Instruction Manual For FWG
Instruction Manual For FWG
Shipname/
Hull No.: ____________________
Customer: ____________________
Any comments regarding possible errors and omissions or suggestions for improvement
of this publication would be gratefully appreciated.
Copies of this publication can be ordered from your local Alfa Laval company.
2 O26WE08.fm
Table of Contents
System Description
1.0.0 Working Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
1.1.0 Freshwater Quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
1.2.0 Main Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
Operating Instructions
1.0.0 Starting and Stopping Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
1.1.0 Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
1.1.1 Evaporation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
1.1.2 Condensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
1.2.0 Adjustment of Hot Water Flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
1.3.0 Adjustment of Sea Cooling Water. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
1.4.0 Stopping the Plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
1.5.0 Long Term Standstill. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
Maintenance
1.0.0 Why you need to perform regular maintenance duties . . . . . . . . . . . . . . . . . page 13
1.1.0 Overhaul Intervals. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
1.2.0 Maintenance of Separator Vessel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
1.3.0 Maintenance of Evaporator Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
1.4.0 Maintenance of Condenser Section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
1.5.0 Renewal of Plate Heat Exchanger Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . page 18
1.5.1 Removal of Old Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
1.5.2 Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
1.5.3 Preparation of New Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19
1.5.4 Fitting New Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19
Trouble-Shooting
1.0.0 Test Sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
O26WE08TOC.fm 3
Table of Contents
Salinometer
1.0.0 Salinometer Type DS-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
1.1.0 Technical Specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
1.2.0 Installation (for DS-20). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
1.3.0 Instructions for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38
1.3.1 Testing the Instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38
1.3.2 Adjustment of Alarm Level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38
1.3.3 Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 39
Spare Parts
1.0.0 Ordering Spare Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41
1.1.0 Alfa Laval Service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41
Index
4 O26WE08TOC.fm
Safety Instructions and Warnings
Should you need further clarification regarding this manual, do not hesitate to con-
tact your local Alfa Laval representative - or call Alfa Laval Desalt directly.
WARNING
This symbol is used to indicate the presence of a hazard which can or will
cause severe personal injury, if the warning is ignored.
CAUTION
Certain passages of the text will be marked with a caution mark. This mark
indicates the presence of hazard which will or can cause property damage
if the instructions are not observed.
NOTE
This type of instruction indicates a situation which, if not avoided, could re-
sult in damage to the equipment.
It is the owner’s and operator’s responsibility to see that any person involved
with the use or operation of this equipment follow all safety instructions.
Read all safety instructions carefully and insist that they will be followed by
those working with you and for you. Not following the instructions may cause
severe personal injury or damage the equipment beyond repair.
Do not allow this equipment to be used if it is faulty or the operator does not
understand the proper use.
Samare04.fm 5
Safety Instructions and Warnings
WARNING
Freshwater must not be produced from polluted water, as the produced water can
be unsuitable for human consumption.
If manuals are translated to local language the unit comply with the EEC Machinery
Directive and EN 292-1/2 standards. For EEC land installations manuals MUST be
available in local language before installing and operating the unit.
The unit also comply with EN 50081-2 and EN 50082-2 “Industry” with regards to the
EMC directive from EEC.
WARNING
Noise hazards
• Use ear protection in noisy environments.
Crush hazards
• Use correct lifting tools.
• Do not work under hanging load.
Burn hazard
• Wear gloves to avoid burns by hot surfaces.
Cut hazards
• Wear gloves to avoid cuts by sharp edges when handling machined
parts.
• Wear helmet to avoid cuts by sharp edges during maintenance of the
equipment.
NOTE
6 Samare04.fm
System Description
The feedwater is introduced into the evaporator section through an spring loaded
valve (full open by 2 bar) orifice, and is distributed into every second plate channel
(evaporation channels).
The hot water is distributed into the remaining channels, thus transferring its heat to
the feedwater in the evaporation channels.
Having passed a demister the vapour enters every second plate channel in the top
of the condenser section.
The sea cooling water supplied to the condenser by the combined cooling/ejector
water pump distributes itself into the remaining condenser channels, thus absorbing
the heat being transferred from the condensing vapour.
From outlet side the condenser, the sea cooling water is used as jet water for the
ejector and as feed water for evaporation.
The produced freshwater is extracted by the freshwater pump and led to the fresh-
water tank.
If the salinity of the produced freshwater exceeds the chosen maximum value, the
dump valve and alarm are activated to automatically dump the produced freshwater
to the bilge.
If there are no special requirements from the authorities, the produced freshwater
can be used directly as drinking water.
Sy1jwe00.fm 7
System Description
1. Evaporator section
The evaporator section consists of a plate heat exchanger and is enclosed in
the separator vessel.
2. Separator vessel
The separator separates the brine from the vapour.
3. Condenser section
Just like the evaporator section the condenser section consists of a plate heat
exchanger enclosed in the separator vessel.
5. Ejector pump
Normally, the ejector pump is delivered by Alfa Laval, and the ejector pump is
a single-stage centrifugal pump. This pump supplies the condenser with sea
cooling water and the brine/air ejector with jet water as well as feed water for
evaporation.
6. Freshwater pump
The freshwater pump is a single-stage centrifugal pump. The freshwater pump
extracts the produced freshwater from the condenser, and pumps the water to
the freshwater tank.
7. Salinometer
The salinometer continuously checks the salinity of the produced water. The
alarm set point is adjustable.
8. Control panel
Normally, the control panel is delivered by Alfa Laval. It contains motor starters,
running lights, salinometer, contacts for remote alarm and is prepared for start/
stop.
8 Sy1jwe00.fm
Operating Instructions
WARNING
Freshwater must not be produced from polluted water, as the produced water will be
unsuitable for human consumption.
CAUTION
1.1.0 Starting
1. Open valves on the suction and discharge side of the ejector pump
PU-SC-01.
Pressure at combined brine/air ejector inlet minimum 300 kPa (3.0 kp/cm²).
Back pressure at combined brine/air ejector outlet maximum 60 kPa (0.6 kp/
cm²).
1.1.1 Evaporation
When there is a minimum of 90% vacuum (after maximum 10 minutes).
Opjwe00.fm 9
Operating Instructions
7. Start hot water supply to distiller by adjusting bypass valve or hot water pump
if any, step-wise 10°C, until the desired jacket water temperature is reached.
The boiling temperature now rises, while the obtained vacuum drops to approx.
85%.
1.1.2 Condensation
After approx. 3 minutes the boiling temperature will drop again, and normal vacuum
is reestablished.
9. Switch on salinometer.
NOTE
The freshwater pump discharge pressure will be between 120 and 160 kPa
(1.2 - 1.6 kp/cm²).
After starting the freshwater pump the flow sight glass in the air suction pipe must
be empty.
CAUTION
If water remains in the flow sight glass in the air suction pipe, please refer
to “Trouble shooting”.
In order to obtain the specified flow of hot water, it is necessary to adjust the bypass
valve until desired flow is achieved.
10 Opjwe00.fm
Operating Instructions
Where:
Opjwe00.fm 11
Operating Instructions
7. Close valves on the suction and discharge side of the ejector pump.
CAUTION
All valves must be shut, while the distiller is out of operation. Except air
screw.
12 Opjwe00.fm
Maintenance
The maintenance schedule on the following pages will tell you how often service
should be performed on the main components.
As the actual operating conditions of the plant are of major influence on the life time,
the overhaul dates are not obligatory but only recommended intervals.
When the plant has been in operation for a longer period of time and experience has
been established as to the actual performance, it will be possible to adapt the main-
tenance schedule.
Majwpe00.fm 13
Maintenance
CAUTION
NOTE
14 Majwpe00.fm
Maintenance
2. Loosen the
in plate stack gradually, so that no nut is carrying the entire load alone.
NOTE
If some of the gaskets come loose on removing plate stack, please see
section 1.5.2
4. Submerge plates completely in a hot, inhibited acid bath at maximum 50ºC. For
further instructions see “Chemical dosing of scale control chemicals”.
WARNING
Always follow carefully the suppliers instructions when using inhibited ac-
ids.
5. Examine plates and gaskets for possible damage, and remove damaged plates
and/or replace damaged gaskets.
6. If a defective plate is found, remove the plate together with one of the adjacent
plates.
Majwpe00.fm 15
Maintenance
NOTE
CAUTION
The ES and EE plate cannot be removed but must always be replaced with
a corresponding plate.
The evaporator section is pressure tested by letting hot water circulate through
the section with bypass valve for hot water in normal running position.
10. When the evaporator section is found to be tight, close front cover and tighten
bolts.
2. Loosen the
in plate stack gradually, so that no nut is carrying the entire load alone.
16 Majwpe00.fm
Maintenance
NOTE
If some of the gaskets come loose on removing plate stack, please see
section 1.5.2
4. Scrub plates with a soft brush and plain hot water at maximum 50ºC.
5. Examine plates and gaskets for possible damage, and remove damaged plates
and/or replace damaged gaskets.
6. If a defective plate is found, remove the plate and one of the adjacent plates.
NOTE
CAUTION
The KS and KE plate cannot be removed but must always be replaced with
a corresponding plate.
The condenser section is pressure tested by letting sea water from the com-
bined cooling water/ejector pump circulate through the section.
Majwpe00.fm 17
Maintenance
CAUTION
Before starting the combined ejector/cooling water pump, the feed water
must be sealed off.
10. When the condenser section is found to be tight, close front cover and tighten
bolts.
12. Do not forget to remove the feed water sealing as mentioned above.
If the gasket cannot come off directly, heat the back of the gasket groove with a
hot-air blower or butane gas burner.
You will obtain a suitable temperature, if the flame is held 10 to 15 cm behind the
plate.
WARNING
1.5.2 Cleaning
Charred or loose glue and rubber remains must be removed, e.g. using a rotating
stainless steel brush. The width should be adapted (Ø40-50 mm, width 8-10 mm).
Thin layers of glue which are difficult to remove, may remain.
Clean the gasket groove with a clean cloth, dipped in a solvent (acetone, methyl eth-
yl ketone, trichlorethylene etc.).
18 Majwpe00.fm
Maintenance
WARNING
Gaskets, that have loosened, can be glued on. Clean gasket groove carefully with a
sharp tool. Then clean the loose part of the gasket with emery cloth or sandpaper.
Finally clean groove and gasket with a solvent, and glue.
Short gaskets should be stretched before being fitted into the groove.
Long gaskets should be fitted into the grooves at the plate ends first and then grad-
ually be pushed into the groove towards the middle.
Majwpe00.fm 19
Maintenance
20 Majwpe00.fm
Chemical Dosing of Scale Control Chemicals
In order to effectively prevent scaling the operators must be aware of the factors in-
fluencing the scale formation.
If the feedwater ratio is reduced, the concentration will rise in the plant subsequently
resulting in scale formations.
Two things may shift the feedwater ratio: first of all direct adjustment of the feedwater
system, and secondly exceeding the maximum freshwater production laid out for the
plant. The operators must observe the following rules at all times.
CAUTION
DO NOT adjust feedwater system. Feedwater pressure min. 3.0 max. 4.0
bar g.
Cdgnpe00.fm 21
Chemical Dosing of Scale Control Chemicals
CAUTION
We recommend that you do not operate the freshwater distiller without rec-
ommended chemical dosage at boiling temperatures above 45°C. Even at
lower temperatures it can be recommended.
Use a fully soluble scale inhibitor, e.g. on polymer basis. The following products can
be recommended:
HEXAMETHAPHOSPHATE
1. Mix the required quantity for 24 hours operation in the tank according to mak-
er’s instructions.
2. Adjust flowmeter to cover the maximum freshwater output from the distiller.
22 Cdgnpe00.fm
Chemical Dosing of Scale Control Chemicals
WARNING
1 USE eye protection and gloves. Avoid direct skin contact, eye contact
or contact with clothes.
3 If chemicals are spilled on clothes, rinse with water and dispose off
clothes.
4 If chemicals are spilled on the floor, rinse with water and suck remain-
ing chemicals off with sand. Clean the spot immediately afterwards.
6 If eyes get in contact with the chemicals, rinse for at least 20 minutes.
IMMEDIATELY SEEK MEDICAL ATTENTION.
Cdgnpe00.fm 23
Chemical Dosing of Scale Control Chemicals
24 Cdgnpe00.fm
Trouble-Shooting
Too low ejector pump pres- See instructions for “Low Sea
sure. Cooling water/Ejector pump
flow / pressure”, below.
Trw26e03.fm 25
Trouble-Shooting
Low Sea Cooling water/Ejector Too low ejector pump pres- Clean, or replace pressure
pump flow / pressure. sure. gauge.
Minimum pressure 300 kPa
(3.0 kp/cm²) (43.5 PSI). Suction strainer blocked. Clean suction strainer.
At inlet side of ejector.
Valves on suction or pressure Examine and overhaul defec-
pipe defect. tive valves.
Sight glass overflow. Normal Suction pipe leakage. Check suction pipe especially
back pressure for freshwater unions and connections. Re-
pump is 120 - 160 kPa (1.2 - pair.
1.6 kp/cm²) (17.4 - 23.2 PSI).
Except for JWP-16-C40 gener- Mechanical seal in freshwater Replace mechanical seal.
ator type, where the max. back pump defect.
pressure is 80 kPa (0.8 kp/cm²)
(11.6 PSI). Impeller / seal ring in freshwa- Check pump maximum clear-
ter extraction pipe defect. ance See “Maintenance of
Freshwater Pump”
Salinity too high (more than 2.0 Demister not fitted correctly. Check that demister is fitted
ppm). against baffle and front cover.
26 Trw26e03.fm
Trouble-Shooting
Insufficient brine extraction - Ejector pump pressure too See special instructions for
brine level in sight glass higher low. “Low Sea Cooling water/Ejec-
than 20 mm. tor pump flow / pressure”,
above.
Frequent refill of freshwater Leakage in evaporator sec- Open distiller and pressure test
expansion tank due to loss of tion. condenser. Max. 600 kPa (6.0
hot water. kp/cm²) (87 PSI).
If there is a defective plate, re-
move together with adjacent
plates assemble plate stack
according to new plate number
with reduced assembly mea-
surements. Check plate gas-
kets and replace, if necessary.
Trw26e03.fm 27
Trouble-Shooting
28 Trw26e03.fm
Maintenance of Freshwater Pump
2. Lift motor with pump cover 4 and impeller 2 clear of pump casing 1.
7. Inspect the ceramic ring, the carbon ring and the spring.
Mapvfe00.fm 29
Maintenance of Freshwater Pump
10. Inspect impeller and the drilled sealing water channel for clogging, and clean.
11. Remember to replace gasket 3.
1.1.1 Clearance
In connection with the inspection be sure to measure the impeller and wear ring 17
in order to secure that the clearance is no more than 0.5 mm on the diameter.
CAUTION
The pump shaft 11 must only be dismantled, if pump shaft or electric mo-
tor bearing has to be replaced.
3. Carefully insert two screw drivers behind the pump shaft, and loosen it.
If the pump shaft does not come loose, use the special dismantling tools shown
below.
30 Mapvfe00.fm
Maintenance of Freshwater Pump
The tool consists of a pipe (A), a disc (B) with hole for the screw (C) and a nut
(D), washer (E).
Please note that the length L must be longer than the length l.
Place pipe around the shaft. Fasten the screw with nut and washer into the
threaded hole (M12) on the shaft end.
CAUTION
5. Make sure that the pump shaft fits the motor shaft without any obstructions, be-
fore final shaft fitting as follows:
• Tap onto the end of the pump shaft slightly with a RUBBER hammer.
Mapvfe00.fm 31
Maintenance of Freshwater Pump
NOTE
The torque should be 5 Nm (0.5 kpm) and the maximum wobble 60 µ.m.
32 Mapvfe00.fm
Maintenance of Ejector Pump
Motor with motor bracket 6, pump cover 2, and impeller 5 can now be lifted
clear of the pump casing 1.
3. Remove impeller.
Macnle00.fm 33
Maintenance of Ejector Pump
NOTE
If not, you can fit dismantling screws into the two threaded holes in the im-
peller.
4. Remove the key 26 and the mechanical seal 8 (including spring holder, spring
and carbon ring).
5. Inspect the ceramic ring, the carbon ring and the spring. Replace, if necessary
In order to make it easier to assemble the mechanical seal, the shaft and ring
seat may be greased with glycerine. Please also refer to separate instructions
for mechanical seal delivered together with the seal.
• After fitting the ceramic ring, fit pump cover 2 to motor bracket 6.
1.1.1 Clearance
In connection with the inspection, the impeller 5 and wear rings 10 are measured
in order to secure that the clearance is not larger than stated in the diagram below.
34 Macnle00.fm
Maintenance of Ejector Pump
CAUTION
The pump shaft may only be dismantled, if pump shaft or bearings, in the
electric motor have to be replaced.
Macnle00.fm 35
Maintenance of Ejector Pump
2. Remove shaft 4. Normally this can be done without using dismantling tools.
CAUTION
3. Fit shaft 4.
4. In order to make sure that the coupling is fitted correctly, tap slightly at the shaft
end with a RUBBER hammer.
36 Macnle00.fm
Salinometer
Frequency 50/60 Hz
Power consumption Salinometer 10 VA.
2. Select correct voltage select according to the main supply voltage 115 V or 230
VAC.
Salise00.fm 37
Salinometer
Green pilot LED should light up. Dot. Bar displays the measured salinity.
WARNING
The salinometer must be tested at least once a month, and the electrode
unit must be cleaned.
If the alarm level is less than 10 ppm, the salinometer will give an alarm.
Cancel buzzer and external alarm system by switching “Sec. Alarm” off. Solenoid
valve is not affected.
Switch “Sec. Alarm” on as soon as the salinity is normal again; i.e. when the two red
38 Salise00.fm
Salinometer
1.3.3 Maintenance
CAUTION
Remove electrode unit and inspect/clean after every 1000 hours of opera-
tion. Use a clean and dry rag. Avoid touching the electrodes with the fin-
gers.
Salise00.fm 39
Salinometer
40 Salise00.fm
Spare Parts
1. Serial number.
2. Capacity.
3. Designation.
5. Position number.
6. Article number.
In order to identify article numbers, please refer to FWG Order Specification and oth-
er drawings.
2. Check spare part drawing and item list with corresponding article number to
identify the item to be ordered.
DO NOT hesitate to contact your Alfa Laval representative if you have any ques-
tions, problems or require spare parts.
Spmare01.fm 41
Spare Parts
42 Spmare01.fm
Index
A
Adjustment of alarm level . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38
Adjustment of hot water flow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
Adjustment of sea cooling water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
Alfa Laval service . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41
C
Chemical dosage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
Clearance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 34
Condensation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
D
Dismantling pump shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 36
E
Ejector Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 33
Evaporation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
F
Feed water ratio . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
Fitting new gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19
Freshwater Pump Types PVVF 1525-1532-2040 . . . . . . . . . . . . . . . . . . . . . . . . page 29
Freshwater quality . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
I
Installation (for DS-20) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
Instructions for use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38
L
Long term standstill . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12
M
Main components . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 8
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 39
Maintenance of condenser section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
Maintenance of ejector pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 33
Maintenance of evaporator section . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Maintenance of Freshwater pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 29
Maintenance of freshwater pump types PVVF 1525-1532-2040 . . . . . . . . . . . . . page 29
Maintenance of separator vessel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
O26WE08IX.fm 43
Index
O
Ordering spare parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41
Overhaul intervals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Overhaul of the pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 33
P
Preparation of new gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 19
Prevention of scaling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 21
R
Removal of old gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
Renewal of plate heat exchanger gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 18
S
Safety instructions and warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Safety precautions with the use of chemicals . . . . . . . . . . . . . . . . . . . . . . . . . . . page 23
Salinometer type DS-20 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
Scale inhibitor dosage equipment for feed water . . . . . . . . . . . . . . . . . . . . . . . . page 22
Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 41
Starting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
Starting and stopping procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
Stopping Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 9
Stopping the plant . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 11
System description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
T
Technical specification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 37
Telefax . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Telephone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Test sheet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
Testing the instrument . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 38
Trouble shooting table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 25
W
Warning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5
Why you need to perform regular maintenance duties . . . . . . . . . . . . . . . . . . . . page 13
Working principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 7
44 O26WE08IX.fm
SOLD BY / 販売