User Manual Solar (Abacus) 110v

The document provides descriptions of various displays, indications, and alerts that may appear on a solar charging system. It includes 17 items that describe: 1) Displays related to solar charging current, capacity, daily and total energy savings 2) Messages regarding the charging mode, battery type selected, and system status 3) Alerts for issues like a blown fuse, overload, short circuit, high/low battery voltage, overheating, incorrect wiring, etc. and the recommended actions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
105 views

User Manual Solar (Abacus) 110v

The document provides descriptions of various displays, indications, and alerts that may appear on a solar charging system. It includes 17 items that describe: 1) Displays related to solar charging current, capacity, daily and total energy savings 2) Messages regarding the charging mode, battery type selected, and system status 3) Alerts for issues like a blown fuse, overload, short circuit, high/low battery voltage, overheating, incorrect wiring, etc. and the recommended actions.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Sol Chg _ _ .

_ A Display Solar Charging Current OK- No Action Required


8. SOLAR CAPACITY Display Solar Current Capacity No Action Required
Sol Load _ _ . _ A Display Solar Load Current
__._A
4. TODAY'S SAVING Display Current Day Solar Saving OK- No Action Required
9. !! UPS ALERT !! Mains Fuse Blown Replace the fuse
_ _ _ Kwh
Mains Fuse Blown
TOTAL SAVING Display Total Solar Saving
10. !! UPS ALERT !! Mains Overload Reduce the Load, Switch OFF &
_ _ _ Kwh ON again
Grid Overload
5. NARROW BAND SELECTED UPS Mode is ON No Action Required
11. !! UPS ALERT !! System Output is Short Circuited Call the nearby electrician to
WIDE BAND SELECTED UPS Mode is OFF No Action Required
check household wiring
Short Circuit
6. SMF BATTERY SELECTED SMF Battery is Selected. The No Action Required
S.No. Display on LCD Indication Action Maximum Battery Voltage for SMF
12. !! UPS ALERT !! Battery High Cut Disconnect Mains & Solar Both.
Battery is 13.8V and this cannot be
1. SYSTEM ON Inverter/UPS ON No Action Required changed.
Battery High
Batt Volt _ _ ._ V Display Battery Voltage TUBULAR BATTERY SELECTED Tubular Battery is Selected. Maximum No Action Required
13. !! UPS ALERT !! Over Temperat ure Protection Disconnect Solar
Battery voltage is settable for Tubular
GRID AVAILABLE Mains Grid Available Battery which can be set from 14.0V
Over Temperature Switch OFF Inverter
to 15.0V.
Input Volt _ _ _ V Display Input Voltage
14. !! UPS ALERT !! UPS Output Voltage out of Range Switch OFF Inverter
7. HYBRID MODE SELECTED Hybrid Mode is selected for Solar Use. No Action Required
SYSTEM OFF Inverter/UPS OFF No Action Required
In Hybrid Mode Load is never shift to
Output Not OK
Solar and only Battery Charging is
Batt Volt _ _ ._ V Display Battery Voltage 15. !! UPS ALERT !! Battery Low Cut Switch Off the Load & wait for
done from solar.
mains to resume
GRID FAIL Mains Grid Fail Battery Low
Battery is charged with Maximum
Solar Chg current set with the help of 16. !! UPS ALERT !! Inverter/UPS Overload Reduce the Load, Switch OFF &
Input Volt _ _ _ V Display Input Voltage
Solar & Mains Current both. ON again
Overload
CHARGING MODE 1 Constant CurrentCharging OK- No Action Required
PCU LIGHT MODE SELECTED PCU Light Mode is selected for Solar No Action Required 17. !! UPS ALERT !! PV Wire reverse connected Connect PV with Correct Polarity
2. Grid Chg _ _ ._ A Display Mains Charging Current Use.
PV Reverse
Load ON Grid Load running on Mains In PCU Mode Load shift to Solar when
Extra Solar Current is greater than 4A
O/P Volt _ _ _ V Display Output Voltage and Battery Voltage is Greater than
(Set Max Battery Voltage – 0.5V) or
CHARGING MODE2 Constant Battery Voltage Charging OK- No Action Required Battery is full Charged and System is
ON.
Grid Chg _ _ ._ A Display Mains Charging Current
Battery Charging is shared by solar &
Load ON Solar Load running on Solar Mains.

O/P Volt _ _ _ V Display Output Voltage PCU ULTRA MODE SELECTED PCU Ultra mode has same No Action Required
functionality as PCU light mode for
CHARGING MODE3 Trickle Charging On OK- No Action Required Solar use.

BATT FULL CHARGE Battery Full Charged Declared This mode has added feature of no
charging from Grid to maximize the
Load ON Sol & Batt Load running on Both Solar & Battery power saving. The Battery charging is
done only by Solar power.
O/P Volt _ _ _ V Display Output Voltage
Grid charging is enabled only when
CHARGING OFF OK- No Action Required
Battery voltage is below the Battery
Battery Charging OFF
low cut voltage and when battery
Grid Chg 0 0 .0 A

Load ON Battery Load running on Battery

O/P Volt _ _ _ V Display Output Voltage

!! UPS ALERT !! Mains & Solar Charging Fail Disconnect Mains & Solar Both.

Batt Charge Fail

3. Batt Load _ _ _ % Display Load Percentage On Battery OK- No Action Required

Solar Load _ _ _ % Display Load Percentage On Solar

Parameters Normal Mode UPS Mode

Mains AC Lower Voltage Limit 50 ± 5 VAC per Phase 90 ± 5 VAC per Phase

Mains AC Lower Recovery Voltage 55 ± 5 VAC per Phase 95 ± 5 VAC per Phase

Mains AC Higher Voltage Limit 145 ± 5 VAC per Phase 130 ± 5 VAC per Phase

Mains AC Higher Recovery Voltage 140 ± 5 VAC per Phase 125 ± 5 VAC per Phase

Output Voltage with full load in UPS/Normal Mode 220 ± 7 VAC Phase to Phase

Battery Low Cut Voltage (Settable) SMF Battery: 11.0 ± 0.2V (Per Battery), Default
Tubular Battery: 10.6 ± 0.2V (Per Battery), Default

Mains O/P Frequency Same as Input

UPS O/P Frequency 60 ± 1.0 Hz

Solar Charge Controller

Technology DSP based Intelligent Battery Charging & Charge Sharing with
Mains.

Charge Controller Type PWM Based

Peak Solar PV Current 50/70 Amps

Solar Battery Charging Current (Settable) 30 Amps (Default)

Grid Reconnect Battery Voltage (Settable) 12.0 V (Default)

PV Reverse Polarity Protection Available

Reverse Current Flow to PV Protection Available

Battery Charging

Battery Charging Voltage Range 50 to 145 V per Phase 90 to 130 V per Phase

Mains Charging Current 5 – 18 A(R ange) , 15A (Default)

Trickle Charging Current Limit 3A± 0.3A

Maximum Battery Voltage (Settable for Tubular SMF Battery: 14.0 (per Battery)
Battery )
Tubular Battery: 14.4 (per Battery),(Default)

Float Voltage SMF Battery: 13.7 ± 0.2V (per Battery)