C ATA LO G

Sectos pole mounted SF6 load break


switch

• Sectos pole mounted SF6 load break


switch


Contents
01. General 04

02. Standards for reference 05

03. Basic switch configurations 06

04. Electrical performance data 07

05. Features 08

06. Accessories 09

07. Electrical and remote control 11

08. Main construction and mounting 14

09. Dimension drawings (unit: mm) 18

10. Ordering type code 21


4 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH


01. General

Product family name "Sectos" is used, when the switch. Sectos can be manually operated or
clause is applicable to all NXA_, NXB_, NXBD_ motor operated for local and remote electric
types. The more specific type markings are control, and can be upgraded easily. NXB is
given, when the clause is applicable to limited designed up to 24kV rated voltages. The unique
types only. feature of this type is integrated earthing
switch option.
Sectos is an SF6 -insulated, outdoor pole mount-
ed load break switch family for overhead lines NXBD is a 3-way load break switch using NXB
and specifically designed for use in modern components. Two independent load break
remote controlled distribution automation switch
systems. The Sectos offers reliable main- in one enclosure with the third tapped way can
tenance free operation even in the most de- be used for easy and reliable line branching in
manding climatic conditions including salt overhead, cable, or mixed networks. NXA is
laden atmospheres, corrosive industrial pollu- available for rated voltages 36kV to IEC
tion, snow and ice. It has excellent load break- standards.
ing and fault making capacity and sati-sfies the
isolation requirements specified for load break
switch. The earthed metal tank prevents all
possible leakage currents across an open

— — —
01 NXB 02 NXBD 03 NXA
01. GENERAL / 02. STANDARDS FOR REFERENCE 5


02. Standards for reference

IEC62271-102 High-voltage switchgear and controlgear -


Part 102: Alternating current discon-nectors and earthing switches

IEC 62271-103 High-voltage switchgear and controlgear -


Part 103: Alternating current switches for rated voltages above 1kV up to and
including 52kV

IEC 62271-1 High-voltage switchgear and controlgear -


Part 1: Common specifications for alternating current switchgear and controlgear

GB/T 3804 High-voltage alternating curr-ent switches for rated voltage above 3.6kV and less
than 40.5kV

GB/T 11022 Common specifications for high-voltage alternating-current switchgear and


controlgear standards
6 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH


03. Basic switch configurations

Two-position load break switch are available for


all NXA_ and NXB_ types.

All NXB_ types are also available with an inte-


grated earthing switch for safe and reliable
earthing of the downstream line. This version is
called a 3-position switch to differentiate from
the standard 2-position switch.

— —
01 Two-position switch 02 Three-position switch

switche d switched switched switch ed


way no.1 1 2 way no.2 way no.1 1 2 way no .2

3 3

tapped wayt apped way

— —
03 Two-position 3-way switch types NXBD_A_ 04 Three-position 3-way switch types NXBD_C_
03. BASIC SWITCH CONFIGURATIONS / 04. ELECTRICAL PERFORMANCE DATA 7


04. Electrical performance data

Insulation level Unit NXB and NXBD NXA


Rated voltage kV 12 24 36
Power frequency withstand voltage, 50Hz
- to earth and between phases kV 42 50 70
- across the isolating distance kV 48 60 80
Lightning impulse withstand voltage
- to earth and between phases kV 75 125 170
- across the isolating distance kV 85 145 195

Current ratings
Rated normal current A 630 630 630
Mainly active load breaking current A 630 630 630 / 400
Number of breaking operations CO n 400 400 100 / 400
Line-charging breaking current A 1.5 1.5 2
Cable-charging breaking current A 50 50 40
Earth fault breaking current A 50 50 130
Cable charging breaking current A
under earth fault conditions A 28 28 80
No-load transformer breaking current 20

Short-circuit ratings
Short-time withstand current, Ik kA/s 20 kA/4s 20 kA/4s 20 kA/3s
Peak withstand current kA 50 50 31.5
Short-circuit making current kA 50 50 31.5
Number of making operations
- main switch 50kA (CL E3) n 5 5
- main switch 31.5kA (CL E3) n 10 10 5
- earthing switch 50kA (CL E2) n 3 3
- earthing switch 31.5kA (CL E3) n 5 5
Creepage distance mm 620 620 1440
Ambient air temperature limits -40°C...+60°C*1 -40°C...+60°C*1 -40°C...+ 60°C
Mechanical endurance (number of close-open operations)
- main switch n 5000 5000 5000
- earthing switch*2 n 2000 2000
Filling pressure (+20°C) bar (abs) 1.4-1.5 1.4-1.5 1.8-1.9
Alarm pressure (+20°C)
- density switch bar (abs) 1.2 1.2 1.65
- density gauge bar (abs) 1.2 1.2 1.6
- low gas lock-out mechanism bar (abs) 1.1 1.1 1.6
Weight
NXB (manual operated type) kg 82
NXA (manual operated type) kg 117
NXBD (manual operated type) kg 138
Degree of protection of the mechanism box IP67 IP67 IP67

“*1”: For CVD -25~°C+60°C.


“*2”: Not suitable for NXA type.
8 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH


05. Features

The high quality 3mm stainless steel are used for The NXB and NXBD type are available as
tank, which is designed for its maximum robus- 2-position (ON-OFF) or 3-position (ON-OFF-
tness and minimum welding line to minimize EARTH) switch. When supplied as a 3-positions
corrosion, and specifically to guarantee the switch the unit has facility to earth the line on one
safety of the operation personnel even with the side of the switch. The earth position of the
internal arc faults at the maximum fault capa-city 3-positions switch is manually operated only.
of the tank the Sectos can withstands an internal
fault without venting hot gases. Capacitor Voltage Divider can be integrated in
the bushings. The typical configuration includes 3
The independent spring operation mechanism or 6 voltage sensors and provide versatile infor-
adopt ABB patent spiral spring, provides a mation of the network condition.
guaranteed load break fault make capability by
ensuring the opening and closing speed of the The switch can be manually controlled or it can be
switch. provided with an integrated motor drive device
for both remote and/or local electrical control.
Standard SF6 gas density units with temperature The motor drive device can easily be retrofitted
compensated are provided by Sectos (density on site to manually operated units.
switch is standard for electrical operated type;
density gauge is standard for manual operated The control cabinet is fitted with an automatism
type), which ensure no misguide to wrong option (equip with advanced FTU type REC615)
operating or lock-out by reliable and stable gas which makes the Sectos an automatic section-
pressure measuring. alizer function. It can be current-counter scheme
with current detection or can be voltage-time
The Sectos is provided with light reflecting scheme with voltage detection.
position indicator which are directly connected to
the switch operating shaft providing clear and The solvent painting system is an option for
unambiguous switch position indication. extreme corrosion environment, which is fully
Indicator made of light reflecting material, which compliance with the requirements of standard
is easily visible from ground level even at night in ISO 12944-9:2018, based on atmospheric corrosi-
driving rain. vity categories CX in standard ISO 12944-2:2017.
Please add special requirement: solvent painting
Advanced and integrated helium leakage in the checklist when ordering this option.
detecting and filling equipment are be adopted,
which ensuring SF6 leakage of each switch is less
than 0.05% strictly per year.
05. FEATURES / 06. ACCESSORIES 9


06. Accessories

Single spring mechanism NXBZ2A Standard locking device NXBZ90


Usually Sectos load break switch is equipped with As an option for sectos, there is available a
single spring mechanism. This kind of spring locking device, which can lock switch at open or
mechanism is suitable for most applications. close position by hook stick manual operated
It's ABB's patent spiral spring, have stable and under the pole. As locking device operates, an
reliable characteristics. When the operating shaft indication sign (locked) becomes visible through
of the switch is turned by manual or motor drive the position indicator window.
device, the spring charges during the first part of
the movement, releases in the last part of the The manual locking device is installed in the
movement, and turns the switch abruptly to new factory, and is equipped with an auxiliary contact,
position.Therefore the switch operates for which provides electrical lock out for electrical
opening and for closing with the speed, which is operated type switch.
completely independent from the operator or
from the operating device. Normally, the motor Low pressure locking device can be used together
operated switch close or open between 1.5-2.5 with special manual locking device NXBZ90.B.
seconds from the command signal initiation.
Density gauge NXAP3
Low pressure lock out device NXBZ4 For manual operated Sectos, density gauge can
As an option for sectos, there is available a block- be standard accessory, which indicats gas
ing device, which blocks the operation of the pressure inside tank.
operating mechanism by means of a mechanical
latch, releases when the inside gas pressure The density gauge is temperature compensated,
reduces to lock-out pressure. As the lock-out variation of the outside air pressure does not
mechanism operates, an indication sign (gas low) affect the indication of the gauge. Therefore is
becomes visible through the position indicator actually indicated the effective pressure of the
window. SF6 gas inside of the tank.

The low pressure lock out device is installed in the Density switch ELEGMDI/0
factory, the lock out device is equipped with an For electrical operated Sectos, density switch is
auxiliary contact, which provide electrical lock standard accessory, which indicates gas pressure
out for electrical operated type switch. state inside tank. The alarm contact of the den-
sity switch is normally closed (NC) and it opens if
The low pressure lock out device is recommended the gas pressure in the tank falls below 1.2 bar
to be used where the outside temperature never (absolute) at 20°C.
falls below -10°C and the altitude doesn't exceed
1,000m above sea level.

— — —
01 Single spring mechanism 02 Low pressure lock out device 03 Manual locking device

— — —
04 Manual locking device 05 Density gauge 06 Density switch
10 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH

Rod suppor t NPAZ L9

Protection insulat or of the


operatin g ro d NPSZ J3 0

Rod suppor t NPAZ L9

Operatin g ro d NP TOT_

Manua l operatin g devic e U EKE3

The density switch is temperature compensated,


variation of the outside air pressure does not Rod support NPAZL9
affect the change over switch contact. Therefore The operating rod is fitted to the pole with rod
is actually showing the density state of the SF6 supports. Normally at least 2 supports are
gas inside of the tank. needed. The extension rod set (if necessary)
includes 1 rod support.
Manual operated type 1
The Sectos are usually operated manually by a Protection insulator of the operating rod
insulated hook stick pulled from ground through NPSZJ30
the hook stick lever in the up mechanism box of The protection insulator is commonly used with
switch. This hook stick lever can be pulled in the wooden or concrete poles. Its purpose is to
left to open and the right to close. And it is the increase the safety of the operator.
only way to be operated for earthing switch when
equipped. Manual operating device UEKE3
The manual operating device UEKE3 is suitable
Hook stick normally can be provided or be for use with sectos load break switch. It can be
purchased locally according to local requirement. locked in open and in closed positions with a
padlock.
Manual operated type 2*
As left picture, Sectos can be selected manual * These accessories are for wood pole mounted,accessories for

operated by device which normally located near concrete pole can be offered if required. And this operated type

to the ground level, and the mechanical can not be selected when inner earthing switch is needed.

movement is transferred to the switch by an


operating rod, which moves up and down.

Operating rods NPTOT_


Operating rod sets are available with rods of
2x4m and 3x3m lengths, each set including rod
supports and necessary joint pieces.
06. ACCESSORIES / 07. ELECTRICAL AND REMOTE CONTROL 11


07. Electrical and remote control

7.1 Electrical control


The Sectos can be electrical operated locally,
which motor device and electrical control cabinet
are needed.

Motor drive device UEMC40K8 UEMC-A2 Stainless steel AISI 304


Motor drive device is mounted inside mechanism Material: IP55
box of side of switch which mounted on the pole. Degree of protection: • Mounting plate
It's can be assembled before leave factory, also Includes: • Self-regulating heater
can be retrofitted on site to manually operated 45W
units when needed by experienced people easily. • 110...250 V AC/DC
• Relay panel
24 VDC is normal for this UEMC 40K8 motor drive • Wooden pole fixing
device, 48 VDC, 60 VDC, 110 VDC, 125 VDC, 220 VDC accessory
can be ordered for needs. Space for: • Batteries
• Charger
Electrical control cabinet UEMC • 1 or 2 operating circuits
Electrical control cabinet is mounted under the • Remote control equipment
pole, normally 2-3 meters above ground level on
the pole. UEMC-A3 Stainless steel AISI 304
Material: IP55
Electrical control cabinet UEMC-_ is including Degree of protection: • Mounting plate
relevant control circuit and components (heater, Includes: • Self-regulating heater
protection MCB, push button, operating circuit, 45W
and so on), which ensure electrical control locally, • 110...250 V AC/DC
and have enough space for relevant FTU (feeder • Relay panel
terminal unit) communication device. • Wooden pole fixing
accessory
For 24 VDC products, relevant charger and batter- Space for: • Batteries
ies are equipped as backup power. Primary power • Charger
should be double-pole voltage transformer or • 1 or 4 operating circuits
from close-by substation. • Remote control equipment

There are 2 standard types of this electrical


control cabinet, UEMC-A2 and UEMC-A3.

The cabinet code REC615-A2/A3 will be used if


equiped with FTU REC615.

— — — —
01 Motor drive device UEMC 40K8 02 Electrical control cabinet UEMC- 03 UEMC-A2 04 UEMC-A3
12 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH

7.2 Remote control and automatic sectionalizer • Adaptable standard configuration for rapid
The control cabinet which is equiped with FTU commissioning
REC615 can realize remote-control, indication, • Web-based parametrization tool with download
measurement function, and automatic possibility
sectionalizer function. • Same configuration tools as for other ABB
relion IEDs such as the 615, 620 and 630 series
7.2.1 Functionality of REC615 • Cyber security features such as audit trail
REC615 is a dedicated grid automation IED • Withdrawable-unit design
(intelligent electronic device) designed for • Large, easy-to-read LCD screen with SLD, local
remote control and monitoring, protection, fault control and parametrization possibilities with
indication, power quality analyzing and automa- dedicated push buttons for safe operation
tion in medium-voltage secondary distribution • Extendable I/O with RIO 600
systems. REC615 is a member of the Relion® • Environmentally friendly design with ROHS
product family and a part of its 615 protection compliance
and control product series. The 615 series IEDs
are characterized by their compactness and Human machine interface
withdrawable-unit design. Re-engineered from As a member of the relion family, REC615 shares
the ground up, the 615 series has been designed the same human machine interface (HMI) look
to unleash the full potential of the IEC 61850 and feel as the other Relion IEDs. The location of a
standard for communication and interoperability push button with a certain function is always the
between substation automation devices. same and the menu structure identical. Conse-
quently, once you become familiar with one Relion
Application IED, you can use them all.
With REC615, the grid reliability can be enhanced,
ranging from basic, non-directional overload Up to five load-break switches can be controlled
protection to extended protection functionality via the IED’s front panel HMI or a remote control
with power quality analyses. Thus, REC615 meets system. To protect the IED from unauthorized
today’s requirements for smart grids and access and to maintain the integrity of infor-
supports the protection of overhead line and mation, the IED is provided with a four-level,
cable feeders in isolated neutral, resistance- rolebased user authentication system, with
earthed, compensated and solidly earthed individual passwords for the viewer, operator,
networks. REC615 is freely programmable with engineer and administrator levels. The access
horizontal GOOSE communication, thus enabling control system applies to the front panel HMI,
sophisticated interlocking functions. The new embedded web browser-based HMI and prote-
adaptable standard configuration allows the IED ction and control IED manager PCM 600.
to be taken into use right after the application-
specific parameters have been set. As a part of an
ABB smart grid solution, REC615 provides
superior fault location, isolation and restoration
(FLIR) to lower the frequency and shorten the
duration of faults (SAIFI/SAIDI).

REC615 offers a variety of features to enhance


grid reliability.
• Multiple controllable objects (up to five load-
break switches)
• Sophisticated protection functionality to
detect, isolate and restore power in all types of
network
• Integrated power quality measurement, includ-
ing voltage dips and swells logging
• Freely programmable
• Load profile and event logging
• Six easily manageable setting groups
07. ELECTRICAL AND REMOTE CONTROL 13

Standardized communication Current based automatic sectionalizer


REC615 supports a variety of communication • Automatic sectionalizers are selfcontained,
protocols for remote communication, such as automatically controlled circuit-opening devices
IEC 60870-5-101/104, DNP3 level 2 and modbus, • Automatic sectionalizers counts the fault
simultaneously also supporting IEC 61850 with current operations of a upstream reclosing
GOOSE messaging. device
• Automatic sectionalizers operates after a
Communication Protocols: preselected number of fault current operations
• IEC 60870-5-101/104 • Automatic sectionalizers isolate the faulted
• DNP3 level 2 section of a distribution feeder after the feeder
• Modbus has been deenergized by e.g. a recloser or
• IEC 61850 with GOOSE messaging communication reclosing CB

7.2.2 Automatic sectionalizer Voltage based automatic sectionalizer


Sectos load break switch can as automatic • Automatic sectionalizers are selfcontained,
sectionalizer with control cabinet easily. Which automatically controlled circuit-opening devices
also includes all remote-function at the same • Lose voltage to open
time, don't need add any hardware components. If switch detect lost voltage two side of
switch, switch open immediately
As the 80-90% of medium voltage overhead line • Add voltage to close (A-Time)
faults are self clearing or transient by nature Either side add voltage and last A-Time switch
and last for a few cycles or seconds. In close
coordination with the main circuit-breaker or • A-Time open lockout
reclosers, The Sectos load break switch is able Either side add voltage and lost it within
to distinguish between transitory and A-Time, switch hold open and lockout
permanent faults occurring in the section it is • B-Time
installed in. Only in case of a permanent fault, it Switch close and start B-Time, If no lost
will isolate the line automatically. voltage till B-Time time out, switch hold close
• B-Time open lockout
From principle and application, the Sectos can Switch close and start B-Time, If lost voltage
as two kinds of sectionalizer, one is current within B-Time, switch open and lockout (load
based sectionalizer (need current detection), side fault)
the other is voltage based sectionalizer (need • Apply to loop and emanative circuits
voltage detection).

— —
01 Current based automatic sectionalizer 02 Voltage based automatic sectionalizer
14 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH


08. Main construction and mounting

8.1 Main construction 8.2.1 Below the crossarm


Below picture take example for NXB load break Sectos can be mounted below the crossarm
switch. easily.

Manual operated type including item1 and 2. Crossarm NPTRNIT6/J401464


The standard crossarm is 80x80 square tube.
Local electrical operated type including item1, 2, There are two standardized lengths, 2,000mm
3 and 6. (NPTRN1T6) and 2,850mm (J401464). See
dimension drawings at the point 9.4.
Remote control or automatic sectionalizer
(current based scheme) type including all items Fixing clamp NXAM 1 or 2
listed. Sectos is easy to install below the crossarm
using these 2 pieces fixing clamps.
Voltage based scheme need voltage detection
only, CT relevant item 4 and 5 are not necessary. See dimension drawings at the point 9.5.

8.2 Mounting modes NXAM1 is use for 80...100x80...100 crossarm. 2 pieces


Sectos load break switch can be mounted below NXAM1 are included in the delivery as a standard
or above crossarm which mounted on single or accessoryfor every type Sectos switch.
double poles easily.
NXAM2 is use for 100...160x100...160 crossarm.

1
CTs

3
5
2 Optional VT
CTs 4 3

5 2 4
7

6
1 Tank

2 Mechanism box

3 Control cable

4 CT measure cable1

5 CT junction box

6 Electric control cabinet

7 Control unit
08. MAIN CONSTRUCTION AND MOUNTING 15


01 Single pole (suitable for NXA and NXB)

1 Crossarm

2 Fixing clamp

3 Spacer plate

4 Surge arrester

2 3 1


02 2 Double poles (suitable for NXA and NXB)

1 Crossarm

2 Fixing clamp

3 Spacer plate

4 Surge arrester
16 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH

2 1 3


NXBD mounted at double poles normally

1 Crossarm

2 Fixing clamp

3 Spacer plate

4 Surge arrester

Spacer plate NXBZ59 8.2.2 Above the crossarm


The spacer plates are required, if a 3-position Sectos (except NXBD) can be mounted above the
switch (with inner earthing switch). crossarm easily.

The spacer plates can be without, if a 2-position Description of crossarm and surge arrester can
switch (without inner earthing switch). be found in point 8.2.1.

The spacer plate is standard for NXBD type. see Fixing clamp
dimension drawings at the point 9.6. NXB is easy to install above the crossarm using
2 pieces fixing clamps---NXAM 1 or NXAM 2.
Surge arresters MWK
To protect the Sectos against atmospheric NXA is easy to install above the crossarm using
overvoltages, it is often necessary to install surge 2 pieces fixing clamps---NXAM 4 or NXAM 5.
arresters on one or both sides of the switch.
normally. It can be purchased locally according to See dimension drawings at the point 9.7.
features of local power network.
NXAM4 is use for 80...100x80...100 crossarm.
NXAM5 is use for 100...160x100...160 crossarm.
08. MAIN CONSTRUCTION AND MOUNTING 17

3 1


NXBD mounted at double poles normally

1 Crossarm

2 Fixing clamp

3 Surge arrester

8.2.3 Mounted on pole directly


Sectos (only NXB) can be mounted on pole
(diameter 180mm to 250mm) directly (as right
picture) when this mounting type is selected, a
set of fixing accessory (named NXBZ204) should
be selected.

Diamet er
180- 25 0 mm
18 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH


09. Dimension drawings (unit: mm)

796(NXB24C_, Creepage distance 620mm)


1128(NXB24D_, Creepage distance 960mm)
862(NXB24R_, Creepage distance 620mm)
932(NXB24R_, Creepage distance 750mm)


9.1 NXB load break switch


9.2 NXBD —
load break switch
09. DIMENSION DRAWINGS (UNIT: MM) 19


9.3 NXA load break switch

Type NPTRN1T6 only for NXB

— Type J401464 for NX A and NX B


9.4 Crossarm NPTRN1T6/J40164
20 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH

NX A M 1 NX A M 2

9.5 Fixing clamp NXAM 1/NXAM 2

NXBZ 59


9.6 Spacer plate NXBZ59

NX A M 4 NX A M 5

9.7 Fixing clamp NXAM 4/NXAM 5
09. DIMENSION DRAWINGS (UNIT: MM) / 10. ORDERING TYPE CODE 21


10. Ordering type code

10.1 Type code Sectos NXB and NXBD

The pole mounted load break switch type NXB 24 C 630 A M 3/24VDC/ 8M/UEMC-A2

Pole mounted load break switch NXB


3-way pole mounted load break switch NXBD
Single phase pole mounted load break switch NXBS

Rated voltage 12kV IEC 12


24kV IEC 24

Type of insulators
Standard silicone rubber insulators with 620mm creepage distance C
Silicone rubber insulators with 960mm creepage distance D
Silicone rubber insulators with 6 CVD sensors and 3-phase CTs CK
Series 400 for underground cable bushings according to IEC E
Outdoor epoxy insulator (available for NXB & NXBS)
620mm creepage distance, 750mm can be ordered if requirement R

Rated current 630A 630

Without earting switch A


Earting switch on one side when NXB C
Earting switches on both sides/disconnectors when NXBD C

Motor operating device M


Only manual operating=BLANK -

Simplified manual operated type 2


Gas measuring accessories in operaing mechanism box
Manual operated type with NXAP3 gas density gauge, with temp.
compensated, for temp.-40℃...+60℃ 3
Motor or remote operated type with ELEGMD 1/0 gas density
switch, with temp. compensated, for temp.-40℃...+60℃ 3
Mechanical low pressure lock-out device possible -10℃...+40℃
without temp. compensated 4

Motor and tripping coil voltage is 24 VDC 24 VDC


Other voltages, 48 VDC, 60 VDC, 110 VDC, 125 VDC, 220 VDC can be ordered for other needs

A control cable is always needed with motor operating device 8M


The alternatives are 8m, 12m, 16m, xxm (max. 25m) xx to be specified

Medium control cabinet with relevant control circuit and


components, spare space ready for radio and ABB FTU UEMC-A2
Big control cabinet with relevant control circuit and components,
spare space ready for bigger size communication device UEMC-A3
Medium control cabinet with relevant circuit and components, equip with FTU REC615 REC615-A2
22 SECTOS POLE MOUNTED SF6 LOAD BREAK SWITCH

10.2 Type code Sectos NXA

The pole mounted load break switch type NXA 36 C 630 A M 3/24VDC/ 8M/UEMC-A2

Pole mounted load break switch NXA

Rated voltage 24kV lEC (*creepage dIstance up to 960mm) 24


36kV IEC (*creepage dIstance up to 1440mm) 36

Type of insulators
Silicone rubber insulators C
Series 400 for underground cable bushings according to IEC E
Silicone rubber insulators with 6 CVD sensors and 3-phase CTs CK

Rated current 630A 630

Without earting switch A

Motor operating device M


Only manual operating=BLANK -

Simplified manual operated type 2


Gas measuring accessories in operaing mechanism box
Manual operated type with NXAP3 gas density gauge, with temp.
compensated, for temp.-40℃...+60℃ 3
Motor or remote operated type with ELEGMD 1/0 gas density
switch, with temp. compensated, for temp.-40℃...+60℃ 3
Mechanical low pressure lock-out device possible -10℃...+40℃
without temp. compensated 4

Motor and tripping coil voltage 24 VDC


Other voltages, 48 VDC, 60 VDC, 110 VDC, 125 VDC, 220 VDC can be ordered for other needs

A control cable is always needed with motor operating device 8M


The alternatives are 8m, 12m, 16m, xxm (max. 25m) xx to be specified

Medium control cabinet with relevant control circuit and


components, spare space ready for radio and ABB FTU UEMC-A2
Big control cabinet with relevant control circuit and components,
spare space ready for bigger size communication device UEMC-A3
Medium control cabinet with relevant circuit and components, equip with FTU REC615 REC615-A2
10. ORDERING TYPE CODE 23

10.3 CT, VT VT (voltage transformer) should be equipped as


CT and VT are option items when order Sectos. power or voltage measuring.

Ring type current transformer KOKU072G4 are TDO 6 type can be provided, also local purchase-
standard type of Sectos, for some special ing according local requirement is available.
application, applies to the fault indicator SPEF
3A2C, current transformer type KOKU072G3 Outdoor voltage transformers TDO 6
(same size with KOKU072G4) can be used. The • Highest voltage for equipment [kV] 12, 17, 5, 24, 25
ratio of it is 400/0.1A, the CT of each phase are • Power frequency test voltage, 1min [kV] 28, 38, 50
connected to the shielded downlead cable • Lightning impulse test voltage [kV] 75, 95, 125
KOHZ11 in the branching box SPEC 6, which also • Max. rated burden, classes [VA/cl]
includes an over voltage protection. 50/0.2-100/0.5-burden

Installed around the bushings of Sectos


• Type: KOKU 072 G4
• Ratio: 400/1A, 600/1A
• Burden/Class: 3 VA/5 P10 0.5 VA/5 P20

ABB Xiamen Switchgear Co., Ltd.
No. 885, FangShanXiEr Road, Xiang’an District,
Xiamen, Fujian, 361101
Tel: 0592 602 6033
Fax: 0592 603 0505

ABB China Customer Service Hot Line


Tel: 800-820-9696 / 400-820-9696
Email: [email protected]

www.abb.com

1YHA000354_EN_REV D 12-2021