Cleaning Validation Protocol
Cleaning Validation Protocol
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
PROTOCOL
FOR
CLEANING VALIDATION
PRODUCTS
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
INDEX
PROTOCOL APPROVAL
This protocol describes the procedure to be followed & test to validate the cleaning method of product
contact part of equipment.
This protocol has been prepared, checked and approved for implementation by the following
personnel.
Prepared By
Executive-Quality Assurance
Checked By
Head-Production
Head-Quality Control
Approved By
Authorized By
Director - Technical
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
1.0 Introduction
1.1 Philosophy
Psychotropic India Limited is engaged in the operation and renovation of solid & Liquid
dosage form and External Application product manufacturing facilities at Plot No. 46 & 49,
Sector -6A, SIDCUL, Haridwar.
The cleaning validation program is designed to demonstrate that the quality features built into
facility, utilities and processes ensure that they are fully functional, remain in place and
conform to the relevant regulatory requirements.
The described herein have been designed to conform to the requirements of current Good
Manufacturing Practices as described in the directives of the World Health Organization as
well as Drug and Cosmetics Act 1940 of India.
The main aim is that once cleaning procedure is validated, the procedure will be used for the
cleaning of equipments, utensils to ensure that the subsequent product manufactured is not
contaminated by previous one and is safe and quality product.
1.2.1 The objective of cleaning validation protocol of equipment, utensils and components is to
establish sufficient documented evidence to assure that, cleaning procedures can repeatedly and
reproducibly remove residue of the subjected product- below established acceptance limit. The
acceptance limit is maximum allowable quantity of product residue, which does not affect
quality and safety of the subsequent product to be manufactured, by using same equipment and
facility.
1.2.2 To establish acceptable time limit for storage after cleaning. Equipment is not expected to be
free from all microorganisms, particularly when the final stage in cleaning does not involve
final rinsing with purified water. The objective shall be to demonstrate that there is under limit
microbial proliferation in equipments during storage. The main purpose of cleaning validation
protocol is to set up guideline to establish cleaning, sampling, testing procedure and residue
limits that are practical, achievable, and verifiable and assure safety.
2.0 Scope
This cleaning validation protocol cover validation of cleaning processes performed in the plant.
This protocol is limited to the contamination due to active material of previous product and
cleaning agent. This plan does not cover sanitation and disinfecting processes.
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
This guideline is for cleaning validation of surface directly in contact with the products/
material.
This validation programme will include:
2.1 Grouping and worst-case selection.
2.2 Selection of sampling method.
2.3 Selection of cleaning method.
2.4 Selection of analytical method.
2.5 Establishment of limit and acceptance criteria
Committee
QA Head
Production Manager
QC Head
Prepare the cleaning validation protocols, seek & obtain approval from Validation Organization
Committee.
Identify the resources required to carry out the cleaning validation study within the given
schedule.
Monitor the conduct of the study.
Collection, review of data.
Preparation of the draft report.
Preparation of final report and submit Validation Organization Committee.
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
The following flow chart represents development of cleaning validation for any particular product /
equipment
Classification of different cleaning levels
(Extent of cleaning)
NO
Approved
YES
4.0 Pre-Requirements:
For automated or clean-in-place cleaning processes, DQ, IQ, and OQ should have been
completed prior to commencement of Performance Qualification (PQ). The relative merits of
manual cleaning, Clean in Place (CIP) with manual intervention or fully automatic CIP systems
should be considered during DQ.
The test method for potential contaminants of the process operation should be developed. These
methods should be validated for their specificity, accuracy, sensitivity and limit of detection
level.
The sampling plan should be specified.
A Psychotropic India Limited has designed the multi-product facility to manufacture solid and
liquid dosage form. It may not be possible to validate cleaning process of all products
manufactured within the facility during start up of facility. In order to prioritize cleaning
validation program, a matrix approach is applied. The approach evaluates overall cleaning
requirement of the product range and concentrates the validation effort. On ‘Worst Case’
situation, the approach is applied where there are common cleaning procedures.
From Annexure I it is observed that the product having least solubility in water and higher
strength is as following.
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
From Annexure I it is observed that the product having minimum therapeutic dose / most potent
is as following.
5.6 Based on batch size of subsequent batch and product contact surface area
Product having minimum batch size & maximum surface area should be considered as ‘Worst
Case’.
Minimum batch size taken of the subsequent product manufactured in the same equipment.
Refer Annexure-I
When new product is started manufacturing and it becomes the worst case then cleaning
validation is to be done.
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
During validation of the cleaning procedure, the test methods used should be able to specifically
quantify concentrations of all compounds of interest that may be present in samples. During
subsequent verification of cleaning, non- specific methods should be employed.
6.1 Specific Analytical Test Methods
Any instrumental analytical procedures used to test samples taken during cleaning validation
studies need to be specified and sufficiently sensitive to determine the low levels of residues
typically found in samples. The methods used to test samples that will allow the equipment to be
released for manufacture of another product must themselves be validated to ensure that it meets
following requirements.
PH.
Conductivity.
Microscopy.
Titration.
Total Organic Carbon. (TOC).
TOC is likely to be most suitable for aqueous samples, and is ideal for checking for removal of
complex cleaning agents such as detergents if specificity is not a requirement. Conductivity and
pH measurements may be useful to monitor removal of any acid or alkali used as a cleaning
agent.
Whichever technique is selected, the production equipment should be visually clean.
7.0 Selection of Cleaning Method:
There are following three types of cleaning methods utilized in the drug product manufacturing
facilities:
7.1 Clean-In-Place (CIP) Method
Cleaning of the equipment is performed in place without disassembling
Cleaning process may be controlled manually or by an automated program.
Very consistent and reproducible cleaning method.
Can be validated readily.
Being a closed system visual inspection of all components is difficult.
The risk involve in manual cleaning processes is taken care of with following:
Proper wash room design with drying, protection and storage requirement.
Detailed cleaning SOP
Training / Qualification of cleaning operators
Once the cleaning method is validated, it should be ensured that the method is not changed. If
required any change in the validated cleaning method should be governed by the change
control policy and cleaning method should be re-validated.
Swab sampling
Wash Water sampling
. 4 inches 4 inches
4 inches 4 inches
Figure 1 Figure 2
Swab sampling technique for microbial evaluation: Refer relevant microbiology department SOP
for swab sampling for microbial evaluation.
9.0 Establishment of Limit and Acceptance Criteria for Maximum Allowable Carry-Over for
Previous Product Residue.
There cannot be a standard fixed limit to determine the effectiveness of a cleaning procedure, due
to the reason that variety of equipment and products are used throughout the drug product
manufacturing facility of Psychotropic India Limited. Rationale for the residue limit established
should be scientific, logical and based upon knowledge of the material. As per the guide to
inspections of Validation of Cleaning Processes the limits should be “practical, achievable and
verifiable”.
To arrive at the quantitative acceptance limit for cleaning validation of particular equipment there
has to be a good scientific and logical rationale. A quantitative limit should be based on one or
more of the following:
Therapeutic dose.
Strength of the material.
Difficulty of cleaning.
Use/ Application of the product.
Nature of other products manufactured in the equipment
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
Maximum Allowable carry over (MAC) of previous product in the subsequent product is
calculated by using the formula mentioned below,
STD x SBS x SF
MAC=
LDD
Where,
MAC= Maximum Allowable Carryover
STD= Single Therapeutic Dose of the previous product
SBS= Smallest Batch size (in Kg) of the next product to manufactured in the same
equipment
SF= Safety Factor (1/1000)
LDD= Largest Daily Dose of the next product to be manufactured in the same equipment
Assuming the contamination is present uniformly on the entire contact surface area, the
limit for one square inch of surface is calculated by dividing above MAC value by total
contact surface area in square inch.
Limit for one sq. inch= MAC/Total surface area in sq. inch
Now the limit of residual contamination for a swab area of 4” x 4” can be calculated as
follow,
The limit of residual contamination = Limit for one sq. inch x 16
R (S/T) U
The Maximum allowable residue per swab of 4 X 4 in2 can be mathematically expressed as
R = 10mg active ingredient in product A /kg of product B
S = Number of kilograms per batch of final mixture of product B
T = equipment surface area in common between products A and B expressed as square
inches.
U = 16 in.2 swab
Factor R is always 10mg of active ingredient of the product being cleaned per kilogram of
final mixture of the recipient product. This is simply 10ppm stated a different way.
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
FINAL LIMIT
This minimum value from both criteria shall be considered as acceptance limit for previous
product into subsequent product.
After considering both criteria (Dose Criteria and 10ppm Criteria), the acceptance limit for
cleaning validation shall be finalized.
The finalized limit shall be valid as long as equipment used & product combination
manufactured in the facility remains same.
If any new product is added, the cleaning limits to be recalculated.
11.0 Pre-Requirement
11.1 Requirements for chemical testing
11.1.1 Working Standard................
Lot No/Batch No.: -----------
Assay: -------------
11.1.2 Equipments
Analytical Balance
(Instrument No. -----------------)
Make: -------------
Model: ----------
HPLC
(Instrument No. -----------------)
Make: ---------
Model: ----------
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
Method Precision: Six samples set preparation of a same batch shall be analysed.
Acceptance criteria: Relative standard deviation (RSD) shall not be more than 2%.
12.3 Ruggedness: Ruggedness will be determined by analyzing sample from same batch by two
different analysts on different days. Ruggedness shall be evaluated by calculating overall
%RSD of both the analyst.
Acceptance criteria: Relative standard deviation (RSD) shall not be more than 3 %.
12.4 Limit of Quantitation: LOQ of ................ will be determined from linearity data. It will be
verified by showing precision at that concentration.
Acceptance criteria: RSD shall not be more than 10%
12.5 Limit of Detection: LOD of ................ will be determined from linearity data. It will be
verified by showing precision at that concentration.
Acceptance criteria: RSD shall not be more than 33%
12.6 Holding Time: Holding time of rinse and swab samples shall be evaluated by analyzing
sample solution at time interval 0, 3, 6, 12, 18, 24, and 36hrs.
Acceptance criteria: The Holding Time value shall not vary by more than + 10% of the Zero
time value.
12.7 Linearity:
Serial dilution of ................ standard stock preparation,
concentration ranging from 0.5 mcg/ml to 20 mcg/ml, will be prepared
and assayed by the afore-said procedure.
The linearity of the method shall be established in the range 20 ppm to
limit of Quantitation. The sample absorbance shall be plotted against
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
Calculate the API content and % recovery in each of the swabs. Calculate mean, % recovery
and RSD and tabulate the results in Annex-V.
The recovery shall not be less than 80% then it is a Very good recovery, if greeter than 65% then
recovery is good and if gretter than 50% then it is acceptable and RSD shall not be more than 10%.
16.0 Conclusion
Write down the conclusions of the data obtained as per the cleaning validation plan. The
validation report shall be evaluated by the Quality Assurance Manager and necessary
conclusions shall be drawn based on the comparison of experimental data with acceptance
criteria.
18.1 Definitions:
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
(a) Validation: The documented act of providing that any procedure, process, equipment,
material, activity or system actually leads to the expected results.
(b) Process Qualification: “Providing documented evidence that the process does what it
purports to do”.
(d) Challenge Test: “A condition or set of conditions encompassing upper & lower
processing limits and circumstances, within Standard Operating Procedure, that poses
the greatest chance of product or process failure when compared to ideal conditions”.
Such conditions do not necessarily induce product or process failure.
(e) Cleaning Validation: A process giving evidence that the cleaning operation can
consistently meet predetermined standards.
(g) Specificity: The ability to unequivocally assess the analyte in the presence of
components, which may be expected to be present.
Psychotropics India Limited
Plot No. – 46 & 49, Sector -6A, IIE, SIDCUL, Haridwar (U.K.)
19.0 Abbreviations:
ADI Acceptable Daily Intake
CIP Clean- In -Place
COP Clean- Out- Of-Place
DQ Design Qualification
IQ Installation Qualification
MAR Maximum Allowable Residue
OQ Operational Qualification
PPM Parts Per Million
PQ Performance Qualification
QA Quality Assurance
QC Quality Control
SOP Standard operating Procedure
TOC Total organic Carbon
RSD Relative Standard Deviation
NMT Not more than
NLT Not less than
LOD Limit of Detection
LOQ Limit of Quantitation
Mcg Microgram
ppm Parts per million