Design Notes and Assumptions
Design Notes and Assumptions
1 COVER SHEET 01
2 INDEX 02
3 DESIGN DATA 03
7 Radiography NIL
8 Service FOAM
4. NOTES AND ASSUMPTION
1 Base metal ID has been considered as 1000 mm as per datasheet
4 Below properties for Insulation & Fire proofing are as per Specification
Site Class : E
Component Amplification factor [Rp] : 2.5
Component Force factor [Ar] : 2.5
Acceleration Sa(0.2) :0.1920
Acceleration Sa(0.5) :0.1260
Acceleration Sa(1.0) :0.0720
Acceleration Sa(2.0) :0.0360
7 Top plate is design as per Good Engineering Practice and Roorks Hand
Book. (Refer Page 71 of Design Report)
Bottom Plate is design as per Good Engineering Practice.
8 (Refer Page 71 of Design Report)
9 Fluid Desnity assumed as 1100 Kg/m^3.
CLIENT NAME
Allowable
Allowable Min Yield at
Allowable Yield stress Min UTS at
Material stress at room room Stress Ref. Page no of Code
Component stress at for room
Specification temperature Temperature 40 Ratio :Sec II (D) Metric
90°C Hydrotest 40 Temperature
40°C °C
°C
A B C 0.9*C E B/A
Line No./Table
MPa (g) MPa (g) MPa (g) MPa (g) MPa (g) No./Page No.
10/1A/17-19
Shell SA 106 GR B 118.0 118.0 241.0 216.9 415.0 1.000 &
44/Y1/658-660
10/1A/17-19
Nozzle Neck Pipe SA 106 GR B 118.0 118.0 241.0 216.9 415.0 1.000 &
44/Y1/658-661
12/1A/16-19
Head / Pipe Fittings /
SA 234 Gr.WPB 118.0 118.0 241.0 216.9 415.0 1.000 &
Elbow
46/Y1/658-661
33/1A/20-23
Saddle Support SA 516 Gr. 70 138.0 138.0 262.0 235.8 485.0 1.000 &
24/Y1/666-669
28/3/398-401
External Bolting & SA 193 Gr. B7 /
130.0 138.0 517.0 465.3 690.0 1.062 &
Nuts SA 194 Gr. 2H
12/Y1/636-638
Lowest stress ratio(LSR)= 1.000 (Except Bolting)
0
CONDITION APPLICABILITY
Yes
2) The completed vessel shall be hydrostatically tested per UG-99( b ).
Yes
4) Themal & Mechanical loadings are not a controlling design requirement.
Yes
5) Cyclical loading is not a controlling design requirement.
No. Component Identifier Spec. No. Group Curve Thk. per rule
( mm ) No. ( mm ) UCS-66(a)
Notes:
1) As per UW-11 (a) (2) of ASME SEC VIII Div-1, minimum thickness of components above which full radiography of butt welded
joints is mandatory is 38 mm.
2) As per Datasheet sheet 100% RT For Shell & Heads shall be carried out for all butt welded joints.
PFHT based
PWHT based on Rf % E % E on
Sr. t ID
Component Material P-No P-No & Thickness Elongation Elongation Strain
No. (mm) (mm) (mm) (ASME) (32-SAMSS-004) Elongation.
"B" (Note-2)
1 Head SA 516 Gr.70 P1 10.000 Not Required 1981.0 342 2.194 26.236 Required
2 Shell SA 516 Gr.70 P1 12.000 Not Required 1981.0 997 0.602 0.602 Not Required
Fabricated
5 Pipe for SA 516 Gr.70 P1 10.0 Not required 590.0 305 1.639 1.639 Not required
Nozzle-M1
Notes:
1 As per note (b) (1) Table UCS-56-1 of ASME Sec VIII Div. 1 for P1 materials, PWHT, Postweld heat treatment is mandatory
for welded joints of all thickness above 38 mm.
2 As per UCS-79 of ASME Sec VIII Div. 1,for cold formed components, Stress relieving is required after forming when the
extreme fiber elongation (strain) exceeds 5 % from the as-rolled condition.
Conclusion:
1 Since, the extreme fiber elongation (strain) is greater than 10%, Stress relieving is required after forming for dishend.
Hence 32-SAMSS-004 requirement is complied.
POST WELD HEAT TREATMENT REQUIREMENT (UCS-56,UCS-79) AND 32-SAMSS-004
2 As verified above, PWHT is not required as per code.
EXTERNAL PRESSURE AND MISCELLANEOUS LOADS CALCULATION
(As per Good Engineering Practice)
Min. hydro test pressure for the vessel at top in Horizontal condition :
= 1.3 x P x R
For induced stresses during hydro test, Refer page-XXX of design report.
LARSEN & TOUBRO HEAVY ENGINEERING LLC
SOHAR WORKS, OMAN
= 1.3 x P x LSR
For induced stresses during site hydro test, Refer page-41 of design report.
TEMPLATE SIZE FOR SHELL & HEAD (AS PER UG 80 & 81)
LEFT &
SHELL
SECTION (UG-80)
RIGHT HEAD Remark
(UG-81)
Nominal thk-Corrosion
allowance 12.00 10.00
Thickness, t (mm)
W/HD2 = 1330.18
Since W/HD^2 ratio is greater than 400. Hence Vortex shadding is Not Applicable
10 Concusion :
Since H/D ratio is less than 15 and W/HD^2 ratio is greater than 400. Hence
Vortex shadding is Not Applicable
NODE DESCRIPTION FOR VESSEL
Node Description
20-30 Shell-1