0% found this document useful (0 votes)
186 views6 pages

Siemens RAB21 (3 Hızlı Daikin Heating Ve Veya Cooling Yapabilir)

The document provides information on the RAB21 and RAB21.1 room thermostats. It describes their functions for heating, cooling, fan control, ventilation, and changeover. It also includes information on mounting, installation, commissioning, maintenance, ordering, and technical data. The thermostats are used in heating and cooling systems to maintain the selected room temperature in commercial, residential, and light industrial buildings.

Uploaded by

Bora Ünsal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
186 views6 pages

Siemens RAB21 (3 Hızlı Daikin Heating Ve Veya Cooling Yapabilir)

The document provides information on the RAB21 and RAB21.1 room thermostats. It describes their functions for heating, cooling, fan control, ventilation, and changeover. It also includes information on mounting, installation, commissioning, maintenance, ordering, and technical data. The thermostats are used in heating and cooling systems to maintain the selected room temperature in commercial, residential, and light industrial buildings.

Uploaded by

Bora Ünsal
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 6

3 016

RAB21 RAB21.1

Room Thermostats RAB21..


For two-pipe fan coils

• Room thermostat for heating or cooling


• Changeover function (with external automatic aquastat)
• Two-postition control
• Manual three-speed fan switch
• Switching voltage AC 24…250 V
• Control output ON/OFF

Use

The RAB21.. room thermostat is used in heating or cooling systems to maintain the
selected room temperature.
Typical use:
• Commercial buildings
• Residential buildings
• Light industrial buildings
In conjunction with
− zone valves and thermal valves
− fans
− aquastats

CE1N3016en
2016-03-25 Building Technologies
Functions

Heating If the room temperature falls below the selected setpoint, the heating contact will close.
Cooling If the room temperature exeeds the selected setpoint, the cooling contact will be
closed.
Fan speed There are two possibilities to control the fan speed:
a) Manually by means of the three-speed fan switch on the thermostat for continuous
operation
b) Antomatically by switching to the select fan speed via the thermostat for controlled
operation. In that case – prior to commissioning – the jumper positions correspond-
ing to the functions must be selected. There are three choices of jumper positions
available on printed circuit board:
SR1 Select fan speed as continuous operation
SR2 Auto Fan is switched with the cooling valve
SR3 Auto Fan is switched with the heating valve
Ventilation When the ventilation function is selected (RAB21.1 only) on the front cover of the
slide switch, the heating and cooling contacts are always open and the fan operates at
the selected speed.

Changeover If required, heating or cooling can be selected externally (aquastat).


Function diagrams Heating Cooling

T Room temperature T Room temperature


SD Switching differential SD Switching differential
W Room temperature setpoint W Room temperature setpoint
Y1 Valve output signal " Heating " Y2 Valve output signal " Cooling "

Type summary

Two-pipe fan coil room thermostat for use with 3-speed fan, external RAB21
(automatic) changeover

Two-pipe fan coil room thermostat for use with 3-speed fan, external RAB21.1
(automatic) changeover and ventilation function

Equipment combinations

Type of unit Type reference Data sheet*)


Motoric on/off actuator SFA21.. 4863
Thermal actuator (for radiator valve) STA21.. 4893
Thermal actuator (for small valve 2.5 mm) STP21.. 4878
Electromotoric actuator for zone valve VVI46.. SUA21.. 4830
(2 position on/off)
*)
The documents can be downloaded from http://siemens.com/bt/download.

2/6

Siemens Room Thermostats RAB21.. CE1N3016en


Building Technologies 2016-04-13
Accessories

Description Type refernce


Adapter plate 120 x 120 mm for 4“ x 4“ conduit boxes ARG70
Adapter plate 96 x 120 mm for 2“ x 4“ conduit boxes ARG70.1
Adapter plate for surface wiring 112x130 mm ARG70.2

Technical design

Key features of the RAB21.. fan coil room thermostat:


• Two-position control
• Gas-filled diaphragm

Adjustments

The required temperature can be selected by a setpoint adjuster on the front of thermo-
stat.
The setpoint setting range can be mechanically limited by means of setpoint limiter
under the cover.

Notes

Mounting, installation The thermostat should be located where the air temperature can be sensed as accu-
and commissioning rately as possible, without getting adversely affected by direct solar radiation or other
heat or refrigeration sources.
Mounting height is about 1.5 m above the floor.

The unit can be fitted to most commercially available recessed conduit boxes or directly
on the wall.
Only authorised personnel may open the unit to perform service.
Warning: AC 250 V!
The unit must be isolated from the mains supply before opening.

When installing the unit, fix the base plate, first then hook on the thermostat body and
make the electrical connections. Then fit the cover and secure it (also refer to separate
mounting instructions).
The thermostat must be mounted on a flat wall.
The local electrical regulations must be complied with.
If there are thermostatic radiator valves in the reference room, set them to their fully
open position.
Warning!
No internal line protection for supply lines to external consumers
(Q1, Q2, Q3, Y1, Y2)
Risk of fire and injury due to short-circuits!
• Adapt the line diameters as per local regulations to the rated value of the installed
overcurrent protection device.

3/6

Siemens Room Thermostats RAB21.. CE1N3016en


Building Technologies 2016-04-13
Maintenance The room thermostat is maintenance-free.
Mechanical design The diaphragm is filled with environmentally friendly gas.
The thermostat housing is made of plastic.

Ordering

Type (ASN) Part number (SSN) Description


RAB21 S55770-T227 Room thermostat RAB21
RAB21.1 S55770-T228 Room thermostat RAB21.1

Disposal

The devices are considered electronics devices for disposal in term of European
Directive 2012/19/EU and may not be disposed of as domestic waste.
• Dispose of the device via the channels provided for this purpose
• Comply with all local and currently applicable laws and regulations.

Technical data

Switching capacity
Power supply Voltage AC 24…250 V
Current 0.2…6 (2) A
Frequency 50 or 60 Hz
No internal fuse
External preliminary protection with max. C 10 A circuit breaker in the supply line required under all
circumstances
Screw terminals for 2 x 1.5 mm2 (min. 0.5 mm2)
Operational data Switching differential SD ≤1 K
Setpoint setting range 8…30 °C
Environmental conditions Operation to IEC 60721-3-3
Climatic conditions Class 3K5
Temperature 0…50 °C
Humidity <95 % r.h.
Pollution degree normal, to EN 60730-1
Transport / storage to IEC 60721-3-2
Climatic conditions Class 2K3/1K3
Temperature -20…50 °C
Humidity <95 % r.h.
Mechanical conditions Class 2M2
Industry standards EU Conformity (CE) CE1T3015xx *)
RCM Conformity CE1T3561en_C1 *)
Safety standard II to EN 60730-1
Degree of protection of housing IP30 to EN 60529
Environmental The product environmental declaration CE1E3015*) contains data on environmentally
compatible product design and assessments (RoHS compliance, materials composition,
compatibility packaging, environmental benefit, disposal).
Mechanical design Weight 0.14 kg
Colour white, NCS S 0502-G (RAL 9003)
*)
The documents can be downloaded from http://siemens.com/bt/download.

4/6

Siemens Room Thermostats RAB21.. CE1N3016en


Building Technologies 2016-04-13
Connection diagrams

Heating or cooling Changeover for heating or cooling


(with external automatic aquastat)

3016A01

3016A02
D1 Zone valve or thermal valve for D1 Zone valve or thermal valve for
heating or cooling heating or cooling via Aquastat
L Switching voltage AC 24…250 V L Switching voltage AC 24…250 V
N Neutral N Neutral
M1 3-speed fan M1 3-speed fan
N1 Room thermostat N1 Room thermostat
Q1 Control output "Fan speed I", AC 24…250 V Q1 Control output "Fan speed I",
Q2 Control output "Fan speed II", AC 24…250 V AC 24…250 V
Q3 Control output "Fan speed III", Q2 Control output "Fan speed II",
AC 24…250 V AC 24…250 V
Y1 Control output "Valve actuator heating", Q3 Control output "Fan speed III",
AC 24…250 V AC 24…250 V
Y2 Control output "Valve actuator cooling", Y1 Control output "Valve actuator heating",
AC 24…250 V AC 24…250 V
Y2 Control output "Valve actuator cooling",
AC 24…250 V
S1 Aquastat e.g. RYT182

Dimensions

Room thermostat Base plate

5/6

Siemens Room Thermostats RAB21.. CE1N3016en


Building Technologies 2016-04-13
Remarks

Heating:
Because of the unavoidable self heating effects of the electrical current, any loads of
more than 3 Amperes connected to the unit can influence the control behavior and
temperature accuracy in a negative way.

Cooling:
Because of the unavoidable self heating effects of the electrical current, any loads of
more than 1 Amperes connected to the unit can influence the control behavior and
temperature accuracy in a negative way.

6/6  Siemens Switzerland Ltd, 2011 - 2016 Subject to change