Maintenance Schedule
ACS880-107, -207, -307, -607, -907, -1607 multidrive ABB Oy, Drives Service
Valid for drives manufactured or maintained in 2017 onwards.
Recommended maintenance intervals and component replacements are based on specified operational and environmental conditions. ABB
recommends annual drive inspections to ensure the highest reliability and optimum performance. More detailed maintenance information can
be found in maintenance instructions, product manuals and on the Internet.
www.abb.com/drives
NOTE! Long term operation near the maximum specified ratings or environmental conditions may require shorter maintenance
intervals for certain components. Check the device specific technical specifications in the relevant hardware manual and consult
your local ABB Service for maintenance recommendations at:
www.abb.com/searchchannels
Legend
I Inspection (visual inspection and maintenance action if needed)
P Performance of on/off-site work (commissioning, tests, measurements or other work)
R Replacement
Functional safety actions
Safety function test interval I
Safety component expiry (Mission time TM) 20 years R
Recommended annual actions by the user
Connections and environment
Cabinet door filters IP54 R
Quality of supply voltage P
Spare parts
Spare parts I
DC circuit capacitors reforming, spare modules and spare capacitors P
Inspections by user
IP22 and IP42 air inlet and outlet meshes I
Tightness of terminals I
Dustiness, corrosion and temperature I
Heat sink cleaning I
Other
ABB-SACE Air circuit breaker maintenance I
Years from start-up
Cooling
3 6 9 12 15 18 21
Main cooling fan
R1i to R4i speed controlled LONG-LIFE R R
R5i to R7i speed controlled LONG-LIFE R R
D6D to D7D/D7T direct on line 50Hz LONG-LIFE R R
D6D to D7D/D7T direct on line 60Hz LONG-LIFE R R
D8D (50/60Hz) * R R
R8i and D8T direct online 50Hz LONG-LIFE R R
R8i and D8T direct online 60Hz LONG-LIFE R R
LCL, L and BDCL direct online 50Hz LONG-LIFE R R
LCL, L and BDCL direct online 60Hz LONG-LIFE
1) R1) R R1) R / R1)
6 years interval if fan supply voltage is 400V instead of 320V
D7T speed controlled * R R
R8i and D8T speed controlled * R R
Internal cooling fan for circuit boards
R5i LONG-LIFE R R
R8i and D8T * R R
Cabinet cooling fan
Internal LONG-LIFE 50Hz R R
Internal LONG-LIFE 60Hz R R R
Door LONG-LIFE 50 Hz R R
Door LONG-LIFE 60Hz R R
IP54 50Hz* R R
IP54 60Hz * R R R
NSIN filter cooling fan
Filter cooling fan direct online 50Hz* R R
Filter cooling fan direct online 60Hz* R R
* Fan has been always "LONG-LIFE" type
Document No.: 4FPS10000292961
Date: 08.11.2019
© Copyright 2019 ABB Oy. All rights reserved Revision: I
Maintenance Schedule
ACS880-107, -207, -307, -607, -907, -1607 multidrive ABB Oy, Drives Service
Valid for drives manufactured or maintained in 2017 onwards.
Years from start-up
Aging
3 6 9 12 15 18 21
Common, control panel and control unit batteries
ZCU/BCU control unit battery (Real-time clock) R R R
Control panel battery (Real-time clock) R R
INU R1i…R4i
JPU power unit (R1i and R2i) R R
JCAP capacitor board (R3i and R4i) R R
ZCU control unit R
INU R5i
ZCU control unit R
INU, ISU R6i, R7i
DC circuit electrolytic capacitors+discharg. resistors R R
ZPOW
R
module internal power supply board
ZINT
R
module internal circuit board
ZCU control unit R
INU, ISU, DBU, RRU, DDC R8i
DC circuit electrolytic capacitors+discharg. resistors R R
BDPS,BFPS
R
module internal power supply boards
BINT, BGDR, BDFC
R
module internal circuit boards
Flat ribbon cables (when boards replaced) R
BCU control unit R
BSFC
R
Cabinet side charging control board (INU only)
DSU D7T, D8T
BDPS, BFPS
R
module internal power supply boards
BINT, BTDR, BPCB, BDFC
R
module internal circuit boards
Flat ribbon cables (when boards replaced) R
BCU control unit R
Filter unit capacitors
BLCL capacitor R R
NSIN capacitor R R
Document No.: 4FPS10000292961
Date: 08.11.2019
© Copyright 2019 ABB Oy. All rights reserved Revision: I
Maintenance Schedule
ACS880-107, -207, -307, -607, -907, -1607 multidrive ABB Oy, Drives Service
Valid for drives manufactured 2016 or before.
Recommended maintenance intervals and component replacements are based on specified operational and environmental conditions. ABB
recommends annual drive inspections to ensure the highest reliability and optimum performance. More detailed maintenance information can
be found in maintenance instructions, product manuals and on the Internet.
www.abb.com/drives
NOTE! Long term operation near the maximum specified ratings or environmental conditions may require shorter maintenance
intervals for certain components. Check the device specific technical specifications in the relevant hardware manual and consult
your local ABB Service for maintenance recommendations at:
www.abb.com/searchchannels
Legend
I Inspection (visual inspection and maintenance action if needed)
P Performance of on/off-site work (commissioning, tests, measurements or other work)
R Replacement
Functional safety actions
Safety function test interval I
Safety component expiry (Mission time TM) 20 years R
Recommended annual actions by the user
Connections and environment
Cabinet door filters IP54 R
Quality of supply voltage P
Spare parts
Spare parts I
DC circuit capacitors reforming, spare modules and spare capacitors P
Inspections by user
IP22 and IP42 air inlet and outlet meshes I
Tightness of terminals I
Dustiness, corrosion and temperature I
Heat sink cleaning I
Other
ABB-SACE Air circuit breaker maintenance I
Years from start-up
Cooling
3 6 9 12 15 18 21
Main cooling fan
R1i to R4i speed controlled R R R
R5i to R7i speed controlled R R R
D6D to D7D/D7T direct on line 50Hz R R R
D6D to D7D/D7T direct on line 60Hz R R R
D8D (50/60Hz) R R
R8i and D8T direct online 50Hz R R R
R8i and D8T direct online 60Hz R R R
LCL, L and BDCL direct online 50Hz R R R
LCL, L and BDCL direct online 60Hz LONG-LIFE
1) R1) R R1) R / R1)
6 years interval if fan supply voltage is 400V instead of 320V
D7T speed controlled R R
R8i and D8T speed controlled R R
Internal cooling fan for circuit boards
R5i R R R R R R R
R8i and D8T R R
Cabinet cooling fan
Internal 50Hz R R R
Internal 60Hz R R R R R R R
Door 50Hz R R R
Door 60Hz R R R
IP54 50Hz R R
IP54 60Hz R R R
NSIN filter cooling fan
Filter cooling fan direct online 50Hz R R
Filter cooling fan direct online 60Hz R R
Document No.: 4FPS10000292961
Date: 08.11.2019
© Copyright 2019 ABB Oy. All rights reserved Revision: I
Maintenance Schedule
ACS880-107, -207, -307, -607, -907, -1607 multidrive ABB Oy, Drives Service
Valid for drives manufactured 2016 or before.
Years from start-up
Aging
3 6 9 12 15 18 21
Common, control panel and control unit batteries
ZCU/BCU control unit battery (Real-time clock) R R R
Control panel battery (Real-time clock) R R
INU R1i…R4i
JPU power unit (R1i and R2i) R R
JCAP capacitor board (R3i and R4i) R R
ZCU control unit R
INU R5i
ZCU control unit R
INU, ISU R6i, R7i
DC circuit electrolytic capacitors+discharg. resistors R R
ZPOW
R
module internal power supply board
ZINT
R
module internal circuit board
ZCU control unit R
INU, ISU, DBU, RRU, DDC R8i
DC circuit electrolytic capacitors+discharg. resistors R R
BDPS,BFPS
R
module internal power supply boards
BINT, BGDR, BDFC
R
module internal circuit boards
Flat ribbon cables (when boards replaced) R
BCU control unit R
BSFC
R
Cabinet side charging control board (INU only)
DSU D7T, D8T
BDPS, BFPS
R
module internal power supply boards
BINT, BTDR, BPCB, BDFC
R
module internal circuit boards
Flat ribbon cables (when boards replaced) R
BCU control unit R
Filter unit capacitors
BLCL capacitor R R
NSIN capacitor R R
Document No.: 4FPS10000292961
Date: 08.11.2019
© Copyright 2019 ABB Oy. All rights reserved Revision: I