Manhole Design: N RN RN

The document discusses calculations for the thickness and area of a nozzle and provides specifications for the design of a manhole on a vessel. It determines the calculated thickness of the nozzle to be 3.34mm and its cross-sectional area to be 0.0012389m2. It then specifies a manhole diameter of 0.5m made of carbon steel with an inward height of 15mm and outward height of 35mm located at the lower cross section of the vessel shell. It also notes that the manhole opening requires reinforcement and there is enough excess area on the components to reinforce it without additional work.

Uploaded by

Eshet Shumet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
33 views

Manhole Design: N RN RN

The document discusses calculations for the thickness and area of a nozzle and provides specifications for the design of a manhole on a vessel. It determines the calculated thickness of the nozzle to be 3.34mm and its cross-sectional area to be 0.0012389m2. It then specifies a manhole diameter of 0.5m made of carbon steel with an inward height of 15mm and outward height of 35mm located at the lower cross section of the vessel shell. It also notes that the manhole opening requires reinforcement and there is enough excess area on the components to reinforce it without additional work.

Uploaded by

Eshet Shumet
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 2

A2=2(2.

5t) (tn-trn) tr
Where trn- calculated thickness of nozzle
/
For nozzle, trn=PRn SE-0.6P .
trn=(1.3125*106*0.29) / (1.275*10 *0.9-0.6*1.3125*10 )
8 6

trn=0.00334m=3.34mm
A2=2*2.5*1.66(2.1-)
A3=2(tn-c) tr*h
where h -inside height, h=5.25mm
A3=2(2.1-2)*5.34*5.25
A3=5.607mm2
A=dtrf where d- diameter of nozzle
A=0.116*2*0.00534*1
A=0.0012389m2.

• Manhole Design

From the ASME standard of the vessel which have internal diameter exceed 10in must have one
manhole and its size also based on shoulder of man, so
We have taken the diameter 0.5m. The material is carbon steel.

Thickness analysis
tm=

/
trn=(PRn SE-0.6P)+CA
trn=((1.3125*106*0.29) / (1.275*10 *0.9-0.6*1.3125*10 ) )+2
8 6
trn=5.34mm.

Approach to the standard tm=6mm


Inward height of the manhole

L=2.5tm
L=2.5*6
L=15mm.
Out ward height of the manhole we assume L=35mm like the nozzle height. The Position of the
manhole at the lower cross section of the vessel shell for the safety.
The Manhole opening also needs reinforcement so we must be reinforcing it.
The excess area available on the components is enough to reinforce without any wedding of pad.

• Manhole opening reinforcement

• Excess area in shell


A12(Jt-ftr) (t+tm)
Where:
t-actual thickness of shell
tr-calculated thickness of shell

tm-actual thickness of manhole