DN027B Led20nw D200 RD

1. The document provides specifications for a General Uniform Lighting fixture model DN027B LED20/NW D200 RD APT3014, including light output of 1900 lumens, intensity diagrams, and recommendations for quantity and spacing to achieve lighting levels of 750, 500, and 300 lux. 2. Tables include utilization factors for various reflectance levels to estimate lighting levels and luminance values at angles from the horizontal plane. 3. The fixture is intended for ceiling mounting and complies with EN12464-1 standards for uniform lighting distribution.

Uploaded by

Haianh Pham
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
70 views1 page

DN027B Led20nw D200 RD

1. The document provides specifications for a General Uniform Lighting fixture model DN027B LED20/NW D200 RD APT3014, including light output of 1900 lumens, intensity diagrams, and recommendations for quantity and spacing to achieve lighting levels of 750, 500, and 300 lux. 2. Tables include utilization factors for various reflectance levels to estimate lighting levels and luminance values at angles from the horizontal plane. 3. The fixture is intended for ceiling mounting and complies with EN12464-1 standards for uniform lighting distribution.

Uploaded by

Haianh Pham
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

General Uniform Lighting

DN027B LED20/NW D200 RD APT3014

1 x 1900 lm

Polar
o
Intensity
o
Diagram o Quantity estimation diagram
120 180 120 nr. of luminaires
hroom : 2.8 m
Reflectances: 0.70, 0.50, 0.20
o o
90 90 40 Maintenance factor: 1.0
Ceiling mounted
750 lx
o 100 o 30
60 60
500 lx
200 20
300 lx
300
10
o o
30 400 30
0
o 2
(cd/1000lm) 0 L.O.R.=1.00 10 30 50 70 90 (m )
o o
0-180 90-270
Utilisation factor table Luminance Table
Light output ratio 1.00
Service upward 0.00 Reflectances (%) for ceiling, walls and working plane (CIE) Plane 0.0 45.0 90.0
Room Cone
Service downward 1.00 0.80 0.80 0.70 0.70 0.70 0.70 0.50 0.50 0.30 0.30 0.00
45.0 1763 1769 1760
Index 0.50 0.50 0.50 0.50 0.50 0.30 0.30 0.10 0.30 0.10 0.00
50.0 1747 1754 1745
CIE flux code 47 79 96 100 100 k 0.30 0.10 0.30 0.20 0.10 0.10 0.10 0.10 0.10 0.10 0.00
55.0 1715 1724 1712
60.0 1673 1682 1669
0.60 0.48 0.46 0.47 0.46 0.45 0.38 0.37 0.32 0.37 0.32 0.30
65.0 1613 1625 1606
EN12464-1 55 deg, 2000 cd/m2 0.80 0.59 0.55 0.58 0.56 0.55 0.47 0.46 0.41 0.46 0.41 0.39
1.00 0.68 0.63 0.66 0.64 0.62 0.55 0.54 0.49 0.53 0.49 0.46 70.0 1533 1548 1526
1.25 0.77 0.70 0.75 0.72 0.69 0.62 0.61 0.56 0.60 0.56 0.54 75.0 1408 1430 1433
1.50 0.83 0.75 0.81 0.78 0.74 0.68 0.67 0.62 0.66 0.62 0.59 80.0 1276 1301 1265
2.00 0.93 0.83 0.91 0.86 0.82 0.77 0.75 0.71 0.74 0.71 0.68
85.0 1060 1089 1045
2.50 1.00 0.88 0.97 0.92 0.87 0.82 0.81 0.77 0.80 0.76 0.74
3.00 1.05 0.92 1.02 0.96 0.90 0.86 0.85 0.82 0.83 0.81 0.78 90.0 - - -
4.00 1.11 0.96 1.07 1.01 0.95 0.91 0.90 0.87 0.88 0.86 0.83 (cd/m2)
5.00 1.14 0.98 1.11 1.04 0.97 0.94 0.93 0.90 0.91 0.89 0.86

Ceiling mounted