Splice ConnectionUC 254X254X73

This document provides the design of a column splice connection between two UC 254x254x73 columns. Key details include: - The splice is a full strength moment connection - Design is based on a reduction factor of 0.8 of the member's section capacity - Bolted connection uses 10 diameter 25mm A325 bolts in double shear - Bolt group capacity is checked to be sufficient in tension and shear - Top and bottom cap plate sizing and thickness are designed to resist the maximum bending moment of 17.55 kN-m

Uploaded by

PavanGupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
816 views1 page

Splice ConnectionUC 254X254X73

This document provides the design of a column splice connection between two UC 254x254x73 columns. Key details include: - The splice is a full strength moment connection - Design is based on a reduction factor of 0.8 of the member's section capacity - Bolted connection uses 10 diameter 25mm A325 bolts in double shear - Bolt group capacity is checked to be sufficient in tension and shear - Top and bottom cap plate sizing and thickness are designed to resist the maximum bending moment of 17.55 kN-m

Uploaded by

PavanGupta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 1

prepared by AB

Project: CDU-A&B Part-B Checked by MN


Approved by LB
Column Splice connection Design
Date 2/7/2021
Type of Splice: Column Splice with Top and Bottom Cap Plates
Connection Type: full strength moment connection
Reduction factor considered for full strength condition 0.8 (80% section capacity considered)
Members details:
Top member section @ splice location - UC 254x254x73

Bottom member section @ splice location - UC 254x254x73

Plastic section modulus zxx - 992000 mm^3


Plastic section modulus zyy - 465000 mm^3

Design Procedure:
Type of Steel - A36 (As per final approved DBR)
yield strength of the steel = 250 N/mm^2
factor of safety for strength design considered for AISC LRFD = 1.5
allowable bending stress = 166.67 N/mm^2
Section Capacity :
for major Axis bending - 132.27 kN-m
for minor Axis bending - 62 kN-m
Shear capacity of member - 904 Kn

50 47 256.3 47 50
Column Cap Plate Sizing :
Section width = 256.3 mm 50
Section Depth = 260.3 mm
Area of Section = 11300 mm2 125
diameter of the bolt considered = 25 mm
Total no. of bolts = 10 nos
edge distance of the bolt considered = 50 mm (min 1.5 times of dia of bolt) 100
distance b/w bolt centre to face of the column = 47 mm
distance b/w bolt centre to face of the column = 45 mm
Base plate width b = 450.3 mm
Base plate depth D = 450.3 mm 125

lever arm between two sides of bolts = 354.3 mm 50


number of bolts on each side = 5 Nos
200 200
due to bending moment bolts are subjected to tension on one side and compression on the other side
Tension force on one side of the bolt group T = 373.32 kN (M/lever arm)
Tensile force on each bolt = 74.7 kN (T/number of bolts)
Shear force on each bolt = 90.4 kN
Type of bolt considered = A325
yield strength of the bolt = 620 N/mm^2
factor for allowable tensile & Shear stress = 0.75
allowable stress for direct tension = 465 N/mm^2
allowable stress for shear = 465 N/mm^2
reduction factor for net to gross area = 0.85
Tension capacity of the bolt = 193.92 kN safe
Shear capacity of the bolt = 193.92 kN safe
Interaction check for bolt tension and shear = 0.851 < 1 safe

Design of the column cap plate:


Thickness of the top plate considered = 25 mm
Thickness of the bottom plate considered = 25 mm
Total thickness considered for the bending = 50 mm `
allowable stress for bending f= 166.7 N/mm^2

Maximum BM M = 17.55 kN-m


Thickness of the plate required t=sqrt(6*M/f*b) = 37.45 mm ok