0% found this document useful (0 votes)
1K views6 pages

QJ - Warning Codes (Blue) : Code 1

The document describes 34 warning codes for a Sandvik QJ feeder. The codes indicate issues like low conveyor speeds, pull stops activated, high hydraulic oil temperature, radio faults, low fuel or urea levels. For each code there is a description, criteria to trigger the warning, the associated machine action, and steps to troubleshoot the issue.

Uploaded by

avtonika38
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
1K views6 pages

QJ - Warning Codes (Blue) : Code 1

The document describes 34 warning codes for a Sandvik QJ feeder. The codes indicate issues like low conveyor speeds, pull stops activated, high hydraulic oil temperature, radio faults, low fuel or urea levels. For each code there is a description, criteria to trigger the warning, the associated machine action, and steps to troubleshoot the issue.

Uploaded by

avtonika38
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

Sandvik QJ Warnings - DP600 V1.08 MC88 V1.

07

QJ – Warning Codes (Blue)

Code 1
Description Main Conveyor Speed Low
Criteria Main conveyor speed is less than ‘Main Conveyor Speed Warning’ Set
Point

Action Feeder stopped

Troubleshooting Ensure belt speed is above the set point


Ensure speed wheel signal is being received by controller,
investigate speed wheel circuit

Code 2
Description Side Conveyor Speed Low
Criteria Side conveyor speed is less than ‘Side Conveyor Speed Warning’ Set Point

Action Feeder Stopped

Troubleshooting Ensure belt speed is above the set point


Ensure speed wheel signal is being received by controller,
investigate speed wheel circuit

Code 6
Description Main Conveyor Pull Stop
Criteria Main conveyor pull stop signal is low

Action Main conveyor and feeder stopped

Troubleshooting Ensure pull stop is reset,


Investigate pull stop circuit, ensure input to controller is high

1
Sandvik QJ Warnings - DP600 V1.08 MC88 V1.07

Code 10
Description Hydraulic Oil Temperature High
Criteria Hydraulic oil temperature is above the warning level

Action Feeder Stopped

Troubleshooting Ensure Oil Temperature is lower than the warning level


Investigate oil temperature circuit,
check sensor impedance,
check 5v supply to sensor

Code 12
Description Track Radio Joy Stick Fault
Fault Criteria Joystick fault message received from radio received

Action Prevents radio tracking / Radio functions

Troubleshooting Ensure radio transmitter battery is charged,


Ensure radio transmitter is in serviceable condition

Code 13
Description Radio Unavailable
Criteria No valid CAN messages received from radio receiver

Action Prevents radio tracking / Radio functions

Troubleshooting Ensure receiver is powered and connected


Investigate CAN connection

Code 14
Description No Radio Signal
Criteria Low radio signal message received from radio receiver

Action Prevents radio tracking / Radio functions

Troubleshooting Ensure radio battery is charged


Ensure handset is live – indicated by flashing green led
Ensure antenna is connected and in good condition

2
Sandvik QJ Warnings - DP600 V1.08 MC88 V1.07

Code 15
Description Dog Lead Fault
Criteria Forward / Reverse signals form tracking handset out of range

Action Prevents manual tracking

Troubleshooting Ensure signals are correct,


Investigate tracking handset circuit

Code 18
Description Side Conveyor Pull Stop
Criteria Side conveyor pull stop input is low

Action Feeder stopped / Conveyor stopped

Troubleshooting Ensure pull stop is reset


Ensure pull stop input is high
Investigate pull stop circuit

Code 20
Description Low Urea Level
Fault Criteria Urea level is below the ‘Urea Level Warning’ set point

Action Feeder stopped

Troubleshooting Ensure Urea level is above the minimum level

Code 21
Description Toggle Overcharging
Criteria Toggle charge output has remain on for an extended period of time

Action Non - reference only

Troubleshooting Investigate toggle changing circuit

3
Sandvik QJ Warnings - DP600 V1.08 MC88 V1.07

Code 22
Description Warning High Load
Criteria Crusher drive pressure is above ‘Drive pressure warning’ set point for
‘Drive pressure warning time’ set point

Action Feeder stopped

Troubleshooting Ensure drive pressure remains below the set point


Investigate the crusher pressure transducer circuit

Code 23
Description Fuel Level Low
Criteria Fuel level is less than the ‘Fuel level warning’ set point

Action Feeder stopped

Troubleshooting Ensure fuel level is above the set point,


Investigate the fuel level sensor circuit

Code 24
Description High Soot Load
Criteria DPF soot load is above the ‘Soot load warning’ set point

Action Feeder stopped

Troubleshooting Ensure soot load is below the warning level,


Investigate other active engine alarms that may prevent regeneration,
Consult CAT

Code 26
Description Air filter Restriction
Criteria Engine air filter restriction switch is closed

Action Feeder Stopped

Troubleshooting Ensure air filter restriction switch is reset

4
Sandvik QJ Warnings - DP600 V1.08 MC88 V1.07

Code 27
Description Greaser Fault
Criteria Auto lubrication fault input is high

Action Feeder Stopped

Troubleshooting Ensure auto lubrication fault is reset


Investigate auto lubrication system / circuit

Code 28
Description Low Crusher Speed
Criteria Crusher speed is below ‘Crusher Minimum Speed’ set point

Action Feeder stopped

Troubleshooting Ensure crusher speed remains above warning level


Investigate crusher speed sensor circuit

Code 29
Description Main Conveyor Output Fault
Criteria Main conveyor solenoid output is shorted to ground

Action Non - Reference only

Troubleshooting Investigate main conveyor solenoid circuit

Code 30
Description Crusher Forward Output Fault
Criteria Crusher forward output is shorted to ground

Action Non – Reference only

Troubleshooting Investigate crusher forwards output circuit

5
Sandvik QJ Warnings - DP600 V1.08 MC88 V1.07

Code 31
Description Crusher Reverse Output Fault
Criteria Crusher reverse output is shorted to ground

Action Non – Reference only

Troubleshooting Investigate crusher reverse output circuit

Code 32
Description Side Conveyor Output Fault
Criteria Side Conveyor output is shorted to ground

Action Non – Reference only

Troubleshooting Investigate side conveyor output circuit

Code 34
Description Fuel Level Sender Unavailable
Criteria Fuel level sensor input out of range

Action Non – Reference only

Troubleshooting Investigate fuel level sender circuit,


Ensure impedance is between 10 & 180 ohms

Code 35
Description Tail Conveyor Material Level High
Criteria Main conveyor level sensor signal is below the desired level

Action Feeder stopped

Troubleshooting Ensure level of material is below set point,


Investigate main conveyor level sensor circuit