DIAM4000

Single-phase Constant Current Regulator

COMPLIANCE STANDARDS

ICAO Aerodrome design manual, part 5


IEC (61822)
CENELEC (ENV 50231)
STNA (91068 rev.93)
FAA (AC150/5345-10F – L828/L829)
AENA (PPT002 ed4-2004)

APPLICATIONS
DIAM4000 series CCRs are low-cost fully static devices controlled by two
thyristors. They are designed to maintain a constant, pre-displayed and
adjustable output current independently of load or power supply
fluctuations. These devices are specifically designed for airfield lighting on
runways, taxiways or aprons. They meet all international standards.
Electronics, using the latest digital technology, can be controlled and
monitored by the mean of the most popular serial networks with or without
redundancy, as well as the most simple universal multiwire interface.

ADVANTAGES
Flexibility of operation :
The large semigraphic alphanumeric display combined with a menu type
keyboard allows the CCR to be configured without connecting a computer.
Regulation is fully digital, which enables parameters to be simply adapted
in case of particular load or special application. Auto-calibration eliminates
the use of tedious setting, in case of long-time scheduled maintenance.
Emergency and warning messages are clearly displayed, as the current
state of the CCR or all input or output electrical measurements.
Maintenance optimisation :
These regulators show a very simplified architecture both for electronics,
LV part and HV power unit : It has been optimised to keep the number and
variety of spare parts to a minimum, in order to facilitate maintenance.
Software tools allow a fast fault diagnosis and test, without dismantling.
Purchase and life-cycle costs :
DIAM4000 series constant current regulators represents the best
compromise on the market between high performances, maintenance
services and the most reduced cost, thanks to an optimised design and a
NT 60 21052 DIAM4000 16-03-2009 latest state-of-the-art digital electronic technology.
DIAM4000 : Technical characteristics
GENERAL PRESENTATION
Each DIAM4000 is delivered into a metal frame with lifting rings. It includes 3 distinct parts:
an "electronic" compartment, a “Low voltage” compartment and a "high voltage" compartment

The Electronic part includes an electronic board whose design uses last digital
technologies; it is fixed at the front panel of the device. This front sheet supports the user
interface delivering any useful information, and allowing all local or distant operations.
Internal parts are accessible from the front or the top.

The Low voltage compartment includes all components involved in supplying and
controlling the device, as interface boards, fuses, terminals, thyristors. It is located at rear
in the upper part, and can be acceded dismantling the roof or the back panel.

The High voltage compartment is located at the lower part of the device, and
includes components connected to the lighting loop, as the power transformer, lightning
arrestors, load tapping and load terminals. It can be acceded opening the front panel of
the CCR. A door contact switch-off the CCR when opening the compartment, in order to
avoid contact hazard with high voltage electrical parts.

MECHANICAL FEATURES ELECTRICAL FEATURES


Protection : IP 21. (other on request) Supply: Single-phase 208 to 480 Vac ±10%
Dimensions (all powers and voltages): (IEC type) or –5/+10% (FAA type), 50/60 Hz ±5%
H 1380 mm, W 500 mm, D 700 mm Rated output current : 6.6 or 20 A
If ECB option (Loop Communication System type STB Max. Rated power : 30 kW
or SCB) : H 1580 mm, W 500 mm, D 700 mm Power factor : FAA type : > 90% (2.5 to
Inter-axes (If casters option): 355 x 610 mm 10kW CCRs) or > 95% (15 to 30kW CCRs).
Use : Normal temperature : -20°C to +55°C, IEC type : > 90% at nominal voltage and rated
humidity max. : 95%. (FAA style : -40°C to +55°C). resistive load
Natural air cooling. Efficiency : > 90% at rated parameters.

Accessibility: For opening the front and back Output current accuracy : Better than ±1%
panels. Distance min. between back and wall > 20 cm. under the following conditions : Power supply
voltage: ± 10% (IEC) or –5/+10% (FAA) -
Frequency: ± 5%, and Load: from 0 to 100%
PROTECTIONS Remote control : Voltage, from 20V to 60V
Lightning arrestors on outputs or input (option) DC, or dry contacts, or serial network.
Input circuit breaker instead of fuse (option) Back indication: Static dry contacts (IEC
type), or relay contacts (FAA), or serial network
Overcurrent, Open circuit, Under/Over voltage.
Black current : offered in standard (B0 :
preferred value 1.5 or 1.8 A)
USER INTERFACE
Made up of a flat polyester keypad on the front plate, it
includes a wide display of 16 x 140 p. With screen saver ,
showing preferably on the upper line (Blue) the installation
state, warnings and parameters, and on the lower line the
4 keys definition, depending of the present menu (Purple).
A 9-pins SubD socket located in front allows to connect a
lap-top PC to the CCR (for diagnostic or maintenance).
DIAM4000 : Display and Menus
DISPLAY FUNCTIONALITY CONFIGURATION MENU
The display shows 2 lines of text allowing to monitor The “Configuration” menu allows to set all basic
many parameters, values and warnings. The lower line parameters of the CCR to the processor (in case of
sets the definition of the keypad. The preferred mother board replacement, for example) :
information displayed can be changed in “STOP” mode,
Rated input voltage, from 208 to 480 Vac
and can be chosen (long press on STOP) among :
Rated power, in kVA, from 1 to 30 kVA
“Output current Io” – “brightness state Bx” Frequency, in Hz: 50 or 60
“Output current Io” – “Output power Po” Brightness number, from 1 to 8.
“Output current Io” – “Output voltage Uo” Type : FAA or IEC

DISPLAY EXAMPLES AND KEYS DEFINITION : OPTION MENU


The “Option” menu allows the following definitions:
“Stop” mode:
Parameter access: No
A change from No to Yes allows to change all parameters
of the DIAM4000, in order to avoid wrong operations.
“Local” mode : (B5 level). Press B+ or B- to Scrolling items, all optional features of the CCR
increase decrease the brightness : can be shown.

SETTING MENU
The “Setting” menu is used to assign all values of current
“Remote control” mode (B4 level): and/or delays to brightness levels, current range (min. &
max.), over current, open circuit fault detection, etc.
All these parameters are preferably set according the
current standard, but can be individually changed.

ALARMS AND WARNINGS LOAD ADAPTATION

All alarms (the CCR failed to supply the loop) and The output transformer is equipped
warnings (only indicative, without incidence on the loop) with an epoxy plate including
are clearly displayed. adjustment taps in order to adapt
the rated output voltage of the CCR
Example :”Open circuit” alarm : In order to to the load. Moving 2 brass straps
restart, first the fault shall be fixed and then the alarm allows to make steps of 12.5%.
cancelled, by pressing “reset” key.
CUT-OUT AND EARTHING PLATE
In option, the CCR can be equipped with an earthing cut-
out plate using 2 jumpers which allows to make all
Example : Earth Fault warning; in order to see maintenance and measurement operations on the loop,
what is the exact resistance value of the leakage without unscrewing any load or earth connections :
(from 0 to 10 Mohms), go in the “monitoring” menu.
Normal position : When the two
3 pins jumpers are in that position,
the CCR is supplying normally the
loop.
MONITORING
Parameters can be seen scrolling through the top-level
Safety position : When the two
menu items using the  and  keys :
3 pins jumpers are in that position,
the loop is short-circuited and
grounded, and the CCR is also
short-circuited and grounded.
Constant Current Regulator – DIAM4000
ORDERING INFORMATION
The DIAM regulator is identified by a serialised ordering number which indicates its type and particularity. If needed, add all
useful precision and options
Example : D40-IEC-1-5-50-15-400-B1-530 = DIAM4000 compliant to IEC, 6.6A, 5 brightness, 50Hz, 15kVA, 400Vac, with a
multiwire interface and Jbus serial network, with lightning arrestors on output terminals, Circuit breaker, EFD and LFD :
D 4 0 - I E C - 1 - 5 - 5 0 - 1 5 - 4 0 0 - B 1 - 5 3 0

Series D40: DIAM 4000 series

IEC: IEC type


Type 828: L-828 FAA Type (Options as described in L828 advisory are included)
829: L-829 FAA Type (Options as described in L829 advisory are included)
AXX : AENA compliance (A29 = AENA PPT2-1995; A04 = AENA PPT2/04/04-2004)

Class 1: Class1 (output current 6.6A)


2: Class2 (output current 20A)

3: Style 1 (Class1 : 4.8A, 5.5A, 6.6A)


Style 5: Style 2 (Class1 : 2.8A, 3.4A, 4.1A, 5.2A, 6.6A, or Class2 : 8.5A, 10.3A, 12.4A, 15.8A, 20A)
A: 5 brightness, AENA values
X: Number of brightness, up to 8 (not counting B0 = “black” current) : Values of currents must be specified separately

50: 50Hz Mains frequency


Freq.
60: 60Hz Mains frequency

Output 01: 1kVA 05: 5kVA 15: 15kVA 30: 30kVA


power 02: 2.5kVA 07: 7.5kVA 20: 20kVA
04: 4kVA 10: 10kVA 25: 25kVA

Supply XXX: 208, 220, 230, 240, 277, 380, 400, 415 or 480 Vac -5% +10% (FAA) or +/-10% (IEC) Mains Voltage

0X : No multiwire interface X0 : No communication network


AX : INTERNAL source Remote control X1 : 1 x JBus RS485 port
BX : EXTERNAL 20 to 60 Vdc Rem. control X2 : 2 x Jbus RS485 ports
Control CX : AENA terminal block X3 : 1 x Lonwork port
DX : Cylindrical sockets (SOURIAU) X4 : 1 x Ethernet port
GX : INTERNAL 120Vac remote control X5 : 1 x Jbus and 1 x Ethernet ports
HX : EXTERNAL 120Vac remote control X6 : 2 x Ethernet ports
(Only one letter must be selected) (Only one figure must be selected)

(If FAA type CCR, options as described in according advisory are included):

0XX : No extra protection options, X0X : No extra monitoring options, XX0 : No extra options
Regular 1XX : Lightning arrestors (outputs) X1X : Earth Fault Detector (EFD) XX1 : Cut-out / earthing jumpers
Options 2XX : Lightning arrestors (inputs) X2X : Lamp Failure Detector (LFD) XX2 : Casters (unidirectional)
4XX : Circuit Breaker X4X : Time meters (each brightness) XX4 : ECB included
(Final number : add all needed weights) (Final number : add all needed weights) (Final number : add all needed weights)

Other Options : Please specify (FAA cut-out plug, Protection rating other than IP21, Circuit selector, etc.)

AUGIER ® SA
BP 131 – 06513 CARROS Cedex
France
Tél +33 (0)4 92 08 62 00 – Fax +33 (0)4 93 29 01 40
[email protected]
www.augier.com

NT 60 21052 – DIAM4000 16-03-2009