Plan de Détails 2: Assemblage Poteau HEA 280-Traverse 360

This document provides details on the assembly of a steel frame connection between a HEA 280 column and IPE 360 beam. It includes the geometry, materials, bolts, plates and stiffeners used. It also specifies loads and provides calculations of the resistances of the beam, column, and connection based on Eurocode standards. The key resistances calculated are 435 kN*m for the beam bending resistance, 473.5 kN for the column web panel shear resistance, and 834.8 kN for the column web transverse compression resistance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
112 views9 pages

Plan de Détails 2: Assemblage Poteau HEA 280-Traverse 360

This document provides details on the assembly of a steel frame connection between a HEA 280 column and IPE 360 beam. It includes the geometry, materials, bolts, plates and stiffeners used. It also specifies loads and provides calculations of the resistances of the beam, column, and connection based on Eurocode standards. The key resistances calculated are 435 kN*m for the beam bending resistance, 473.5 kN for the column web panel shear resistance, and 834.8 kN for the column web transverse compression resistance.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 9

Plan de détails 2 : Assemblage Poteau HEA 280- Traverse 360

Vue en perspective

GENERAL : ASSEMBLAGE POTEAU HEA 280-TRAVAERSE 360


Connection no.: 9
Connection name: Frame knee

GEOMETRY

COLUMN
Section: HEA 280
= -90,0 [Deg] Inclination angle
hc = 270 [mm] Height of column section
bfc = 280 [mm] Width of column section
twc = 8 [mm] Thickness of the web of column section
tfc = 13 [mm] Thickness of the flange of column section
rc = 24 [mm] Radius of column section fillet
Ac = 9730 [mm2] Cross-sectional area of a column
Ixc = 136700000 [mm4] Moment of inertia of the column section
Material: S275
fyc = 275,00 [MPa] Resistance

BEAM
Section: IPE 360
= 18,0 [Deg] Inclination angle
hb = 360 [mm] Height of beam section
bf = 170 [mm] Width of beam section
twb = 8 [mm] Thickness of the web of beam section
tfb = 13 [mm] Thickness of the flange of beam section
rb = 18 [mm] Radius of beam section fillet
rb = 18 [mm] Radius of beam section fillet
Ab = 7270 [mm2] Cross-sectional area of a beam
Ixb = 162700000 [mm4] Moment of inertia of the beam section
Material: S275
fyb = 275,00 [MPa] Resistance

BOLTS
The shear plane passes through the UNTHREADED portion of the bolt.
d= 16 [mm] Bolt diameter
Class = 3.6 Bolt class
FtRd = 33,91 [kN] Tensile resistance of a bolt
nh = 2 Number of bolt columns
nv = 4 Number of bolt rows
h1 = 53 [mm] Distance between first bolt and upper edge of front plate
Horizontal spacing ei = 70 [mm]
Vertical spacing pi = 140;140;140 [mm]

PLATE
hp = 600 [mm] Plate height
bp = 170 [mm] Plate width
tp = 20 [mm] Plate thickness
Material: S275
fyp = 275,00 [MPa] Resistance

UPPER STIFFENER
wu = 170 [mm] Plate width
tfu = 12 [mm] Flange thickness
hu = 140 [mm] Plate height
twu = 8 [mm] Web thickness
lu = 300 [mm] Plate length
= 9,4 [Deg] Inclination angle
Material: S275
fybu = 275,00 [MPa] Resistance

COLUMN STIFFENER
Upper
hsu = 244 [mm] Stiffener height
bsu = 136 [mm] Stiffener width
thu = 8 [mm] Stiffener thickness
Material: STEEL 43-245
fysu = 245,00 [MPa] Resistance
Lower
hsd = 244 [mm] Stiffener height
bsd = 136 [mm] Stiffener width
hsd = 244 [mm] Stiffener height
thd = 8 [mm] Stiffener thickness
Material: STEEL 43-245
fysu = 245,00 [MPa] Resistance

FILLET WELDS
aw = 5 [mm] Web weld
af = 8 [mm] Flange weld
as = 5 [mm] Stiffener weld
afu = 5 [mm] Horizontal weld

MATERIAL FACTORS
M0 = 1,00 Partial safety factor [2.2]
M1 = 1,00 Partial safety factor [2.2]
M2 = 1,25 Partial safety factor [2.2]
M3 = 1,25 Partial safety factor [2.2]

LOADS
Ultimate limit state
Case: Manual calculations.
Mb1,Ed = 50,00 [kN*m] Bending moment in the right beam

RESULTS

BEAM RESISTANCES
BENDING - PLASTIC MOMENT (WITHOUT BRACKETS)
Wplb = 1019000 [mm3] Plastic section modulus EN1993-1-1:[6.2.5.(2)]
Mb,pl,Rd = Wplb fyb / M0
Mb,pl,Rd = 280,22 [kN*m] Plastic resistance of the section for bending (without stiffeners) EN1993-1-1:[6.2.5.(2)]
BENDING ON THE CONTACT SURFACE WITH PLATE OR CONNECTED ELEMENT
Wpl = 1581894 [mm3] Plastic section modulus EN1993-1-1:[6.2.5]
Mcb,Rd = Wpl fyb / M0
Mcb,Rd = 435,02 [kN*m] Design resistance of the section for bending EN1993-1-1:[6.2.5]
FLANGE AND WEB - COMPRESSION
Mcb,Rd = 435,02 [kN*m] Design resistance of the section for bending EN1993-1-1:[6.2.5]
hf = 506 [mm] Distance between the centroids of flanges [6.2.6.7.(1)]
Fc,fb,Rd = Mcb,Rd / hf
Fc,fb,Rd = 860,12 [kN] Resistance of the compressed flange and web [6.2.6.7.(1)]

COLUMN RESISTANCES
WEB PANEL - SHEAR
Mb1,Ed = 50,00 [kN*m] Bending moment (right beam) [5.3.(3)]
Mb2,Ed = 0,00 [kN*m] Bending moment (left beam) [5.3.(3)]
Vc1,Ed = 0,00 [kN] Shear force (lower column) [5.3.(3)]
Vc2,Ed = 0,00 [kN] Shear force (upper column) [5.3.(3)]
z= 399 [mm] Lever arm [6.2.5]
Vwp,Ed = (Mb1,Ed - Mb2,Ed) / z - (Vc1,Ed - Vc2,Ed) / 2
Vwp,Ed = 125,27 [kN] Shear force acting on the web panel [5.3.(3)]
Avs = 3178 2
[mm ] Shear area of the column web EN1993-1-1:[6.2.6.(3)]
Avc = 3178 [mm2] Shear area EN1993-1-1:[6.2.6.(3)]
ds = 449 [mm] Distance between the centroids of stiffeners [6.2.6.1.(4)]
Mpl,fc,Rd = 3,25 [kN*m] Plastic resistance of the column flange for bending [6.2.6.1.(4)]
Mpl,stu,Rd = 1,10 [kN*m] Plastic resistance of the upper transverse stiffener for bending [6.2.6.1.(4)]
Avs = 3178 [mm2] Shear area of the column web EN1993-1-1:[6.2.6.(3)]
Mpl,stl,Rd = 1,10 [kN*m] Plastic resistance of the lower transverse stiffener for bending [6.2.6.1.(4)]
Vwp,Rd = 0.9 ( Avs*fy,wc ) / (3 M0) + Min(4 Mpl,fc,Rd / ds , (2 Mpl,fc,Rd + Mpl,stu,Rd + Mpl,stl,Rd) / ds)
Vwp,Rd = 473,50 [kN] Resistance of the column web panel for shear [6.2.6.1]
Vwp,Ed / Vwp,Rd ≤ 1,0 0,26 < 1,00 verified (0,26)
WEB - TRANSVERSE COMPRESSION - LEVEL OF THE BEAM BOTTOM FLANGE
Bearing:
twc = 8 [mm] Effective thickness of the column web [6.2.6.2.(6)]
beff,c,wc = 261 [mm] Effective width of the web for compression [6.2.6.2.(1)]
Avc = 3178 [mm2] Shear area EN1993-1-1:[6.2.6.(3)]
= 0,80 Reduction factor for interaction with shear [6.2.6.2.(1)]
com,Ed = 0,00 [MPa] Maximum compressive stress in web [6.2.6.2.(2)]
kwc = 1,00 Reduction factor conditioned by compressive stresses [6.2.6.2.(2)]
As = 1866 [mm2] Area of the web stiffener EN1993-1-1:[6.2.4]
Fc,wc,Rd1 =  kwc beff,c,wc twc fyc / M0 + As fys / M0
Fc,wc,Rd1 = 916,82 [kN] Column web resistance [6.2.6.2.(1)]
Buckling:
dwc = 196 [mm] Height of compressed web [6.2.6.2.(1)]
p = 0,97 Plate slenderness of an element [6.2.6.2.(1)]
= 0,82 Reduction factor for element buckling [6.2.6.2.(1)]
s = 2,39 Stiffener slenderness EN1993-1-1:[6.3.1.2]
s = 1,00 Buckling coefficient of the stiffener EN1993-1-1:[6.3.1.2]
Fc,wc,Rd2 =  kwc  beff,c,wc twc fyc / M1 + As s fys / M1
Fc,wc,Rd2 = 834,78 [kN] Column web resistance [6.2.6.2.(1)]
Final resistance:
Fc,wc,Rd,low = Min (Fc,wc,Rd1 , Fc,wc,Rd2)
Fc,wc,Rd = 834,78 [kN] Column web resistance [6.2.6.2.(1)]

GEOMETRICAL PARAMETERS OF A CONNECTION


EFFECTIVE LENGTHS AND PARAMETERS - COLUMN FLANGE
Nr m mx e ex p leff,cp leff,nc leff,1 leff,2 leff,cp,g leff,nc,g leff,1,g leff,2,g
1 12 - 105 - 140 74 125 74 125 177 106 106 106
2 12 - 105 - 140 74 178 74 178 280 140 140 140
3 12 - 105 - 140 74 178 74 178 280 140 140 140
4 12 - 105 - 140 74 117 74 117 177 98 98 98
EFFECTIVE LENGTHS AND PARAMETERS - FRONT PLATE
Nr m mx e ex p leff,cp leff,nc leff,1 leff,2 leff,cp,g leff,nc,g leff,1,g leff,2,g
1 25 - 50 - 140 159 198 159 198 220 186 186 186
2 25 - 50 - 140 159 164 159 164 280 140 140 140
3 25 - 50 - 140 159 164 159 164 280 140 140 140
4 25 - 50 - 140 159 164 159 164 220 152 152 152
m – Bolt distance from the web
mx – Bolt distance from the beam flange
e – Bolt distance from the outer edge
ex – Bolt distance from the horizontal outer edge
p – Distance between bolts
leff,cp – Effective length for a single bolt in the circular failure mode
leff,nc – Effective length for a single bolt in the non-circular failure mode
leff,1 – Effective length for a single bolt for mode 1
leff,2 – Effective length for a single bolt for mode 2
leff,cp,g – Effective length for a group of bolts in the circular failure mode
leff,nc,g – Effective length for a group of bolts in the non-circular failure mode
leff,1,g – Effective length for a group of bolts for mode 1
leff,2,g – Effective length for a group of bolts for mode 2
CONNECTION RESISTANCE FOR BENDING
Ft,Rd = 33,91 [kN] Bolt resistance for tension [Table 3.4]
Bp,Rd = 202,31 [kN] Punching shear resistance of a bolt [Table 3.4]
Ft,fc,Rd – column flange resistance due to bending
Ft,wc,Rd – column web resistance due to tension
Ft,ep,Rd – resistance of the front plate due to bending
Ft,wb,Rd – resistance of the web in tension
Ft,fc,Rd = Min (FT,1,fc,Rd , FT,2,fc,Rd , FT,3,fc,Rd) [6.2.6.4] , [Tab.6.2]
Ft,wc,Rd =  beff,t,wc twc fyc / M0 [6.2.6.3.(1)]
Ft,ep,Rd = Min (FT,1,ep,Rd , FT,2,ep,Rd , FT,3,ep,Rd) [6.2.6.5] , [Tab.6.2]
Ft,wb,Rd = beff,t,wb twb fyb / M0 [6.2.6.8.(1)]
RESISTANCE OF THE BOLT ROW NO. 1
Ft1,Rd,comp - Formula Ft1,Rd,comp Component
Ft1,Rd = Min (Ft1,Rd,comp) 67,82 Bolt row resistance
Ft,fc,Rd(1) = 67,82 67,82 Column flange - tension
Ft,wc,Rd(1) = 159,54 159,54 Column web - tension
Ft,ep,Rd(1) = 67,82 67,82 Front plate - tension
Ft,wb,Rd(1) = 350,32 350,32 Beam web - tension
Bp,Rd = 404,62 404,62 Bolts due to shear punching
Vwp,Rd/ = 473,50 473,50 Web panel - shear
Fc,wc,Rd = 834,78 834,78 Column web - compression
Fc,fb,Rd = 860,12 860,12 Beam flange - compression
RESISTANCE OF THE BOLT ROW NO. 2
Ft2,Rd,comp - Formula Ft2,Rd,comp Component
Ft2,Rd = Min (Ft2,Rd,comp) 67,82 Bolt row resistance
Ft,fc,Rd(2) = 67,82 67,82 Column flange - tension
Ft,wc,Rd(2) = 159,54 159,54 Column web - tension
Ft,ep,Rd(2) = 67,82 67,82 Front plate - tension
Ft,wb,Rd(2) = 350,32 350,32 Beam web - tension
Bp,Rd = 404,62 404,62 Bolts due to shear punching
Vwp,Rd/ - ∑11 Fti,Rd = 473,50 - 67,82 405,67 Web panel - shear
Fc,wc,Rd - ∑11 Ftj,Rd = 834,78 - 67,82 766,95 Column web - compression
Fc,fb,Rd - ∑11 Ftj,Rd = 860,12 - 67,82 792,30 Beam flange - compression
Ft,fc,Rd(2 + 1) - ∑11 Ftj,Rd = 135,65 - 67,82 67,82 Column flange - tension - group
Ft,wc,Rd(2 + 1) - ∑11 Ftj,Rd = 442,14 - 67,82 374,32 Column web - tension - group
Ft,ep,Rd(2 + 1) - ∑11 Ftj,Rd = 135,65 - 67,82 67,82 Front plate - tension - group
Ft,wb,Rd(2 + 1) - ∑11 Ftj,Rd = 716,86 - 67,82 649,04 Beam web - tension - group
Additional reduction of the bolt row resistance
Ft2,Rd = Ft1,Rd h2/h1
Ft2,Rd = 47,58 [kN] Reduced bolt row resistance [6.2.7.2.(9)]
RESISTANCE OF THE BOLT ROW NO. 3
Ft3,Rd,comp - Formula Ft3,Rd,comp Component
Ft3,Rd = Min (Ft3,Rd,comp) 67,82 Bolt row resistance
Ft,fc,Rd(3) = 67,82 67,82 Column flange - tension
Ft,wc,Rd(3) = 159,54 159,54 Column web - tension
Ft,ep,Rd(3) = 67,82 67,82 Front plate - tension
Ft,wb,Rd(3) = 350,32 350,32 Beam web - tension
Bp,Rd = 404,62 404,62 Bolts due to shear punching
Vwp,Rd/ - ∑12 Fti,Rd = 473,50 - 115,41 358,09 Web panel - shear
Fc,wc,Rd - ∑12 Ftj,Rd = 834,78 - 115,41 719,37 Column web - compression
Fc,fb,Rd - ∑12 Ftj,Rd = 860,12 - 115,41 744,71 Beam flange - compression
Ft,fc,Rd(3 + 2) - ∑22 Ftj,Rd = 135,65 - 47,58 88,06 Column flange - tension - group
Ft,wc,Rd(3 + 2) - ∑22 Ftj,Rd = 480,16 - 47,58 432,58 Column web - tension - group
Ft3,Rd,comp - Formula Ft3,Rd,comp Component
Ft,fc,Rd(3 + 2 + 1) - ∑21 Ftj,Rd = 203,47 - 115,41 88,06 Column flange - tension - group
Ft,wc,Rd(3 + 2 + 1) - ∑21 Ftj,Rd = 569,02 - 115,41 453,61 Column web - tension - group
Ft,ep,Rd(3 + 2) - ∑22 Ftj,Rd = 135,65 - 47,58 88,06 Front plate - tension - group
Ft,wb,Rd(3 + 2) - ∑22 Ftj,Rd = 616,00 - 47,58 568,42 Beam web - tension - group
Ft,ep,Rd(3 + 2 + 1) - ∑21 Ftj,Rd = 203,47 - 115,41 88,06 Front plate - tension - group
Ft,wb,Rd(3 + 2 + 1) - ∑21 Ftj,Rd = 1024,86 - 115,41 909,46 Beam web - tension - group
Additional reduction of the bolt row resistance
Ft3,Rd = Ft1,Rd h3/h1
Ft3,Rd = 27,34 [kN] Reduced bolt row resistance [6.2.7.2.(9)]
RESISTANCE OF THE BOLT ROW NO. 4
Ft4,Rd,comp - Formula Ft4,Rd,comp Component
Ft4,Rd = Min (Ft4,Rd,comp) 67,82 Bolt row resistance
Ft,fc,Rd(4) = 67,82 67,82 Column flange - tension
Ft,wc,Rd(4) = 159,54 159,54 Column web - tension
Ft,ep,Rd(4) = 67,82 67,82 Front plate - tension
Ft,wb,Rd(4) = 350,32 350,32 Beam web - tension
Bp,Rd = 404,62 404,62 Bolts due to shear punching
Vwp,Rd/ - ∑13 Fti,Rd = 473,50 - 142,75 330,74 Web panel - shear
Fc,wc,Rd - ∑13 Ftj,Rd = 834,78 - 142,75 692,02 Column web - compression
Fc,fb,Rd - ∑13 Ftj,Rd = 860,12 - 142,75 717,37 Beam flange - compression
Ft,fc,Rd(4 + 3) - ∑33 Ftj,Rd = 135,65 - 27,34 108,30 Column flange - tension - group
Ft,wc,Rd(4 + 3) - ∑33 Ftj,Rd = 432,36 - 27,34 405,02 Column web - tension - group
Ft,fc,Rd(4 + 3 + 2) - ∑32 Ftj,Rd = 203,47 - 74,93 128,54 Column flange - tension - group
Ft,wc,Rd(4 + 3 + 2) - ∑32 Ftj,Rd = 563,61 - 74,93 488,68 Column web - tension - group
Ft,fc,Rd(4 + 3 + 2 + 1) - ∑31 Ftj,Rd = 271,30 - 142,75 128,54 Column flange - tension - group
Ft,wc,Rd(4 + 3 + 2 + 1) - ∑31 Ftj,Rd = 622,10 - 142,75 479,35 Column web - tension - group
Ft,ep,Rd(4 + 3) - ∑33 Ftj,Rd = 135,65 - 27,34 108,30 Front plate - tension - group
Ft,wb,Rd(4 + 3) - ∑33 Ftj,Rd = 642,26 - 27,34 614,91 Beam web - tension - group
Ft,ep,Rd(4 + 3 + 2) - ∑32 Ftj,Rd = 203,47 - 74,93 128,54 Front plate - tension - group
Ft,wb,Rd(4 + 3 + 2) - ∑32 Ftj,Rd = 950,26 - 74,93 875,33 Beam web - tension - group
Ft,ep,Rd(4 + 3 + 2 + 1) - ∑31 Ftj,Rd = 271,30 - 142,75 128,54 Front plate - tension - group
Ft,wb,Rd(4 + 3 + 2 + 1) - ∑31 Ftj,Rd = 1359,12 - 142,75 1216,37 Beam web - tension - group
Additional reduction of the bolt row resistance
Ft4,Rd = Ft1,Rd h4/h1
Ft4,Rd = 7,11 [kN] Reduced bolt row resistance [6.2.7.2.(9)]
SUMMARY TABLE OF FORCES
Nr hj Ftj,Rd Ft,fc,Rd Ft,wc,Rd Ft,ep,Rd Ft,wb,Rd Ft,Rd Bp,Rd
1 469 67,82 67,82 159,54 67,82 350,32 67,82 404,62
2 329 47,58 67,82 159,54 67,82 350,32 67,82 404,62
3 189 27,34 67,82 159,54 67,82 350,32 67,82 404,62
4 49 7,11 67,82 159,54 67,82 350,32 67,82 404,62
CONNECTION RESISTANCE FOR BENDING Mj,Rd
Mj,Rd = ∑ hj Ftj,Rd
Mj,Rd = 53,00 [kN*m] Connection resistance for bending [6.2]
Mb1,Ed / Mj,Rd ≤ 1,0 0,94 < 1,00 verified (0,94)

WELD RESISTANCE
11586 [mm2] Area of all welds [4.5.3.2(2)
Aw =
]
7168 [mm2] Area of horizontal welds [4.5.3.2(2)
Awy =
]
4418 [mm2] Area of vertical welds [4.5.3.2(2)
Awz =
]
11586 [mm2] Area of all welds [4.5.3.2(2)
Aw =
]
42539156 4 Moment of inertia of the weld arrangement with respect to the hor. [4.5.3.2(5)
Iwy = 6 [mm ] axis ]
⊥max=⊥max -24,17 [MPa Normal stress in a weld [4.5.3.2(5)
= ] ]
[MPa [4.5.3.2(5)
⊥=⊥ = -21,15 Stress in a vertical weld
] ]
II = 0,00 [MPa Tangent stress [4.5.3.2(5)
] ]
[4.5.3.2(7)
w = 0,85 Correlation coefficient
]
[⊥max2 + 3*(⊥max2)] ≤ fu/(w*M2) 48,33 < 404,71 verified (0,12)
[⊥2 + 3*(⊥2+II2)] ≤ fu/(w*M2) 42,30 < 404,71 verified (0,10)
⊥ ≤ 0.9*fu/M2 24,17 < 309,60 verified (0,08)

CONNECTION STIFFNESS
twash = 4 [mm] Washer thickness [6.2.6.3.(2)]
hhead = 12 [mm] Bolt head height [6.2.6.3.(2)]
hnut = 16 [mm] Bolt nut height [6.2.6.3.(2)]
Lb = 55 [mm] Bolt length [6.2.6.3.(2)]
k10 = 5 [mm] Stiffness coefficient of bolts [6.3.2.(1)]
STIFFNESSES OF BOLT ROWS
Nr hj k3 k4 k5 keff,j keff,j hj keff,j hj2
Sum 1244 440241
1 469 2 89 70 1 564 264535
2 329 2 89 62 1 395 129906
3 189 2 89 62 1 227 42900
4 49 2 89 67 1 59 2901
keff,j = 1 / (∑35 (1 / ki,j)) [6.3.3.1.(2)]
zeq = ∑j keff,j hj2 / ∑j keff,j hj
zeq = 354 [mm] Equivalent force arm [6.3.3.1.(3)]
keq = ∑j keff,j hj / zeq
keq = 4 [mm] Equivalent stiffness coefficient of a bolt arrangement [6.3.3.1.(1)]
Avc = 3178 [mm2] Shear area EN1993-1-1:[6.2.6.(3)]
 = 1,00 Transformation parameter [5.3.(7)]
z= 354 [mm] Lever arm [6.2.5]
k1 = 3 [mm] Stiffness coefficient of the column web panel subjected to shear [6.3.2.(1)]
k2 = Stiffness coefficient of the compressed column web [6.3.2.(1)]
Sj,ini = E zeq2 / ∑i (1 / k1 + 1 / k2 + 1 / keq) [6.3.1.(4)]
Sj,ini = 44449,00 [kN*m] Initial rotational stiffness [6.3.1.(4)]
= 2,55 Stiffness coefficient of a connection [6.3.1.(6)]
Sj = Sj,ini /  [6.3.1.(4)]
Sj = 17410,84 [kN*m] Final rotational stiffness [6.3.1.(4)]
Connection classification due to stiffness.
Sj,rig = 53365,60 [kN*m] Stiffness of a rigid connection [5.2.2.5]
Sj,pin = 3335,35 [kN*m] Stiffness of a pinned connection [5.2.2.5]
Sj,pin ≤ Sj,ini < Sj,rig SEMI-RIGID

WEAKEST COMPONENT:
BOLT RUPTURE

REMARKS
Distance of bolts from an edge is too large. 127 [mm] > 120 [mm]
The thickness of bracket flange is less than the thickness of beam flange 12 [mm] < 13 [mm]
Connection conforms to the code Ratio 0,94