S.No Description Unit QTY DC Number Date QTY UOM Remarks: Total 13700

This document contains a bill of quantities for internal electrification work. It lists various electrical items with their descriptions, units, quantities, DC numbers, dates, and remarks. Some key items include: - Supply and wiring for 216 primary light points with switches, conduits and wires - Supply and wiring for 200 secondary light points without switches - Supply and fixing of various socket outlets, switches and accessories - Runs of copper wires of different sizes in PVC conduits for lighting circuits, power sockets, LDBs and PDBs

Uploaded by

muqtar4u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
124 views7 pages

S.No Description Unit QTY DC Number Date QTY UOM Remarks: Total 13700

This document contains a bill of quantities for internal electrification work. It lists various electrical items with their descriptions, units, quantities, DC numbers, dates, and remarks. Some key items include: - Supply and wiring for 216 primary light points with switches, conduits and wires - Supply and wiring for 200 secondary light points without switches - Supply and fixing of various socket outlets, switches and accessories - Runs of copper wires of different sizes in PVC conduits for lighting circuits, power sockets, LDBs and PDBs

Uploaded by

muqtar4u
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 7

S.

NO DESCRIPTION UNIT QTY DC NUMBER DATE QTY UOM REMARKS

INTERNAL ELECTRIFICATION
1 Primary Light points pt 216
Supply and Wiring for Primary Light point with 2 runs of 650 grade
1.5sq.mm ISI Marked FRLS insulated multi strand copper
conductor wires conforming to IS : 694 (with latest amendments)
in 25 mm dia, heavy gauge PVC conduits concealed in wall
/column/ ceiling/ floor including supply and fixing of 1No 6Amp
single pole modular type switch in anodized box and earthing with
1.5sq.mm multi strand FRLS insulated wire run continuously along
the conduit including supply of all fixing materials accessories like
3 plate Ceiling rose / batten holder and inter- connections
complete as required.

713 9/2/2021 2800 mtrs


713 12/13/1901 800 mtrs
713 12/13/1901 1000 mtrs
714 9/2/2021 1000 mtrs
715 9/7/2021 3000 mtrs
665 11/24/2021 3200 mtrs
663 10/27/2021 300 mtrs
Conduit 733 11/22/2021 450 mtrs
Conduit 722 9/17/2021 750 mtrs
1.5sq Wire 722 9/17/2021 400 mtrs
TOTAL 13700
2 Supply and wiring generally same as item 1 above but without pt
control switch looped from Primary Light point 200
Conduit 728 11/1/2021 1000 mtrs

3 Supply and wiring generally same as Item 1 above for Exhaust fan Each
with 6A SP switch in GI box of suitable module with front plate 0
etc.

4 Supply and fixing of flush type 6A, 5 pin combined switch socket Each
outlet in the Lighting control switch boards including 57
interconnections complete as required.

5 Supply and fixing for 1no 6A five pin Independent combined Each
modular type switch Socket outlet point including supply and
fixing of 6A 5 pin combined modular type switch & socket outlet
in a suitable anodized box (Raw power sockets & AC ) 100 Nos

670 11/12/2021 50

6 Supply and fixing for 2nos of 6A five pin Independent combined Each
modular type switch Socket outlet point including supply and
fixing of 16A modular type switch & socket outlet in a suitable
anodized box (Raw power sockets for work station) 35

7 Supply and fixing for 1no 16A/6A 5 pin Universal Modular type Each
Socket outlet including supply and fixing of 1No 16/6Amp 5 pin
modular type combined switch socket fixed in anodized GI box of 60
suitable size. (AC & General)

8 Supply and fixing of factory made 25AMetalclad socket with 25A Nos
SPMCB in MS box including all fixing accessories. 0

9 Run of Mains
Supply and wiring for with the following size 650 V grade FRLS
insulated multi strand copper conductor wires conforming to IS
694 (with latest amendments) in suitable size heavy gauge PVC
conduit concealed in wall/ Ceiling and Insulated multi strand
copper earth wires as specified run continuously along the
conduit including supply of all fixing materials and accessories
interconnections complete as required.

9.1 3C X 1.5 Sq mm Copper flexible multi strand cable in PVC conduit Mtr
(Emergency Lighting) 1300

726 9/28/2021 650 mtrs


728 11/1/2021 500 mtrs

TOTAL 1150
9.2 3C X 2.5 Sq mm Copper flexible multi strand cable in PVC conduit Mtr
(5A Raw power sockets & VAVAC) 1000

722 9/17/2021 400 MTR


728 11/1/2021 2100 mtrs
729 11/3/2021 2100 mtrs
733 11/22/2021 300 MTR
742 11/27/2021 300 MTR

TOTAL 5200
9.3 3C X 2.5 Sq mm Copper flexible multi strand cable in existing Mtr
raceways (5A Raw power sockets for workstations) 1400

9.4 3core 4sq.mm Copper flexible multi strand cable in PVC Conduits Mtr
(General Raw Power 15A Sockets) 1600

722 9/17/2021 2200 MTR


730 11/10/2021 -1800 MTR

TOTAL 400
9.5 2 runs of 2.5 Sq mm Copper flexible multi strand wire with 1 run Mtr
of 2.5Sq.mm wire in PVC conduit (for Lighting circuits)
2500

713 9/2/2021 1000 mtrs


713 9/2/2021 400 mtrs
713 9/2/2021 400 mtrs
728 11/1/2021 3200 mtrs
714 9/2/2021 400 mtrs
714 9/2/2021 1000 mtrs
TOTAL 6800
9.6 2 runs of 6 sq. mm wires with 1 run of 4sq.mm Copper wire in Mtr
suitable size PVC conduit (25A Sockets) 100

9.7 6runs of 6sq.mm wires in suitable size PVC Conduits (for LDBs) Mtr
120

9.8 6runs of 10sq.mm wires in suitable size PVC Conduits (for PDBs) Mtr
70 mtrs
741 11/27/2021 600

TOTAL

UPS WIRING
Schedule 2
1 Supply and fixing of flush type 1X13/5A, intel type 5 pin combined Each
switch socket outlets in the modular type Anodized box including
1no 16A Switch and front plates including interconnections. 10

2 Supply and fixing of flush type 2X13/5A, intel type 5 pin combined Each
switch socket outlets in the modular type Anodized box including
1no 16A Switch and front plates including interconnections. 85

3 Supply and fixing of flush type 3X13/5A, intel type 5 pin combined Each
switch socket outlets in the modular type Anodized box including
1no 16A Switch and front plates including interconnections. 5

4 Supply and fixing of 1no of flush type 16A, 5 pin combined switch Each
socket outlet in the anodized modular type GI box including 16A
5Pin socket, 16A Switch and front plate including
interconnections, concealed in wall complete as required. 8

5 Supply and fixing of factory made single phase 32AMetalclad Each


socket with 32A male -female interlocked socket & plug including 6
all fixing accessories.

6 Run of Mains
Supply and wiring for with the following size 650 V grade FRLS
insulated multi strand copper conductor wires conforming to IS
694 (with latest amendments) in suitable size heavy gauge PVC
conduit concealed in wall/ Ceiling and Insulated multi strand
copper earth wires as specified run continuously along the
conduit including supply of all fixing materials and accessories
interconnections complete as required.

6.1 3core 2.5 sq. mm Copper flexible multi strand cable in existing Mtr
Raceway (UPS Sockets) 1575

6.2 3core 4sq.mm Copper flexible multi strand cable in existing Mtr
Raceway (UPS Sockets) for 16A 250

6.3 3core 6sq.mm Copper flexible multi strand cable in existing Mtr
Raceway (UPS Sockets) for 25A 150

741 11/27/2021 100 MTR

TOTAL 100
6.4 7runs of 6sq.mm wires in suitable sizePVC Conduits (from Server Mtr
DB) 60 MTR
741 11/27/2021 600

6.5 7runs of 16sq.mm wires in suitable size flxible PVC Conduits (UPS Mtr
to Panel) 25 MTR
741 11/27/2021 250

6.6 7runs of 10sq.mm wires in suitable size PVC Conduits (for Work Mtr
station DBs) 80 MTR
741 11/27/2021 800

6.6 4runs of 16sq.mm wires in suitable size PVC Conduits (for UPS Mtr
incomer) 25

8 Distribution Boards
Supply installation Testing and commissioning of TPN MCB Double
Door seven segment Distribution boards dust and vermin
protected and rated for 415V Three phase AC supply operation
including incoming ELMCB as per specifications and required
capacity Neutral bar and Earth terminal complete as required and
installed in flush with wall including all fixing materials required.
MCBs shall conform to IS :8828 and ELCB/RCCB shall conform to
IS: 12640. All the MCBs shall be `D' curve. DBs shall be provided
along with required wire adopter boxes around the DB as
required and dummy's for spare ways in the DB (No claim shall be
allowed for the same).
8.1 6way TPNMCBDB with 63A FP MCB Isolator as incomer and 3nos sets
of 30mA DP RCBO as sub incomers and 18nos 6A/10/16/20A 1
SPMCBs as outgoings (UDBs).

8.2 4way TPNMCBDB with 63A FP MCB Isolator as incomer and3nos sets
of 30mA DP RCBO as sub incomers and 12nos 6A/10/16/20A 1
SPMCBs as outgoings (UDBs).
732 11/13/2021 1

8.3 12way SPNMCBDB with 63A FP MCB Isolator as incomer and 4nos sets
25/32A SPMCBs as outgoings (Server room UDB). 2

9 Supply and laying of following size Heavy gauge PVC conduits


concealed in wall/ ceiling/ floor/ column including supply and
drawing of 12SWG GI wire as fish wire for laying of UPS/ raw
power cables at a later stage and supply of all fixing materials
complete as required.

9.1 20mm Mtr 0


9.2 25mm Mtr 300
9.3 32mm Mtr 200 719 9/15/2021 60 MTR
667 10/29/2021 25 MTR
10 Providing Maintenance free (Chemical powder type) Earth station, Each
including construction of brick pedestal, CI cover and other civil
Engineering works, etc completely as required. 0

11 Brass or bronze flat bar 10x32x300mm mounted on two DMC Each


Insulators (such as acro type 4649) holes of 8mm dia to
accommodate 1/4" connection bolts with washers and butterfly 2
nuts all made of brass or copper.

12 GI /Copper strip / Single core Insulated copper flexible cable


Supply and laying of following size strips/ cable including
excavation and refilling of earth when laid in ground and with all
fixing accessories when laid inside the building including all
necessary interconnections with earth station and equipments.

12.1 25X6mm Electrolytic Copper strip Mtr 10

12.2 8SWG Copper wire Mtr 100

12.3 1C x 25Sq.mm cable along with PVC conduit Mtr 0

12.4 1C x 10Sq.mm cable along with PVC conduit Mtr 200

13 Supply, Fixing of MS slotted Angle iron supports from Roof for Ton
Heavy gauge MS conduits above False ceiling with 2coats of red
oxide paint and 2 coats of synthetic enamel paint including supply
and providing of 10mm dia Anchor fasteners & studs at every 0.1
1mtr interval.

TOTAL
Distribution Boards, MV Panels & MV Cables
Schedule 4
2 Distribution Boards
Supply installation Testing and commissioning of TPN MCB Double
Door seven segment Distribution boards dust and vermin
protected and rated for 415V Three phase AC supply operation
including incoming ELMCB as per specifications and required
capacity Neutral bar and Earth terminal complete as required and
installed in flush with wall including all fixing materials required.
MCBs shall conform to IS :8828 and ELCB/RCCB shall conform to IS
: 12640. All the MCBs shall be `C' curve. DBs shall be provided
along with required wire adopter boxes around the DB as
required and dummys for spare ways in the DB (No claim shall be
allowed for the same).

2.1 8way TPNMCBDB with 40A,100mA, FP ELMCB as incomer and sets


30nos 6A SPMCBs as outgoings. (LDBs) 0

2.2 6way TPNMCBDB with 40A,100mA, FP ELMCB as incomer and sets


18nos 6A SPMCBs as outgoings. (LDBs) 2

729 11/3/2021 2 NOS

TOTAL 2
2.3 4way TPNMCBDB with 40A,100mA, FP ELMCB as incomer and sets
12nos 6A SPMCBs as outgoings. (LPDBs for G.F) 1

2.4 8way TPNMCBDB with 63A, FP MCB as incomer and 3nos of 30mA sets
DP RCBO as sub incomers and 24nos 16A/25A SPMCBs as 1
outgoings. (PDBs)

2.5 6way TPNMCBDB with 63A, FP MCB as incomer and 3nos of 30mA sets
DP RCBO as sub incomers and 18nos 16A/25A SPMCBs as 1
outgoings. (PDBs)

2.6 12way SPNMCBDB with 40A, DP MCB as incomer and 8nos 6/10A sets
SPMCBs as outgoings. (Emergency LDB) 2
.
2.7 8way SPNMCBDB with 40A, DP MCB as incomer and 6nos 6/10A sets
SPMCBs as outgoings. (Emergency LDB for G.F) 1

729 11/3/2021 1 NOS


2.8 63A TPN MCB in enclosures for ACs sets 0
2.9 63/40A,300mA, FP ELMCB in weather proof enclosures for A.C sets
Out door Units 5

3 MV CABLES
Supply and laying of following size 1.1KV grade XLPE insulated and
overall sheathed stranded flat steel strip / wire armoured
aluminium/ copper conductor under ground cable conforming to
IS 1554 part I with latest amendments. The cable shall bear ISI
certification mark. The cables are to be laid on cable tray or on
wall or on ceiling with all fixing accessories

3.1 3.5C X 50 sq. mm (AYFY) RMT 150


741 11/27/2021 30 MTR

3.2 4C X 16 sq. mm (YFY) for AC RMT 35 741 11/27/2021 50 MTR

3.3 4C X 10 sq. mm (YFY) for AC RMT 150 741 11/27/2021 150 MTR

3.4 4C X 6 sq. mm (YFY) for AC RMT 35

3.5 3C X 4 sq. mm (YFY) RMT 0

3.6 1C X 25 sq. mm (YY) in suitable PVC flexible conduit RMT 0

3.7 1C X 16 sq. mm (YY) in suitable PVC flexible conduit RMT 0

3.8 1C X 10 sq. mm (YY) in suitable PVC flexible conduit RMT 0

4 End Terminations

4.1 3.5C X 50sq. mm No 4 742 11/27/2021 2 NOS

4.2 4C X 16 sq. mm (YFY) No 2 742 11/27/2021 12 NOS

4.3 4C X 10 sq. mm (YFY) No 8 742 11/27/2021 30 NOS

4.4 4C X 6 sq. mm (YFY) No 2

4.5 3C X 4 sq. mm (YFY) No 0

4.6 1C X 25 sq. mm (YY) No 0

4.7 1C X 16 sq. mm (YY) No 0

4.8 1C X 10 sq. mm (YY) No 0

5 Earthing
GI /Copper strip
Supply and laying of following size strips including excavation and
refilling of earth when laid in ground and with all fixing
accessories when laid inside the building including all necessary
interconnections with earth station and equipments.

5.1 50X6mm Hot dip GI strip RMT 0

5.2 25X6mm Hot dip GI strip RMT 200 721 9/16/2021 94 MTR
737 12/6/2021 120 MTR

TOTAL 214

5.3 8SWG GI Wire RMT 100

6 SUBSTATION ACCESSORIES
Safety Accessories: Supply and fixing of following fixing
accessories. All accessories shall bear ISI certification mark

6.1 11KV Rubber mats of size 2000X600mm long 12mm thick Each 2
6.2 4.5KG CO2 type fire extinguishers Each 2
6.3 Shock treatment charts (Laminated) Each 1

7 Temporary Lighting and power supply (sockets) arrangement LS


1
during construction period with 1x36W patti type Light fixtures,

Power extension socket boards to2 locations on each floor.


Extension cable from these locations to their usage shall be
vendors scope (other agencies). After completion of
the project, the same material can be taken back by the vendor.

TOTAL

DATA/VOICE/Raceways/Cable Trays/TV Conduits/ Wiring


Schedule 5
1 Supply and laying of following size heavy gauge FRLS PVC conduit
concealed in wall/ ceiling/ floor/ column including supply and
drawing of 12SWG GI wire as fish wire for laying of UPS/ raw
power & DATA/ VOICE cables at a later stage and supply of all
fixing materials complete as required.

1.1 20mm Mtr 150


1.2 25mm Mtr 200
1.3 32mm Mtr 250

2 Supply and laying of 1.6mm Thick Aluminum Floor Raceways of


the following sizes in the floor including cutting the floor with
cutting machine etc wherever required and finishing to normal
level as required (and the debrise shall be shift outside the
premises - as directed by the site engineer). Earth wire of 12SWG
size GI wire shall be run all along the raceways for body earthing.

2.1 25x25mm 1.6mm thick Aluminium Box Section as Race way Mtr 50
716 9/9/2021 18.3 MTR

2.2 50x25mm 1.6mm thick Aluminium Box Section as Race way Mtr 100
716 9/9/2021 18.3 MTR
724 9/22/2021 40.26 MTR

TOTAL 58.56

3 Supply and fixing of Junction boxes made out of 2mm thick MS


sheet including powder coating as required fixed in floor with
required supports. The box shall be provided with removable type
3mm thick powder coated cover. Also required supports to be
provided in side the box.

3.1 450X450X35mm deep junction boxes Each 15


720 9/9/2021 2 Nos

3.2 300X300X35mm deep junction boxes Each 15


720 9/9/2021 4 NOS
726 9/28/2021 2 NOS

3.3 125X125X35mm deep junction boxes Each 60


720 9/9/2021 15 MTR
726 9/28/2021 17 NOS
TOTAL 32
4 Supply and fixing of factory made(MK make or Equivalent) floor Each
mounted Junction boxes with cover shall be suitable to
accommodate 4nos 13A Intel sockets with 2nos16A switches & 0
4nos LAN Outlets.

5 Supply and installation of set of 1no TV outlet in suitable size Each


surface/ concealed box along with modular front plate including
interconnections & terminations at both ends etc. complete as 2
required

6 Supply and wiring of RG11 co-axial TV cable in existing conduits / Mtr


floor raceways 150

7 Supply and wiring of RG6 co-axial TV cable in existing conduits / Mtr


floor raceways 100 Mtr
671 11/15/2021 100

8 Supply, fabrication, erection and commissioning of GI Perforated


type Cable trays with 50mm depth made out of 2mm thick sheet
and supported with 10mm dia rods from ceiling using anchor
fasteners , complete as required. The tray shall be provided with
2-runs x 25mm x 6mm GI strip (For Electrical cables) .

8.1 500mm wide RMT 20

8.2 300mm wide RMT 20

8.3 150mm wide RMT 20

9 Supply, fabrication, erection and commissioning of GI Perforated


type Cable trays with 50mm depth made out of 2mm thick sheet
with 2MM thick cover and supported with 10mm dia rods from
ceiling using anchor fasteners , complete as required

9.1 500mm wide RMT 0

9.2 300mm wide RMT 60


725 9/24/2021 40 MTR
731 11/10/2021 40 MTR
737 12/6/2021 15 MTR
662 10/21/2021 20 MTR
TOTAL 115
9.3 150mm wide RMT 60
725 9/24/2021 60 MTR
733 11/22/2021 30 MTR
737 12/6/2021 15 MTR
662 10/21/2021 25 MTR
TOTAL 130
9.4 500(W)X100 (H) for Server room RMT 15
725 9/24/2021 15 MTR
10 Supply and laying of 80mm dia GI class 'B' pipe for road RMT 0
Crossing for taking the Earth Cables inside the building.

11 Supply and fixing of flush type 2/3 Module Anodized box Each
including required accessories (for Data out lets to be fixed in 20
brick wall / partition )

TOTAL
NT ITEM:

Supply installation Testing and commissioning of TPN MCB Double Door


seven segment Distribution boards dust and vermin protected and
rated for 415V Three phase AC supply
operation including incoming ELMCB as per specifications and required
capacity Neutral bar and Earth terminal complete as required and
1 installed in flush with wall including all fixing
materials required. MCBs shall conform to IS :8828 and ELCB/RCCB shall
conform to IS : 12640. All the MCBs shall be `C' curve. DBs shall be
provided along with required wire adopter boxes around the DB as
required and dummys for spare ways in the DB (No claim shall be
allowed for the same).

New 8WAY VTPN MCCB DB No 1.00

8Way TPN As per Elect BOQ sr no 2.4


a 12WAY(TPN DB) NOS 3.00 732 11/13/2021 3
12way TPNMCBDB with 63A, FP MCB as incomer and 3nos of
30mA DP RCBO as sub incomers and 36nos 16A/25A SPMCBs as
outgoings. (PDBs)
12Way SPN As per Elect BOQ sr no 2.6
b 16WAY(SPN DB) NOS 1.00 729 11/3/2021 1
16way SPNMCBDB with 40A, DP MCB as incomer and 14nos
6/10A SPMCBs as outgoings. (Emergency LDB)

2 Supply, laying and commissioning of following size 1.1KV grade XLPE


insulated armored aluminum
3.5c X 50smt - as per Electrical BOQ Sr no 3.1
a 240X3.5C A2XFY cable Rmt 60.00 741 11/27/2021 70 MTR

b 3.5C x 70 sqmm Al Ar Cable (A2XFY) Rmt 45.00 741 11/27/2021 65 MTR

End Terminations
Providing Indoor ordinary end terminations for the cable specified
3 under above item with compression type steel gland, Bi-metallic lugs
using crimping tool, Insulation tape, Identification tags etc., including
end termination and Earthing of Gland.

3.5c X 50smt - as per Electrical BOQ Sr no 4.1


a) 240X3.5C A2XFY cable NOS 2.00 742 11/27/2021 2 MTR

4 80A TPN
80A TPN MCCB in enclosures for UPS NOS 1.00

5 POP UP BOX NOS 10.00 743 11/26/2021 10 Nos


Supply and fixing 3 Module Table top Pop up
box with 1No 6/10/13A Multistandard Scoket
with 16A Switch with indicator.

6 DISMANTLING WORK
6.1 Toilets (Elec.Dismantling work) EACH 5
6.2 Ground floor (Elec.Dismantling work) EACH 1
6.3 Mezz floor (Elec.Dismantling work) EACH 1
6.4 Lift lobby (Elec.Dismantling work) EACH 5

7 Supply and Installation of LT panels as per attached SLD R6


7.1 MAIN PCC PANEL NOS 1 664 11/22/2021 1 NOS
7.2 AC PANEL(OUTDOOR TYPE) NOS 1 664 11/22/2021 1 NOS
7.3 UPS FLOOR OUTPUT PANEL NOS 1 664 11/22/2021 1 NOS
7.4 AC Panel modification ( Additional fire stop provision added) NOS 1
8 Supply of 1.6mm Thick Aluminum Floor Raceways of the following
sizes in the floor including cutting the floor with cutting machine
etc wherever required and finishing to normal level as required
(and the debrise shall be shift outside the premises - as directed
by the site engineer). Earth wire of 12SWG size GI wire shall be
run all along the raceways for body earthing.

8.1 75x25mm 1.6mm thick Aluminium Box Section as Race way Mtr 135
(Special Sizes)
716 9/9/2021 40.26 MTR

8.2 80x25mm 1.6mm thick Aluminium Box Section as Race way Mtr 135
(Special Sizes)

8.3 100x25mm 1.6mm thick Aluminium Box Section as Race way Mtr 150
(Special Sizes)
716 9/9/2021 109.8 MTR

8.4 150x25mm 1.6mm thick Aluminium Box Section as Race way Mtr 55
(Special Sizes)
716 9/9/2021 69.54 MTR
718 9/10/2021 15.65 MTR
724 9/22/2021 15.8 MTR
TOTAL 100.99
9 TEMPORARY POWER SUPPLY
9.1 DISTRIBUTION BOARDS
8WAY TPN MCB DB NOS 1
incomer-100A,10KA 4P, MCB
outgoings-6nos of 63A c-curve TP MCB

9.2 LT CABLES
3.5C x 95SQMM AL AR CABLE Mtr 10

9.3 CABLE AND TERMINATION


3.5C x 95SQMM AL AR CABLE NOS 2

10 Supply and fixing of Junction boxes made out of 2mm thick MS


sheet including powder coating as required fixed in floor with
required supports. The box shall be provided with removable type
3mm thick powder coated cover. Also required supports to be
provided in side the box.

200X200X35mm deep junction boxes Each 15


726 9/28/2021 12 NOS
720 9/16/2021 30 NOS

12 Energy Meter No 1

13 4cx16sqmm Al Ar.Cable No 1352 5/31/2021 210 Mtr

14 DB's Raceway 100x100mm GI Powder Coated Mtr 35 667 7/27/2021 35 Mtr