The document outlines ASME safe distance requirements for hydro-testing, providing a formula to calculate the safe distance from a pipe undergoing hydro-testing based on the pipe's inner diameter, length divided by diameter, and test pressure. It then works through an example calculation with given values of 0.9 meters for inner diameter, 230 meters for length divided by diameter, and 100 bars of test pressure, resulting in a safe distance of 18.84 meters.

Uploaded by

um er
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
271 views

ASME Safe Distance Formula For Hydrotesting

The document outlines ASME safe distance requirements for hydro-testing, providing a formula to calculate the safe distance from a pipe undergoing hydro-testing based on the pipe's inner diameter, length divided by diameter, and test pressure. It then works through an example calculation with given values of 0.9 meters for inner diameter, 230 meters for length divided by diameter, and 100 bars of test pressure, resulting in a safe distance of 18.84 meters.

Uploaded by

um er
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

ASME SAFE DISTANCE REQUIREMENTS FROM HYDRO-TEST

D= 0.9 M
a= 230 M
p= 100 Bar
Unit
SAFE DISTANCE Result= 18.8375710300511 Meter

LEGEND: D Inner Dia of pipe Meter


A Length of pipe Devide into Dia of pipe Meter
P Test Pressure Bar
8/0.025 8/0.025