Previous Year Question Paper and Solved Answer
Previous Year Question Paper and Solved Answer
PART A
Answer all questions, each carries 5 marks.
PART A
Answer all questions, each carries 5 marks.
Microgrid is a group of interconnected loads and distributed energy resource with clearly
defined boundaries that acts as a single controllable entity with respect to grid. A Microgrid can
connect and disconnect from the grid to enable it to operate in both grid connected or island-
mode.
or
Its a low-voltage power distribution system integrated with distributed energy resources (DERs)
and controllable loads, which can be operated with or without the main grid
1. Explain with diagram, the working of energy router based interconnecting frame work for
the micro grid system (7 MARK)
Energy router based interconnecting framework for the micro grids system
Energy router serves as an energy hub to setup an electrical connection between Microgrid and
the utility grid.
2. With neat sketch, explain typical micro grid configuration? (10 MARK)
The Microgrid consists of three radial feeders (A, B and C) to supply the electrical and
heat loads. It also has two CHP and two non-CHP microsources and storage devices.
Microsources and storage devices are connected to feeders A and C through microsource
controllers (MCs). The microsources have plug-and-play features. They are provided with PEIs
to implement the control, metering and protection functions during stand-alone and grid-
connected modes of operation. Some loads on feeders A and C are assumed to be priority loads
(i.e. requiring uninterrupted power supply), while others are non- priority loads. Feeder B
contains only non-priority electrical loads.
Modes of operation
The Microgrid is coupled with the main medium voltage (MV) utility grid (denoted as ‘main
grid’) through the PCC (point of common coupling) circuit breaker CB4 as per standard
interface regulations.
In grid-connected mode, the Microgrid remains connected to the main grid either totally or
partially, and imports or exports power from or to the main grid. In case of any disturbance in
the main grid, the Microgrid switches over to stand-alone mode while still feeding power to
the priority loads.
This can be achieved by either
disconnecting the entire Microgrid by opening CB4 or
disconnecting feeders A and C opening CB1 and CB3.
3.What is the function of energy management module in micro grid configuration (3 MARK)
EMM provides the set points for active and reactive power output, voltage and
frequency to each MC.
It must ensure
Microsources supply heat and electrical loads to customer satisfaction.
Microgrids operate satisfactorily as per the operational a priori contracts with main
grid.
Microgrids satisfy its obligatory bindings in minimising system losses and emissions
of greenhouse gases and particulates.
PART A
Answer all questions, each carries 5 marks.
1. What is an active distribution network? Explain its relevancy in microgrid system.
In order to harness clean energy from renewable DERs, active distribution networks should also
employ future network technologies leading to smart grid or Microgrid networks.
Active Distribution N/w gaining growth due to several factors such as:
Increasing desire of policy makers for accommodation of DERs with energy storage
devices
Carbon commitment in reducing emissions by 50% by 2050.
Provides reliable power
Motivating the distribution n/w operators towards better asset utilization and
management by deferral of replacement of age old assets etc.
PART B
Answer questions, each carries 10 marks
FIG shows typical dc Microgrid system interconnected with main system at PCC,
which can be an HVDC transmission line or utility grid from the conventional power plants.
2. Explain the role of central controller in stand-alone and grid connected mode of operation
of Microgrid. (5 mark)
Role of central controller in standalone and grid connected mode (2.5 + 2.5)
Initiating a local black start to ensure improved reliability and continuity of service.
Switching over the Microgrid to grid-connected mode after main grid supply is restored
without hampering the stability of either grid
Ensuring synchronised operation with the main grid maintaining the power exchange
at priori contract points
The main function of MC is to independently control the power flow and load-end
voltage profile of the microsource in response to any disturbance and load changes.
MC also participates in economic generation scheduling, load tracking/management and
demand side management by controlling the storage devices.
It must also ensure that each microsource rapidly picks up its generation to supply its
share of load in stand-alone mode and automatically comes back to the grid-connected
mode with the help of CC.
PART A
Answer all questions, each carries 5 marks.
2. Draw the layout of typical micro grid and explain the components in detail. (10)
Refer PYQ MAY(R,S)2019
Layout (5); Explanation-5marks (PCC, sources CHP and Non CHP, CC,MC etc )
3. What is distributed generation? Explain how it enhances the performance of utility grid.
DER produce clean and ecofriendly electrical energy; hence exploitation of RES
reduces environmental pollution and global warming.
DG s/m improves overall efficiency by enhancing tri-generation, co-generation or CHP
plants for utilizing the waste heat for industrial /commercial /domestic applications.
Utilization of thermal heat by CHP plants reduces thermal pollution also.
T & D losses are negligible since they are located close to the load.