Training Information:
Technicians with prior certification on the G056/G058/G073/G074/G091/G094/G095 will be automatically
certified on the G113/G114/G116 upon receipt and review of the G113/G114/G116 documentation update
package. A CBT will be available for technicians without prior certifications.
Documentation:
Description EDP Code
Self-Pace CBT Training Package 001049MIU
If you have any questions regarding this or any other training, please contact the Service Education and
Development Division at (973) 882-5797.
Product Concept:
The G112/G113/G116 are the next generation of B/W printers in the 28-35ppm print ranges and are
replacements for the G094/G095/G091 Series. The G116 runs at 35ppm with a maximum sheet feed
size of 11x17. The G112/G113 runs at 28ppm, with a maximum sheet feed size of 8.5x14. All three
models have duplex, paper tray, and envelope feeder options.
Product Type:
Digital B/W Printer
G116
G113/G114
A
B
Item Product
Item Common / Unique Options
Index Code
A Mainframe G116
B Duplex Unit – AD610 G806 U
C Paper Feed Unit - Type 610 G399 U
D Envelope Feeder – Type 610 G807 U
1 802.11b Interface Unit – Type F * G813 U
2 1394 Interface Unit – Type 4510 * G336 C (G065,G073/G074,G080)
3 Bluetooth Unit – Type C * G354 C (G080,B079/B082,G094/G095)
4 Memory Unit – Type C 256MB G332 C (G073/G074)
5 Network Data Protection Unit Type C G880 U
6 HDD – Type 2600 G575 C (G073/G074)
* Only 1 I/F board can be installed.
A C
D
B
A C
D
B
G116
CPU Speed 372Mhz
Memory Capacity Standard –128MB SDRAM
Max 256MB
Print (Engine) Speed 35ppm/LT – LEF
Resolution 200/300/600/1200 dpi
Interface Bi-centronics (IEEE 1284) - Standard
USB 2.0 - Standard
NIB 10/100baseTX - Standard
IEEE 802.11b – Option
IEEE 1394 – Option
Bluetooth – Option
Printer Language PCL5e/6, RPCS, PS3, PDF Direct Print
Fonts PCL – 35 Intelli fonts. 10 TrueType fonts, 1 bitmap font.
PS – 136 Type1 fonts.
DESS Network Data Protection Unit
G112/G113
CPU Speed 400Mhz
Memory Capacity G112: Standard – 64MB SDRAM
Max 320MB
G113: Standard – 128MB SDRAM
Max 256MB
Print (Engine) Speed 27ppm/LT – LEF
Resolution 400/600/1200 dpi
Interface Bi-centronics (IEEE 1284) - Standard
USB 2.0 - Standard.
NIB 10/100baseTX G112 - Option, G113 - Standard.
IEEE 802.11b– Option
Bluetooth – Option
IEEE 1394 – Option
Printer Language PCL5e/6, RPCS, PS3, PDF Direct Print
Fonts PCL – 35 Intelli fonts. 10 TrueType fonts, 1 bitmap font.
PS – 136 Type1 fonts.
DESS* Network Data Protection Unit*
Software Description
Font Manager • A font management utility with screen fonts for
(Win95/98/ME, NT4, 2000, XP, Server 2003) the printer.
Smart Net Monitor for Admin • A printer management utility for network
(Win95/98/ME, NT4, 2000, XP, Server 2003) administrators.
• Setup utilities are also available.
Smart Net Monitor for Client • A printer management utility for client users.
(Win95/98/ME, NT4, 2000, XP, Server 2003) • A utility for peer-to-peer printing over a NetBEUI
or a TCP/IP network.
• A peer-to-peer print utility over a TCP/IP
network. This provides parallel printing and
recovery printing features.
Printer Utility for Mac • This software provides several convenient
functions for printing from Macintosh clients.
PS Descriptions • PDD for Mac
IEEE1394 Utility (Win2000, XP) • This utility solves problems with Windows 2000.
• Menu -> List/Test Print -> Config. Page. Pages Printed. Total counter limit 6 digits.
• Total counter can be displayed and printed only if the meter change mode is set to yes in SP 5-
930. Menu --> (counter displayed) Enter --> Arrow Down (print is displayed) --> Enter.
• Total counter can also be displayed in SP 7-993; this counter includes all prints including service
reports.
• In the G116 only, the SP 5-104 specifies whether the counter is doubled for 11 x 17. There is no
extra counter for these reading, it is added to the total.
Installation Requirements:
Temperature Range: 10° C to 32° C (50° F to 90° F)
Humidity Range: 15% to 89% RH
Ambient Illumination: Less than 2,000 lux (do not expose to direct sunlight)
Ventilation: 3 times/hr/person
Ambient Dust Less than 0.10 mg/m³ (2.7 x 10/6 oz/yd³)
Avoid areas exposed to sudden temperature changes:
• Areas directly exposed to cool air from an air conditioner
• Areas directly exposed to heat from a heater
Do not place machine where it will be exposed to corrosive gas or vapor. Some Blue Print machines use an
ammonia based development process, which may produce a corrosive vapor.
Do not install the machine at any location over 2,500m (8,125 ft.) above sea level.
Place the machine on a strong and level base. Inclination on any side should be no more than 5mm (0.2”)
Do not place the machine where it may be subject to strong vibrations.
Machine level • Front to back: within 5mm (0.2”) of level
• Right to left: within 5mm (0.2”) of level
Power Requirements:
Installation Times:
G116:
All units are user installable.
Qualified Technician - 30minutes for Full system: Mainframe, 2 PFUs, Duplex Unit, and no connectivity
options.
G112/G113:
All units are user installable.
Qualified Technician - 30 minutes for Full system: Mainframe, 2 PFUs, Duplex Unit, and no connectivity
options.
G116:
Dimensions (W x D x H): 18.8”x17.2/22.6”x13.5”
Weight: 44lbs
G112/G113:
Dimensions (W x D x H): 15.3”x17.2/20.0”x13.6”
Weight: 33lbs
PM Table:
G116 Main Frame:
Symbol key: C: Common, U: Unique
Q’ty/ PM Unique or
Part Number Description
Unit Interval Common
Paper Feed
G0523112 Paper Feed Roller 1 90K C (G091)
G0883135 Friction Pad 1 90K C (G091)
Around to Drum
G1116256 Transfer Roller 1 90K U
Fusing Unit and Paper Exit
G1114063 Hot Roller 1 90K U
G0884656 Pressure Roller 1 90K C (G091)
G0524624 Hot Roller Stripper Pawls 5 90K C (G091)
G1114064 Fusing Thermistor 1 90K U
G0524618 Bushing - Fusing Roller 2 90K C (G091)
G0524665 Bushing - Fusing Pressure 2 90K C (G091)
G1114117 Fusing Assy 1 90K U
Customers can replace all PM items using the maintenance kit. When the maintenance counter reaches
90K, "Replace Maintenance Kit" is displayed. After replacing the parts in the maintenance kit, the
machine automatically resets the PM (fusing) count. Service technicians, as necessary, perform all other
replacement items.
PM Table:
Q’ty Unique or
Part Number Description PM Interval
/Unit Common
G0523103 Paper Feed Roller 1 90K C (G091)
G0963066 Friction Pad 1 90K C (G091)
Customers can replace all PM items using the maintenance kit. When the maintenance counter reaches
90K, "Replace Maintenance Kit" is displayed. After replacing the parts in the maintenance kit, the
machine automatically resets the PM (fusing) count. Service technicians, as necessary, perform all other
replacement items.
Name Contact
Technical Services Call Center (Hotline) Ricoh: (800) 537-4264
Savin/Gestetner: (800) 291-6044
Lanier: (800) 333-3147
Application Help Desk (Software Issues) Ricoh Phone Card: 2 Call - 000781MIU, 5 Call - 000900MIU
Savin Phone Card: 2 Call - 12992, 5 Call - 12993
Gestetner Phone Card: 2 Call - 12994, 5 Call - 12995
National Reclamation Center (800) 557-4264 http://www.nrc-usa.com
Technology Solutions Center Web Site http://www.tscweb.net
Ricoh Web Site http://www.ricoh-usa.com/
Savin iLINC Web Site http://w3.savin.com
Gestetner ILINE Web Site http://W3.gestetnerusa.com
Lanier Web Site http://www.lanier.com
Headquarter Web Sites Ricoh Corporation: http://www.ricoh-usa.com
Savin Corporation: http://www.savin.com
Gestetner Corporation: http://www.gestetnerusa.com/
Fax On Demand (973) 808-3590
Material Safety Data Sheets (800) 336-MSDS (6737)
Eastern Training Center (973) 808-7646 http://www.ricohuniversity.com
Western Training Center (714) 566-3692 http://www.ricohuniversity.com
Lanier Education Center (678)-824-3000
Special Tools:
Unique or Common
U: Unique for this model
C: Common with listed model
Item Part Number Description Q’ty Unique or Common
1 A0069104 Scanner Positioning Pin (4pcs/set) 1 C (General)
2 VSSM9000 Digital Multimeter – FLUKE 87 1 C (General)
3 B6455010 SD-Card: Assembly 1 C (B070) G113/G116 only
4 B6456700 SD-Card: Adapter: BN-SDAA2 1 C (B070) G113/G116 only
5 B6456800 SD-Card: USB: Writer BN-SDCE2 1 C (B070) G113/G116 only
6 N8036701 Flash Memory Card – 4MB 1 C (General) G112 only
7 N8031000 Flash Memory (PCMCIA) Card Case C (General) G112 only
8 A2309354 Memory Card Explorer Kit 1 C (General) G112 only
9 G0219350 Loop Back Connector 1 C (General)
Mainframes:
Product Code EDP Code Lanier ID Item Model Name
402338 35ppm
G116 - RICOH Aficio AP610N
Ricoh Mainframe w/NIB
Savin MLP35n
402341 35ppm
G116 479-1558 Gestetner P7535n
Savin/Gestetner Mainframe w/NIB
Lanier LP135n
402348 27ppm
G112 - RICOH Aficio AP410
Ricoh Mainframe
SAVIN MLP28
402351 27ppm
G112 479-1556 Gestetner P7527
Savin/Gestetner Mainframe
Lanier LP128
402353 27ppm
G113 - RICOH Aficio AP410N
Ricoh Mainframe /NIB
SAVIN MLP28n
402356 27ppm
G113 479-1557 Gestetner P7527n
Savin/Gestetner Mainframe w/NIB
Lanier LP128n
* All models include a starter cartridge with yield of 6K (LT/5% coverage)
G116 Options
G112 Options
Note 1: Serial number Q03492xxxxx or older can not be used on this model unless Main PCB is replaced,
due to change of engine speed in the G112/G133 from the G094/G095.
G116
EDP Product
Item Name Target Yield
Code Code
Gestetner
P7535n
20K prints/ctrg.
Starter: 6K
AIO 400789 Toner AIO Type 2602 9876 prints/ctrg.
A4 (8.5”x11”)/
5% Chart
Maintenance Kit 402346 MAINTENANCE KIT Type 610 402346 90K prints
Lanier
LP135n
20K prints/ctrg.
Starter: 6K
Lanier Toner Cartridge for
AIO 402854 480-0094 prints/ctrg.
AP2610/AP2610N/LP032/LP135n
A4 (8.5”x11”)/
5% Chart
Maintenance Kit 402346 MAINTENANCE KIT Type 610 481-0880 90K prints
Ricoh
Aficio AP610N
20K prints/ctrg.
RICOH LP TONER CARTRIDGE Starter: 6K
AIO 400759 TYPE 115 BLACK for G795 prints/ctrg
AP2600/2610/600N/610N A4 (8.5”x11”)/
5% Chart.
Maintenance Kit 402346 MAINTENANCE KIT Type 610 G263 90K prints
Savin
MLP32
20K prints/ctrg.
Starter: 6K
Toner AIO Type 2602 for Savin
AIO 400789 9876 prints/ctrg.
models MLP26/MLP32/MLP35
A4 (8.5”x11”)/
5% Chart
Maintenance Kit 402346 MAINTENANCE KIT Type 610 402346 90K prints
G112/G113
Product
Item EDP Code Name Target Yield
Code
Gestetner
P7527/P7527n
15K prints/ctrg.
Starter: 6K
Toner AIO Type 2503
AIO 400946 9894 prints/ctrg.
Black
A4 (8.5”x11”)/ 5%
Chart
MAINTENANCE KIT
Maintenance Kit 402359 402359 90K prints
Type 410
Lanier
LP128/ LP128n
15K prints/ctrg.
Starter: 6K
Black Toner for
AIO 400949 480-0192 prints/ctrg.
LP026/LP128/LP128n
A4 (8.5”x11”)/ 5%
Chart
MAINTENANCE KIT
Maintenance Kit 402359 481-0879 90K prints
Type 410
Ricoh
Aficio AP410/AP410N
15K prints/ctrg.
RICOH LP TONER
Starter: 6K
CARTRIDGE TYPE
AIO 400942 G216 prints/ctrg.
120 BLACK for
A4 (8.5”x11”)/ 5%
AP400/AP410
Chart
MAINTENANCE KIT
Maintenance Kit 402359 G263 90K prints
Type 410
Savin
MLP28/ MLP28n
15K prints/ctrg.
Starter: 6K
Toner AIO Type 2503
AIO 400946 9894 prints/ctrg.
Black
A4 (8.5”x11”)/ 5%
Chart
MAINTENANCE KIT
Maintenance Kit 402359 402359 90K prints
Type 410
G116
Part Number Description Quantity Remarks
G0884611 Fusing Thermostat 1 Replace as necessary
G0885544 Fusing Heater Lamp 1 Replace as necessary
G1114064 Fusing Thermistor 1 Replace as necessary
G0965300 Bias Power Pack 1 Replace as necessary
G0885212 Power Supply Unit 1 Replace as necessary
G0915701 Main PCB 1 Replace as necessary
G1115121 Engine PCB 1 Replace as necessary
G0523103 Paper Feed Roller 1 90K
G0963066 Friction Pad 1 90K
G112/113
Part Number Description Quantity Remarks
G0964611 Fusing Thermostat 1 Replace as necessary
AX440178 Fusing Heater Lamp 1 Replace as necessary
G0965501 Fusing Thermistor 1 Replace as necessary
G0965300 Bias Power Pack 1 Replace as necessary
GZ230019 Power Supply Unit 1 Replace as necessary
G1125317 G112 Controller PCB 1 Replace as necessary
G1135317 G113 Controller PCB 1 Replace as necessary
G1295102 Engine PCB 1 Replace as necessary
G0523103 Paper Feed Roller 1 90K
G0963066 Friction Pad 1 90K
Firmware Structure
Model Firmware Type
G112 Controller, 3 PCMCIA Cards required
G112 Controller 1, Platform & Rescue
G112 Controller 2, Printer
G112 Controller 3, Web Support & Network
G112 Engine, 1 PCMCIA card required
G113, G116 System, SD Card
G113, G116 Printer, SD Card
G113, G116 Websys, SD Card
G113, G116 NCS, SD Card
G113, G116 Netfile, SD Card
G113, G116 Font, SD Card
G113, G116 Engine, SD Card
G113 G116 DESS, SD Card
Branding:
Ricoh version machines: No branding necessary.
Savin/Gestetner/Lanier: You must adhere the model label (provided) to the front cover and set the Plug
and Play name with SP 5-907 (SP available to technician only).