This document provides test reports for oil filtration of transformers for two customers - M/s Indian Oil Corporation Ltd and M/s Akshaya Electricals. It details the specifications of two transformers that underwent testing, including make, rating, voltage. It reports the breakdown voltage and acidity test values before and after oil filtration, indicating the oil quality was satisfactory after filtration for both transformers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
281 views3 pages

IOC Tr. Oil Test Report

This document provides test reports for oil filtration of transformers for two customers - M/s Indian Oil Corporation Ltd and M/s Akshaya Electricals. It details the specifications of two transformers that underwent testing, including make, rating, voltage. It reports the breakdown voltage and acidity test values before and after oil filtration, indicating the oil quality was satisfactory after filtration for both transformers.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 3

TIN 33251085384 DURGA SWITCHGEARS

A-Grade Contractors EA 2616


CST 872774/08-01-08 (Servicing, Repairing Testing of all kinds of LT/HT Circuit Breakers,
AREA CODE 0 5 5 Protective relays, Transformer oil filtration and High pot Test)
Branch: PAGE 1a
9, ANBIL NAGAR,
AIRPORT ROAD, Mobile: 9884320732 Office; 044 – 25550453
TIRUCHIRAPPALLI – 620 007. Mail : [email protected]

HO: 8/5, JOHN VASU STREET, MADHAVARAM MILK COLONY, CHENNAI – 600 051
DATE OF OIL FILTRATION : 21ST MAY 2012
TRANSFORMER OIL TEST REPORT
THE CHIEF TERMINAL MANAGER,
NAME OF THE CONSUMER :
M/S INDIAN OIL CORPORATION LTD.,
KORUKKUPET,
TRANSFORMER SPECIFICATION:-
CHENNAI- 600 021
 
 

LOCATION : OUTDOOR
Make : ALSTHOM
Rating : 100 KVA
Voltage HV / LV : 433 / 415Volts
Maker’s Serial No. : 7688C

Next Oil Filtration Due on : 21ST MAY 2013

TEST KIT DETAILS:-


Make : VA Power India

Serial Number : S 200315


Kit Calibration Due Date : 23-08-2012
Input : 230 V. AC, Output : 0 – 60KV, Freq.: 50HZ Single Phase

TESTED BDV VALUES:- TEST GAP BETWEEN ELECTRODES : 2.5mm

OIL SAMPLES -- BREAK DOWN VOLTAGE VALUES IN KV AC.


NO. OF As per Speciation
Before Filtration After Filtration Test Result
TEST Value
1 31 50
2 30 50
3 29 50
4 40KV SATISFACTORY
31 50
5 30 50
6 30 50
TOTAL 181 250
AVERAGE 30.1 KV 50 KV

BOTTOM Sample withstood 40KV for One minute

ACIDITY TEST:- 0.15 MILLIGRAM OF KOH / GRAM OF OIL


Maximum permissible value : 0.30 mg of KOH
FOR DURGA SWITCHGEARS

(AUTHORISED SIGNATORY)
TIN 33251085384 DURGA SWITCHGEARS
A-Grade Contractors EA 2616
CST 872774/08-01-08 (Servicing, Repairing Testing of all kinds of LT/HT Circuit Breakers,
AREA CODE 0 5 5 Protective relays, Transformer oil filtration and High pot Test)
Branch: PAGE 1b
9, ANBIL NAGAR,
AIRPORT ROAD, Mobile: 9884320732 Office; 044 – 25550453
TIRUCHIRAPPALLI – 620 007. Mail : [email protected]

HO: 8/5, JOHN VASU STREET, MADHAVARAM MILK COLONY, CHENNAI – 600 051
DATE OF OIL FILTRATION : 21ST MAY 2012
TRANSFORMER OIL TEST REPORT
THE CHIEF TERMINAL MANAGER,
NAME OF THE CONSUMER :
M/S INDIAN OIL CORPORATION LTD.,
KORUKKUPET,
TRANSFORMER SPECIFICATION:-
CHENNAI- 600 021
 
 

LOCATION : INDOOR
Make : INDO TECH
Rating : 500 KVA
Voltage HV / LV : 11000 / 433 Volts
Maker’s Serial No. : IT 16654

Next Oil Filtration Due on : 21ST MAY 2013

TEST KIT DETAILS:-


Make : VA Power India

Serial Number : S 200315


Kit Calibration Due Date : 23-08-2012
Input : 230 V. AC, Output : 0 – 60KV, Freq.: 50HZ Single Phase

TESTED BDV VALUES:- TEST GAP BETWEEN ELECTRODES : 2.5mm

OIL SAMPLES -- BREAK DOWN VOLTAGE VALUES IN KV AC.


NO. OF As per Speciation
Before Filtration After Filtration Test Result
TEST Value
1 33 50
2 32 50
3 33 50
4 40KV SATISFACTORY
30 50
5 31 50
6 31 50
TOTAL 190 250
AVERAGE 31.6 KV 50 KV

TOP & BOTTOM Samples ---- withstood 40KV for One minute

ACIDITY TEST:- 0.17 MILLIGRAM OF KOH / GRAM OF OIL


Maximum permissible value : 0.30 mg of KOH
FOR DURGA SWITCHGEARS

(AUTHORISED SIGNATORY)
TEST REPORT

FOR

TRANSFORMER OIL FILTRATION

M/S INDIAN OIL CORPORATION LTD.,

KORUKKUPET,

CHENNAI – 600 021.

Carried out

On

21ST May 2012

FOR
M/S AKSHAYA ELECTRICALS, PERAMBUR. CHENNAI.

JOB CARRIED OUT BY : DURGA SWITCHGEARS


A-GRADE CONTRACTORS EA 2616
No. 8/5, John Vasu Street,
Madhavaram Milk Colony,
Chennai – 600 051.