35 ZONE GROUP TEMP CLASS
36 o CONNECTIONS m WINTERIZATION REQD m TROPICALIZATION REQD
37 SITE DATA ELEVATION (FT) PRESSURE (PSIA)
38 SIZE ANSI FACING AMBIENT TEMP: MIN MAX (°F)
39 SUCTION 2 in 150 RF UNUSUAL CONDITIONS
40 DISCHARGE 2 in 150 RF m DUST m FUMES m SALT ATMOSPHERE
41 GLAND FLUSH Not Applay Not Applay Not Applay m OTHER
42 DRAINS* Not Applay Not Applay Not Applay UTILITY CONDITIONS
43 VENTS * Not Applay Not Applay Not Applay ELECTRICITY DRIVERS HEATING CONTROL SHUTDOWN
44 JACKET Not Applay Not Applay Not Applay VOLTAGE
45 HERTZ
46 * PIPE VENTS & DRAINS TO EDGE OF BASEPLATE PHASE

47 [2] APPLICABLE SPECIFICATIONS COOLING WATER INLET RETURN DESIGN MAX


48 API 676 POSITIVE DISPLACEMENT PUMPS - ROTARY TEMP (°F) MAX
49 m GOVERNING SPECIFICATION (IF DIFFERENT) PRESS. (PSIG) MIN
50 m NACE MR0103 NACE MR0175 SOURCE
51 m OTHER INSTRUMENT AIR
52 PRESSURE (PSIG) MAX MIN

53 NOTES
54 [1] IT´S REQUIRED PERISTALTIC PUMP FROM NEUMATIC OPERATION
55 [2] NOT REQUIRED

576815407.xlsx Page 1 of 3
NoNoteINFORMATION BELOW TO BE COMPLETEDm BY PURCHASER o BY MANUFACTURER v BY MANUFACTURER OR PURCHASER Rev
56 o CONSTRUCTION (CONTINUED) MATERIALS [Note 3]
57 CASING m MIN DESIGN METAL TEMP (ºF)
58 o MAXIMUM ALLOWABLE PRESS. (PSIG) (°F) o CASING [Note 3]
59 o MAX. ALLOW. SUCT. PRESS. (PSIG) (°F) o STATOR / LINER [Note 3]
60 o HYDROSTATIC TEST PRESS. (Suct/Disch) (PSIG) o END PLATES
61 ROTATING ELEMENTS o ROTOR (S)
62 ROTOR MOUNT o SELECT o VANES
63 TIMING GEARS o YES o NO o TYPE o SHAFT
64 BEARING TYPE: o RADIAL o THRUST o SLEEVE (S)
65 BEARING NUM.: o RADIAL o THRUST o GLAND (S)
66 LUBRICATION TYPE: m CONSTANT LEVEL OILERS o BEARING HOUSING
67 o PUMPED FLUID v RING OIL v OIL MIST o TIMING GEARS
68 o EXTERNAL o OIL FLOOD o GREASE o ELASTOMERS / GASKETS
69 o LUBRICANT INFO (Visc, etc)
70 m MECHANICAL SEALS QA INSPECTION AND TEST
71 o MANUFACTURER AND MODEL m SPECIAL MATERIAL TEST (Design codes + weld+ inspection sheet)
72 o MANUFACTURER CODE l LOW AMBIENT TEMP. MATERIAL TEST
73 m API 682 AND DATA SHEETS m COMPLIANCE WITH INSPECTORS CHECK LIST
74 m API 682 SEAL FLUSH PLAN l CERTIFICATION OF MATERIALS
75 o API 682 SEAL CODE m SURFACE AND SUBSURFACE EXAMINATIONS
76 m RADIOGRAPHY
77 DRIVER TYPE m ULTRASONIC
78 l OTHER NEUMATIC m MAGNETIC PARTICLE
79 m LIQUID PENETRANT
80 [2] DRIVE MECHANISM m COMPONENT PMI
81 m SELECT m HARDNESS OF PARTS, WELDS & HEAT AFFECTED ZONES
82 v COUPLING MANUFACTURER l VENDOR SUBMIT TEST PROCEDURES
83 v COUPLING TYPE m SUPPLIER TO KEEP REPAIR AND HT RECORDS
84 o RATING (MAX TORQUE) v MODEL
85 o SPACER LENGTH (IN) v SF NON-WIT WIT OBS
86 m COUPLING BALANCED SELECT m SHOP INSPECTION m m m
87 m COUPLING PER API 671 m HYDROSTATIC m m m
88 m COUPLING HUB ATTACHMENT SELECT WITH WETTING AGENT m m m
89 m COUPLING GUARD TYPE SELECT m PERFORMANCE m m m
90 v NON SPARK COUPLING GUARD m RETEST ON SEAL LEAKAGE m m m
91 m NPSH / NPIP m m m
92 [2] MOTOR DRIVER m TRUE PEAK VELOCITY DATA m m m
93 m CODE SELECT m COMPLETE UNIT TEST m m m
94 m ASD SUPPLIED BY SELECT m SOUND LEVEL TEST m m m
95 o MANUFACTURER o TYPE m CLEANLINESS PRIOR TO m m m
96 o FRAME NO. v ENCLOSURE FINAL ASSEMBLY
97 v ORIENTATION SELECT m HIGH DISCH PRESS. @ PLV m m m
98 o POWER (HP) o RPM m CHECK FOR CO-PLANAR AT m m m
99 m VOLTS PHASE HERTZ S.F MOUNTING PAD SURFACES
100 m VARIABLE SPEED RANGE (RPM) m 1 HR MECHANICAL RUN TEST m m m
101 m MINIMUM STARTING VOLTAGE (V) AFTER OIL TEMP STABLE
102 v INSULATION m TEMP RISE m 4 HR MECHANICAL RUN TEST m m m
103 v FULL LOAD AMPS (A) AFTER OIL TEMP STABLE
104 v LOCKED ROTOR AMPS (A) m AUXILIARY EQUIPMENT TEST m m m
105 v STARTING METHOD m OTHER m m m
106 v LUBE m TEST WITH SUBSTITUTE SEAL
107 BEARINGS (TYPE/NUMBER) m SUPPLIER SUBMIT TEST DATA WITHIN 24 HOURS
108 o RADIAL / m INCLUDE PLOTTED VIBRATION SPECTRA
109 o THRUST / m RECORD FINAL ASSEMBLY RUNNING CLEARANCES
110 m PERFORMANCE CURVE & DATA APPROVAL PRIOR TO SHIPMENT
111 NOTES
112 [3] The seller is responsible for selecting the equipment materials, so as to ensure compatibility with the fluid to be pumped.
113 [4] Portable equipment, no foundation required
114 [5]

576815407.xlsx Page 2 of 3
NoNoteINFORMATION BELOW TO BE COMPLETEDm BY PURCHASER o BY MANUFACTURER v BY MANUFACTURER OR PURCHASER Rev
115 PIPING & APPURTENANCES PREPARATION FOR SHIPMENT
116 MANIFOLD PIPING PURCHASER CONNECTION m DOMESTIC m EXPORT EXPORT BOXING REQ'D
117 v VENT v DRAIN v STEAM/COOLING WATER l OUTDOOR STORAGE MORE THAN 6 MONTHS
118 m HEATING JACKET REQ. v COOLING REQUIRED
119 v PIPE v TUBING FITTINGS SURFACE PREPARATION AND PAINT
120 v C.S. v GALVANIZED v S. STEEL l MANUFACTURER'S STANDARD m OTHER (SEE BELOW)
121 v VALVES v CARBON STEEL v S. STEEL m SPECIFICATION No.
122 v FLANGES REQUIRED IN PLACE OF SOCKET WELD UNIONS PUMP:
123 v MOUNT SEAL POT OFF BASEPLATE m PRIMER
124 CONNECTION BOLTING SELECT m FINISH COAT
125 m CADMIUM PLATED BOLTS PROHIBITED BASEPLATE:
126 [2] HEATING AND COOLING m PRIMER
127 HEATING MEDIUM SELECT m FINISH COAT
128 v STEAM JACKET/COOLING (PSIG) (°F)
129 WATER PRESSURE WEIGHTS
130 COOLING WATER REQUIREMENTS o PUMP (LB) o GEAR (LB) o DRIVER (LB)
131 o BEARING HOUSING GPM @ (PSIG) o BASE (LB) o TOTAL WEIGHT
132 o LUBE OIL COOLER GPM @ (PSIG)
133 o SEAL OIL COOLER GPM @ (PSIG) BASEPLATE [note 4]
134 o OTHER GPM @ (PSIG) m BY PUMP MANUFACTURER m SUITABLE FOR EPOXY GROUT
135 o TOTAL COOLING WATER GPM @ (PSIG) m EXTENDED FOR
136 m DRAIN-RIM m DRAIN-PAN
137 [2] INSTRUMENTATION m NON-GROUT CONSTRUCTION
138 m ACCELEROMETER OTHER PURCHASER REQUIREMENTS
139 m PROVISION FOR MTG ONLY NAMEPLATE UNITS l U.S. CUSTOMARY m SI
140 m FLAT SURFACE REQUIRED l RELIEF VALVES BY PUMP MFRG m INTERNAL l EXTERNAL
141 m RADIAL BEARING TEMP. m THRUST BEARING TEMP. PIPING FOR SEAL FLUSH FURNISHED BY: SELECT
142 m TEMP. GAUGES (WITH THERMOWELLS) PIPING FOR COOLING/HEATING FURN. BY: SELECT
143 m PRESSURE GAUGE TYPE m PROVIDE TECHNICAL DATA MANUAL
144 v INSTALATION LIST IN PROPOSAL
145 NOTES
146 [6]
147 [7]
148 [8]
149