Masoneilan, Mooney, Becker
Released: March 8th, 2019
ValSpeQ v4.11.1 Full Edition
For Additional Information Contact:
German Rivera, Digital Technology Senior Alfredo Castravelli, Sizing & Configuration Tool
Leader – Configuration Products Leader
Office: +1 508 941 5427 Office: +39 81 789 2263|
Email: [email protected] Email: [email protected]
How to Download and Install
Go on https://www.gefptconnect.com and sign with your SSO credentials
Scroll down page up to Online Tools / ValSpeQ (is second last link) and
download zip file .
Uninstall previous versions trough Control Panel
Extract the file on your desktop, don’t run it directly from the zip.
Run the ValSpeQ4.11.exe program with right click, “Run as Administrator”
option.
Release scope
Major fixes as reported by users in 4.11
Configured Items are converted to “Preliminary Calculation “under certain scenarios.
Open / Close Torque values are not shown for 35000 & 36000
SAP xml generates error when exported
Minimum Temperature for Painting did not include the low temperature cases
Paint System was not properly translated
ITP returns error when trying to save the acceptance criteria
Auto Actuator Sizing for Camflex fails if Supply Pressure was limited under certain values
(enhancement)
Addition of EN material for 21000 and 41005 (enhancement)
Dimensional Data stored in vnx (enhancement)
Fixed error when move off a line that requires calculation
Fixed Dimensions for Displacer 12403
Review of Lead Time (21000 and 36000)
Known Issues with this Build
AI returns CF on Bonnet Bellow charge
Check for Windows 7-8
Right click the shortcuts on your desktop and select properties, then navigate to the
compatibility tab.
Check “Run this program in compatibility mode for “Windows XP (Service Pack 3)”
Check “Run this program as an administrator
Development in this release
Product Line Description
Vector Obsolescence
Accessories Remove Vector replacing with new P & F
Accessories Remove Vector replacing with new P & F
Accessories Remove Vector replacing with new P & F
Accessories Bug when selected certification
33000 Revision
33000 Add the new mounting positions vs. Flow Direction as per CES 485 rev E (Data)
33000 Change the C7 Fcator to 1
New Painting Spec
General Update PAINT_SYSTEM_LNG Data
General Update PAINT_SYSTEM_M Data
General Remove aluminum switch paint (make it default change paint by tempertuare)
General Remove Actuator Case Paint
General Update Reference Temperature
General Handwheel for 51-52-53 to be set not Paint
General Handwheel for 51-52-53 to be set not Paint
General Remove Actuator Case Paint , Explicit actuator paint system and update new
parameters , Valve, Level and DSH
Becker Development Phase III
Becker Becker Pricing Structure (with no records, only structure)
Becker Becker Pricing Structure (with no records, only structure)
Becker Pilot fields cannot be overridden.
Becker Enable Masoneilan ITP for Becker Valves
Becker Accessories Sheet is not created if pneumatic accessories are selected without
pilot:
Becker Signal Seelctor error
Mooney Development Phase III
Mooney Set regional Factor to 0.6
Mooney Fix 900 TE Tube Price
Mooney Add Second Pilot on UpStream Valve
Mooney Add Second Pilot on UpStream Valve
Mooney Add Second Pilot on UpStream Valve
Mooney Add Second Pilot on UpStream Valve
Mooney Mounting to "-" Mooney FlowMax regulators with bronze Series 20L pilots
Mooney Mounting to "-" Slam Shut regulators with bronze Series 20L pilots
Mooney Add mounting "-" to all mounting types as option.
Mooney Mounting to "-" Flowgrid Slam Shut regulators with bronze-body pilots
Mooney Set 4” and 6” Class 600 Flowgrid regulators with a bronze-body Series 20L pilot
as "-". All otehr combinations, even with Bronze Pilot, has all mountings
Mooney Replace A 193 Gr B5 for 900 TE in to SAE J429 Gr. 5
Mooney Add dropdown for preferred end connection type (autoselect can use that) ,
manual select can pick any
Mooney Rating error for Mooney valves
Mooney Change charges to pilot and set mounting charges to zero .
NPI: 41005 & High Capacity phase 5
41000 Add new size for 14" as sizing data and configurations
41000 Add new trims for 14" as sizing data and configurations
41000 Add new trims for 14" as model code
41000 Add new trims for14" as Price
41000 Add new trims for 14" as Lead Time
41000 Add new wieght and dimensions 14"
41000 Cage Material for 700 Plug (HT Metal Seal Ring) to be set to Nitrited , Chrome
Plated Cage not allowed
41000 Add Flow to Close to Two phase Fluid, as per email to Groves
41000 Lo dB High Capacity does not have l/d ration causing high noise
NPI: 35000 Construction Rules Addition
35000 Review Plug , Seat and Retainer Combinations as per CES 224 rev N (pending
Alfredo check with Conde) . Alfredo to send just the missing combination
35000 Add Splurry Construction as per CES 224 rev N
TRS
Description
General Add of GOST UZ (Uzbekistan) certifications for SVI II AP, SVI II ESD, SVI FF and
SVi1000.
General Add of GOST AZ (Azerbaijan) certifications for SVI II AP, SVI II ESD, SVI FF,
SVi1000 and 496.
General Add of GOST AZ (Azerbaijan) certifications for 496.
General Add of TAIWAN TS certifications for SVi1000, SVI II AP, SVI II ESD, SVI FF and
12400.
General Svi1000: updates on IECEx marking.
General 4700-4800: update son CUTR and INMETRO. Add of Dust marking for IA (South
Africa).
General 8012-8013: add of Dust marking for IA (South Africa). Updates on ATEX
markings. Update to IP65 rating.
General SVI II AP and SVI II ESD: minor updates on ATEX, FM, IECEx, CCOE and IA. Add of
dust approvals on INMETRO and NEPSI.
General 4411: add of Dust marking for IA (South Africa).
General 12400: minor updates on CU TR and IA. Add of Dust approvals on NEPSI.
Deletion of Ex ic approvals INMETRO.
Bugs & maintenance
General Item get invalid if you naviagte in to price node
General Item get invalid if you change TAG or Item number
35002 Camflex actuator sizing returning errors
84003 Intermediate Class label is not linked to selection on UI
General Specification Sheet does not show NACE grade
84003 Runtime error while customizing Steamform model number
49000 Positioner is not printed
Becker Positioner air set has no data
Becker Gap Action has no data
535H Fix H1 dimension in mm
General Flashing does not indicates [I] velocity
12400 custom a Vent Connection, save and be back, for some reason the “Flange
Finish” appears to be customized too
DSH The Standalone DSH cannot be exported
21000 review Plug Weight Data
41005 review Plug Weight Data
84003 review Plug Weight Data
General Correct Stroke Speed report actions
General V Report get error when try to print not valid item
General V report must prevent print of non valid item
21000 Actuatro Sizing Returns error with Cv = 6
84000 Customized Tubing are not being saved
General Check Positiner Air Set Max Supply Pressure vs Availabel Supply (if given ) and
Positioner AirSet Min / Max Set Pressure against Required Supply Pressure .
18000 Warning Lift set to 15% message, change reflected in CES 2102, Lincolnlog only
12000 12828 range 60” reports a Face to Face =66” while must be 68”
General For positioner stand alone, if model is overriden, the field is not saved
General For positioner stand alone, if mounting kit is overriden, the field is not saved
80000 Conversion for 80000 Fail Action Port
General Conversion for 35000 Fail position in Air to Close
84003 Runtime error while calculating by Outlet Flow Rate
Enhancements
General Show the Force to Open and the Force to Close separately in UI
21000 The "C " quote (half body to o bonnet) for 6” 21k Bellows seal reports 756 mm
vs 1114 mm (correct as per CES 317)
General Sizing, Selection Notes, Item and TAG shoudl not force the recalculation
General Force flashing as fluid state if p2 is less than pv
Price and Lead Time Update
General DVI Lead Times
535H Update 500 Series missing records
General 2019 price change
General 2019 price change
Conversion
General Convert positioner approval