M12 Plunger Pump Data: Forged ISO Drawing Specifications

This document provides specifications for the M12 plunger pump model. Key details include: - It is a horizontal triplex plunger pump with 3 plungers and a maximum speed of 500 RPM for intermittent duty or 400 RPM for continuous duty. - Standard materials include carbon steel, ductile iron, stainless steel, and duplex stainless steel. - It has a displacement range of 0.0234 to 0.2754 gallons per revolution and can handle pressures up to 10,000 PSI. - Pump performance curves show flow rates from 2.3 to 138 GPM depending on plunger size and input speed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
145 views4 pages

M12 Plunger Pump Data: Forged ISO Drawing Specifications

This document provides specifications for the M12 plunger pump model. Key details include: - It is a horizontal triplex plunger pump with 3 plungers and a maximum speed of 500 RPM for intermittent duty or 400 RPM for continuous duty. - Standard materials include carbon steel, ductile iron, stainless steel, and duplex stainless steel. - It has a displacement range of 0.0234 to 0.2754 gallons per revolution and can handle pressures up to 10,000 PSI. - Pump performance curves show flow rates from 2.3 to 138 GPM depending on plunger size and input speed.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

38

M12 Plunger Pump Data


62 BHP Continuous Duty (77 BHP Intermittent Duty)

Forged ISO Drawing Specifications


Pump Model M12
Design Standard API-674, Second Edition
Configuration Horizontal Triplex Plunger
Number of Plungers 3
Stroke Length 3.0 Inches
Frame Load Rating 6,000 lbs
Forged Fluid Cylinder Pressure 10,000 psi
Rating
Cast Fluid Cylinder Pressure 3,000 psi
Rating
Pump Weight (Average) 950 lbs
Intermittent Duty Speed Rating 500 RPM
Continuous Duty Speed Rating 400 RPM
Cast ISO Drawing API-674 Max Recommended 400 RPM
Speed
Minimum Speed * 100 RPM
Mechanical Efficiency 90%
Lubrication System (Standard) Splash, Gravity Return
Lubrication System (Optional) Pressurized, Motor Driven
Lube Oil Capacity 3 Gallons
Lube Oil Type SAE 30
Maximum Fluid Temperature 200 °F (400 °F Capability)
Minimum Fluid Temperature -20 °F (-50 °F Capability)
Valve Types Disc Valves, Abrasion Resistant
Valves
* Slower RPM can be achieved with the addition of a pressurized lubrication system

Forged Fluid End Material Cast Fluid End Material Standard Connection Sizes Suction Discharge
A105 Carbon Steel Ductile Iron M1207-M1211 2.0 1.0
A350-LF2 Carbon Steel Nickel Aluminum Bronze M1209-M1216 3.0 1.5
316L Stainless Steel 316L Stainless Steel M1212-M1226 3.0 2.0
2205 Duplex Stainless Steel 2205 Duplex Stainless Steel
* Special Materials available on request * NPT Connections Available

• Consult FMC for specific exceptions to API-674 and NACE standards.


• Consult FMC for any application where inlet pressures will exceed 10% of rated discharge pressure.
• Horsepower based on 90% mechanical efficiency. Actual application horsepower requirements can be calculated using the
equation: BHP = (GPM * PSI) / (1714 * 0.90)
• Direction of rotation is the top of the crankshaft towards the fluid head.

For additional information visit FMCPumps.com


Customer Service
(800) 772-8582
2825 W. Washington St.
Stephenville, TX 76401
M12 Performance Table www.FMCPumps.com

Pump Model Plunger Displacement Maximum Pump Capacity (GPM) @ Input Speed (RPM)
Diameter (in) (GAL/REV) Pressure (PSI) 100 RPM 200 RPM 300RPM 350RPM 400RPM 450RPM 500RPM
M1207 0.875 0.0234 10,000 2.3 4.7 7.0 8.2 9.4 10.5 11.7
M1208 1.000 0.0306 7,600 3.1 6.1 9.2 10.7 12.2 13.8 15.3
M1210 1.250 0.0478 4,900 4.8 9.6 14.3 16.7 19.1 21.5 23.9
M1212 1.500 0.0688 3,400 6.9 13.8 20.6 24.1 27.5 31 34.4
M1214 1.750 0.0937 2,500 9.4 18.7 28.1 32.8 37.5 42.2 46.9
M1216 2.000 0.1224 1,900 12.2 24.5 36.7 42.8 49 55.1 61.2
M1218 2.250 0.1549 1,500 15.5 31 46.5 54.2 62 69.7 77.5
M1220 2.500 0.1912 1,250 19.1 38.2 57.4 66.9 76.5 86 95.6
M1222 2.750 0.2314 1,000 23.1 46.3 69.4 81 92.6 104 116
M1224 3.000 0.2754 850 27.5 55.1 82.6 96.4 110 124 138

M12 NPSHr values for Disc Valves M12 NPSHr values for Disc Valves
with 2-springs (5263970 and 5263971) with 2-springs (5267472 and 5267473)
35 35

30 30

25 25
M1224
20 M1216 20
M1222
M1214
M1220
15 M1212 15
M1218

10 10

5 5

0 0
100 200 300 400 500 100 200 300 400 500

M12 NPSHr values for Disc Valves M12 NPSHr values for AR Valves
with 1-spring (5263970) with 1-spring
35 35

30 30

25 25
M1224
M1224 M1222
20 20
M1222 M1220
M1220 M1218
15 15
M1218 M1216
M1214
10 10

5 5

0 0
100 200 300 400 500 100 200 300 400 500

• Pump capacities shown are based on 100% volumetric efficiency.


• FMC recommends NPSHa (available) exceeds NPSHr (required) by 5 feet of water.
• Take special consideration when calculating NPSHa. Recalculate NPSHa after pump model has been selected for more
accurate values.
• NPSHr values are in feet of water. If you are pumping a different liquid than water, convert the required NPSH from water to
the liquid being pumped by dividing the published NPSHr value by the specific gravity of the liquid being pumped.
• FMC published NPSHr values are based on test data collected on specific pumps at the factory and are estimated values.
Actual NPSHr values for an ordered pump can only be determined by a factor test. For NPSH critical applications, contact the
factory for additional information and request an NPSHr test performed on your pump before shipment.
40

M12 Plunger Pump Data


62 BHP Continuous Duty (77 BHP Intermittent Duty)

Forged Pump Engineering Dimensional Outline

For additional information visit FMCPumps.com


Customer Service
(800) 772-8582
2825 W. Washington St.
Stephenville, TX 76401
www.FMCPumps.com

M12 Plunger Pump Data


62 BHP Continuous Duty (77 BHP Intermittent Duty)

Cast Pump Engineering Dimensional Outline

• Dimensions shown are for general sizing purposes and should not be used of construction. Contact FMC for actual
dimensions of pump ordered.
• FMC reserves the right to modify this information without prior notice.
• Pump drawing dimensions in inches.