[StruxureWare Building Operation] SmartStruxure solution

Enterprise Server
Global view of the system
The entire system, including all of the
SmartStruxure server devices and their associated
devices, can be accessed and configured through
the Enterprise Server.

This overview of the site provides easier mass


change engineering and data analysis. The
Enterprise Server also aggregates the event and
alarm data from all its associated SmartStruxure
server devices. Trend logs can also be aggregated
through the use of extended trend logs.

Text and graphics-based programming tools


Unique to the industry, the Enterprise Server has
both Script and Function Block programming
options. This flexibility assures that the best
programming method can be selected for the
Introduction application.
A SmartStruxure server is the core of the system Centralized alarms and data management
and performs key functionality, such as control
logic, trend logging, and alarm supervision. The Alarms from multiple devices throughout the site,
Enterprise Server is the Windows application including SmartStruxure server devices, are
version of a SmartStruxure server that collects site- collected by the Enterprise Server for centralized
wide data for aggregation and archiving, yet is logging, display, and management. Users can also
flexible enough to run stand-alone applications. The view event logs and trend logs from multiple
Enterprise Server also serves as a single point of servers.
administration through WorkStation or WebStation
for SmartStruxure solution, Schneider Electric’s The Enterprise Server hosts the historical and
intelligent Building Management System. configuration databases. These databases store
current information, including trends, alarms, user
activity, and property information. Alarms can
Features trigger email, SNMP, file, or client notifications,
At the top of the SmartStruxure solution which can include alarm, point value, or trend log
architecture is the Enterprise Server. It is the central data. Notifications can also be triggered periodically
point from which users can configure, control, and by schedules or other binary values.
monitor the entire system.
Authentication and permissions
Networking powerhouse A SmartStruxure solution provides a powerful
The Enterprise Server can run multiple control permission system that is easy to manage, flexible,
© 2017 Schneider Electric. All rights reserved.

programs using a variety of protocols. It can and adapts to all kinds of system sizes. The
manage alarms, users, schedules, and trend logs. permission system provides a security level to the
Data from the Enterprise Server can be delivered highest standards. Authentication is done against
directly to the user or to other SmartStruxure the built-in user account management system or
servers and field devices throughout the site or against Windows Active Directory Domains. The
enterprise. built-in account management system allows an
administrator to set password policies that meet

Schneider Electric | Building Business www.schneider-electric.com/buildings


Trademarks and registered trademarks are the property of their respective owners.
03-19021-02-en April 2017
[StruxureWare Building Operation] SmartStruxure solution
2

stringent CyberSecurity guidelines. When Windows allows for easier engineering and maintenance of
Active Directory is used, the administration costs LonWorks devices from Schneider Electric and
are lower because users do not have to be other vendors. There are some limitations on how
managed in multiple directories. LNS device plug-ins can be used.

Advanced activity log Native Modbus support


It is important to log more than basic activity. In a The Enterprise Server natively integrates Modbus
SmartStruxure solution, every action is logged with RS-485 master and slave configurations, as well as
a timestamp, the user who performed the action, TCP client and server. This allows full access to
and the values that were changed. third-party products and the range of Schneider
Electric products that communicate on the Modbus
WorkStation/WebStation interface protocol, such as power meters, UPS, circuit
Through any client, the user experience is similar breakers, and lighting controllers.
regardless of which SmartStruxure server the user
is logged on to. The user can log directly on to an Web Services support
Enterprise Server to engineer, commission, The Enterprise Server supports the use of Web
supervise, and monitor the SmartStruxure server Services based on open standards, such as SOAP
device as well as its attached I/O modules and field and REST, to consume data into the SmartStruxure
bus devices. For more information, see the solution. Use incoming third-party data
WorkStation and WebStation specification sheets. (temperature forecast, energy cost) over the Web to
determine site modes, scheduling, and
Open building protocol support programming.
One of the cornerstones of SmartStruxure solution
is support for open standards. The Enterprise EcoStruxure Web Services support
Server can natively communicate with three of the EcoStruxure Web Services, Schneider Electric’s
most popular standards for buildings: BACnet, Web Services standard, is natively supported in the
LonWorks, and Modbus. Enterprise Server. EcoStruxure Web Services offers
extra features between compliant systems whether
Native BTL-listed BACnet support within Schneider Electric or authorized third-party
The Enterprise Server communicates directly to systems. These features include system directory
BACnet/IP networks. The Enterprise Server is BTL- browsing, read/write of current values, alarm
listed as a BACnet Building Controller (B-BC), the receipt and acknowledgement, and historical trend
most advance BACnet device profile, and as a log data. EcoStruxure Web Services is secure. User
BACnet Operator Workstation (B-OWS). This name and password are required to log on to the
capability provides access to the full range of system.
BACnet devices from Schneider Electric and other
vendors. See the BTL Product Catalog for up-to- IT friendly
date details on BTL listed software revisions on The Enterprise Server communicates using
BACnet International's home page. The Enterprise networking standards, such as DHCP, HTTP, and
Server can also serve as a BACnet Broadcast HTTPS. This makes installation easy, management
Management Device (BBMD) to facilitate BACnet simple, and transactions secure.
systems that span multiple IP networks.
TLS support
Native LonWorks support Communication between clients and the
The Enterprise Server works with a range of SmartStruxure servers can be encrypted using
© 2017 Schneider Electric. All rights reserved.

LonTalk adapters to communicate to TP/FT-10 Transport Layer Security (TLS 1.2). The servers are
LonWorks networks. Integrated LonWorks delivered with a default self-signed certificate.
functionality enables access to LonWorks devices Commercial Certification Authority (CA) server
from Schneider Electric and other vendors. certificates are supported to lower the risk of
LonWorks networks can be commissioned, bound, malicious information technology attacks. Use of
and configured from the Enterprise Server using the encrypted communication can be enforced for both
built-in LonWorks Network Management Tool. No WorkStation and WebStation access.
third-party tools are needed. To increase ease of
use, LNS device plug-ins are supported. This Supported Protocols
• IP addressing

Schneider Electric | Building Business www.schneider-electric.com/buildings


Trademarks and registered trademarks are the property of their respective owners.
03-19021-02-en April 2017
[StruxureWare Building Operation] SmartStruxure solution
3

• TCP communications • NTP (Network Time Protocol) for time


synchronization throughout the system
• DHCP/DNS for rapid deployment and lookup
of addresses • SMTP or SMTPS with support for SSL/TLS
based authentication, enables sending email
• HTTP/HTTPS for internet access through
messages triggered by schedule or alarm
firewalls, which enables remote monitoring and
control • SNMP enables reception of application alarms
in designated network management tools

Specifications
Hardware requirements
Processor power, memory, and hard disk space should be scaled upwards to accommodate targeted
system size as impacted by the total quantity of SmartStruxure server devices and expected historical
archiving. The Enterprise Server is tested on a machine with an 8-core 3.6 GHz processor, 32 GB of
memory, and a hard drive of 3 TB.
Processor............................................................................Minimum: Intel Core i5 @ 2.0 GHz or equivalent
........................................................................................Recommended: Intel Core i5 @ 3.0 GHz or better
Memory ...............................................................................................................................Minimum: 4 GB
...................................................................................................................Recommended: 8 GB or higher
Hard disk space...............................................................................................................Minimum: 100 GB
Drive...............DVD drive is required if your copy of StruxureWare Building Operation was delivered on disc.
Other devices ....................................................Microsoft mouse or compatible pointing device is required.
Software requirements
Operating systems ..........................................................................................Microsoft Windows 7 (32-bit)
.......................................................................................................................Microsoft Windows 7 (64-bit)
....................................................................................................................Microsoft Windows 8.1 (32-bit)
....................................................................................................................Microsoft Windows 8.1 (64-bit)
.....................................................................................................................Microsoft Windows 10 (64-bit)
.................................................................................................Microsoft Windows Server 2008 R2 (64-bit)
.......................................................................................................Microsoft Windows Server 2012 (64-bit)
.................................................................................................Microsoft Windows Server 2012 R2 (64-bit)
The following Microsoft Windows 7 editions are supported: Professional, Enterprise, and Ultimate.
The following Microsoft Windows 8.1 editions are supported: Pro, Pro N, Enterprise, and Enterprise N.
The following Microsoft Windows 10 editions are supported: Pro and Enterprise.
The following Microsoft Windows Server 2008 R2 editions are supported: Standard, Web, Enterprise,
Datacenter, and Itanium.
The following Microsoft Windows Server 2012 and Microsoft Windows Server 2012 R2 editions are
supported: Datacenter, Standard, Essentials, and Foundation.
Required additional software...............................................................Microsoft .NET Framework 4.5 or 4.6
Communication
© 2017 Schneider Electric. All rights reserved.

TCP .........................................................................................................................Binary, port fixed, 4444


HTTP.............................................................................................Non-binary, port configurable, default 80
HTTPS........................................Encrypted supporting TLS 1.2, 1.1, and 1.0, port configurable default 443
SMTP........................................................................................Email sending, port configurable, default 25
SMTPS ...................................................................................Email sending, port configurable, default 587
SNMP............................................................................................................................................version 3
.......................................................................................................Application alarm distribution using trap
NTP ............................................................................................................................Time synchronization

Schneider Electric | Building Business www.schneider-electric.com/buildings


Trademarks and registered trademarks are the property of their respective owners.
03-19021-02-en April 2017
[StruxureWare Building Operation] SmartStruxure solution
4

BACnet ....................................................................................BACnet/IP, port configurable, default 47808


.......................................................................................................BTL B-BC (BACnet Building Controller)a
...............................................................................................BTL B-OWS (BACnet Operator Workstation)a
a) See the BTL Product Catalog for up-to-date details on BTL listed firmware revisions on BACnet
International's home page.
Supports the following LonTalk adapters:..................................................................................NIC709-PCI
...............................................................................................................................................NIC709-USB
.........................................................................................................................................NIC709-USB100
...................................................................................................................................................NIC709-IP
........................................................................................................................................................NIC852
Other protocols may be used for particular additional functionality. See Technical Documentation.
LNS
LNS version..................................................................................................................................OpenLNS
Installed on WorkStation PC
LonMark
Resource files version .........................................................................................................................14.00
Part number
SW-ES-BASE-0, StruxureWare Building Operation Enterprise Server license for a PC server, includes
Reports Server license
(No maintenance subscription included) .......................................................................SXWSWESXX00001
Add-on options
SW-EWS-1, EcoStruxure Web Services (run-time) option
Consume only for one SmartStruxure server, no maintenance.....................................SXWSWEWSX00001
SW-EWS-2, EcoStruxure Web Services (run-time) option
Serve & Consume for one SmartStruxure server, no maintenance ...............................SXWSWEWSX00002
SW-EWS-3, EcoStruxure Web Services (run-time) option
Serve & Consume, plus Historical trend log data for one SmartStruxure server, no
maintenance ...............................................................................................................SXWSWEWSX00003
SW-GWS-1, Web Services (Generic Consume) option
For one SmartStruxure server, no maintenance ..........................................................SXWSWGWSX00001
SW-SNMP-1, Alarm notifications via SNMP option
For one SmartStruxure server, no maintenance...........................................................SXWSWSNMP00001
SW-SMARTDRIVER-1, Communication to external devices via SmartDriver
For one SmartDriver license.........................................................................................SXWSWSDRV00001

© 2017 Schneider Electric. All rights reserved.

Schneider Electric | Building Business www.schneider-electric.com/buildings


Trademarks and registered trademarks are the property of their respective owners.
03-19021-02-en April 2017

You might also like