Manual
Manual
UV-VIS Spectrophotometer
UV-1900i
Navigate Your Way
UV-i Selection
™
UV-1900i UV-2600i/2700i UV-3600i Plus SolidSpec -3700 i
™
Easy to Operate,
Ergonomic Obtain Answers Easily and Rapidly
Hardware Design
The control panel is ergonomically designed and positioned
at the optimum viewing angle for the user. Users can
operate easily with any posture. Since the panel is
pressure-sensitive, the device can be operated with gloved
fingers or a stylus pen. The stylus pen can be stored right
next to the control panel.
Easy-to-Use Interface
Grasp the Current Status and Operating Procedures at a Glance
The UV-1900i on-screen user interface includes large, easy-to-see icons deployed on a black background, so the instrument settings are evident at a
glance. In addition, the large, easy-to-see icons improve intuitive understanding, which enables users to quickly become familiar with the operations.
Furthermore, the user interface is designed to minimize transitions between windows, so users do not get confused
Display languages are available in eight languages (Japanese, English, during the
operations.
Chinese, Spanish, Portuguese, German, French, Russian).
4
High Performance to Meet Diverse Needs 3.00
Abs. Calibration Curve
Spectra can be acquired as fast as 29,000 nm/min. Ultra-fast scan is effective in tracking chemical reactions in a short time. In
1.50
addition to the absorbance change at specified wavelengths, spectra can also be acquired in a short time with the UV-1900i.
1.00
Therefore, more detailed behavior can be investigated by observing spectra with the UV-1900i.
0.50
The figures below show the analysis of the particle agglomeration process when salts are added to silver nanoparticles.
0.00
Measurements of the 300 to 700 nm region were performed in ultra-fast scan mode. In addition to the decrease of
0.00 1.00 2.00 3.00
absorbance at 400 nm and the increase of absorbance at 480 nm, the temporal changes of spectra can also be observed. Conc. (mg/L)
1.0 0.23
0.97
Black: after 0 min
Red: after 0.5 min 0.21
Blue: after 1 min 0.92 480nm
0.8
Green: after 2 min
0.19
Orange: after 5 min
0.77 0.15
0.4
0.13
0.72
400nm 0.11
0.2
0.67
0.09
The figure on the right is a calibration curve for caffeine, created with absorbance at 273 nm. The
calibration curve has an Abs = 0.0528 Conc. The lower limit of quantitation determined from the
standard deviation is 0.0051 mg/L.
UV-1900i
UV-VIS Spectrophotometer 5
2.5
2.0
No. Absorbance of Blank Solution (273
nm) 1.0
1 -0.00001
2 0.00001 0.5
3 -0.00002
4 0.00002
0.0
Note: One method of determining the lower limit of quantitation is to use ten 5 0.00001 0.0 10.0 20.0 30.0 40.0
times the standard deviation. 6 -0.00003
This is an actual measured value and is not guaranteed.Conc. (mg/mL) 7 0.00001
8 -0.00004
Various Functions for 9
10
0.00001
0.00005
Comfortable Daily
Standard 0.000025
Measurement Deviation σ
1 2
Data transfer function* PictBridge function*
*1: Optional expanded memory is required. The instrument is not compatible with control via a network.
*2: A PictBridge compatible printer is required.
Previous Next
day Start Time morning
Ready
9 : 00
6
*3: Use a bar-code reader and keyboard with a USB connection.
Measures the photometric value at a Measures a sample spectrum using Generates a calibration curve from the single wavelength or
multiple (up to wavelength scanning.measurement of standards, and then
eight) wavelengths. calculates the concentrations of
UV-1900i
UV-VIS Spectrophotometer 7
unknowns.
Foods
This is an example of the analysis of food dyes. By using ultra-fast scan
mode, the time needed for routine spectral checks can be shortened. The
350 nm to 900 nm region can be measured at 1 nm intervals in approx. 4
seconds.
8
This is an example of the analysis of λDNA. Trace quantities (on
1.00
0.80
Absorbance (Abs.)
0.60
0.40
0.20
0.00
350 400 600 800 900
Wavelength (nm)
Chemistry
This is an example of the analysis of colored cellophane tape. Materials can be
confirmed quantitatively by using LabSolutions UV-Vis and color measurement
software.
100 0.90
0.80
80 0.70
0.60
Transmittance (%)
60 0.50
y
0.40
40 0.30
0.20
20 0.10
0.00
0.00 0.10 0.20 0.30 0.40 0.50 0.60 0.70 0.80
0 x
Accessories
UV-1900i
UV-VIS Spectrophotometer 9
Expanded Memory (P/N 207-23119-41) Test Tube Holder (P/N 207-23510-41)
The UV-1900i main unit can store up to 999 sets of data. Holds test tube instead of
The saved data can be read out from a PC. sample compartment.
(A network connection is required for data readout.) Specifications:
Outside diameter: φ15 to 22 mm
Film Holder ( P/N 204-58909) Height: 75 to 115 mm
Note: Test tube is not included.
Used in transmittance
measurement of thin samples
such as films and filters. It Multi-Cell Sample Compartment (P/N 206-69160-41)
holds the samples for
analysis. Holds up to six 10-mm square
cells on the sample side. No
temperature control capability.
Long-Path Rectangular Cell Holder (P/N 204-23118-01) Number of cells: 6 on the sample side
Holds two rectangular cells with an optical 1 on the reference side path length of 10, 20, 30, 50, 70, or 100 mm. Note: Square
cells are not included, please purchase separately. Sipper Unit
10
Standard Software: LabSolutions UV-Vis
The combination of the UV-1900i, offering lower stray light levels and higher accuracy,
with LabSolutions UV-Vis software, which achieves labor-saving measurements,
provides a more convenient analytical environment.
Setting Parameters
From Measurement to Data Output
and automatic measurements spent outputting or analyzing data can also be reduced by (optional) enable measurements to be performed using
operations. time or saving data as text. The software can also automatically
UV-1900i
UV-VIS Spectrophotometer 11
perform post-processing of measured data, such as
12
Automatic Spectral Evaluation Stronger Data Management
Data Management
Optional Software
LabSolutions DB UV-Vis
LabSolutions CS UV-Vis
Database Management
Managing data in a database can prevent the overwriting or
deletion of analysis data. Furthermore, during postrun
analysis, the data can be managed using version numbers,
so there are no concerns about overwriting the data.
Postrun Postrun
Analysis analysis analysis
Ver. 1 Ver. 2 Ver. 3
In the report creation window, reports can either be prepared based Reduces operator errors.
on a previously specified report format or freely laid out based on
various parameters, data, or other elements.
UV-1900i
UV-VIS Spectrophotometer 13
Advanced Regulatory Compliance
Full Support for Pharmacopeia, GLP/GMP, FDA 21 CFR Part 11 and Other Regulations
Instrument Validation Functions Compliant with JP, USP, and EP
This instrument can not only run checks for nine JIS items, but also those stipulated in the Japanese Pharmacopoeia (JP), United States Pharmacopeia
(USP), and the European Pharmacopoeia (EP). Naturally, the hardware is also compliant with the specifications required by each Pharmacopeia. In
addition, the check conditions can be saved. As a result, once the conditions are saved, checks can be performed easily just by calling them up as
needed. Check results can also be saved.
Main Screen
14
Compatible with Validation from PC Software
Validation can be implemented with PC software by using the optionally available UV validation software.
In addition to simplifying daily inspections, this makes instrument performance checks and records management easier, enabling more secure
regulatory compliance.
• Inspection results can not only be printed but also saved to a file, so the • The user can select confirmation of instrument performance indicators results can be called up
later for confirmation. as per JIS K0115 General rules for molecular absorptiometric analysis, as
• The inspection parameters can also be saved to separate files for well as the general test methods in the Japanese Pharmacopeia, USP periodic and routine
inspections, and then called up for use. and various EP inspections. (Order inspection jigs and reagents separately.)
Support for FDA 21 CFR Part 11, PIC/S GMP Guidelines and Other Regulations and Guidelines
Ensuring the integrity of data (database management), including the user management, user authority management, and data audit trails required for
compliance with FDA 21 CFR Part 11, PIC/S GMP guidelines, and other ER/ES regulations, is possible.
UV-1900i
UV-VIS Spectrophotometer 15
UV-1900i
UV-1900i Website
https://www.shimadzu.com/an/molecular_spectro/uv/uv-1900/index.html
-Automated support functions utilizing digital technology, such as M2M, IoT , and Artificial Intelligence
(AI), that enable higher productivity and maximum reliability.
-Allows a system to monitor and diagnose itself, handle any issues during data acquisition without user
input, and automatically behave as if it were operated by an expert. -Supports the acquisition of high
quality, reproducible data regardless of an operator’s skill
level for both routine and
demanding applications.
www.shimadzu.com/an/
LabSolutions and Analytical Intelligence Logo are trademarks of Shimadzu
Corporation.
TrayCell is a registered trademark of Hellma GmbH & Co. KG. in Germany.
Excel is a registered trademark or trademark of the Microsoft Corporation in the
USA and other countries.
For Research Use Only. Not for use in
diagnostic procedures.
This publication may contain
references to products that are not
available in your country. Please
contact us to check the availability of
these products in your country.
Company names, products/service
names and logos used in this
publication are trademarks and trade
names of Shimadzu Corporation, its
subsidiaries or its affiliates, whether
or not they are used with trademark
symbol “TM” or “®”.
Third-party trademarks and trade
names may be used in this publication
to refer to either the entities or their
products/services, whether or not
they are used with trademark symbol
“TM” or “®”.
Shimadzu disclaims any proprietary
interest in trademarks and trade
names other than its own.