Technote #Cm7 Vibxpert: 2-Channel-Measurements Via Machine Protection Systems (E.G. Bently Nevada 3300 Series)

This document describes how to use a VIBXPERT device to record 2-channel vibration measurements from sensors connected to a Bently Nevada 3300 series machine protection system. The VIBXPERT is connected to the trigger output and buffered vibration signal outputs of the Bently Nevada system. User-defined voltage sensors are selected in the VIBXPERT and measurement parameters are set based on the Bently Nevada specifications. The resulting orbit measurement data can then be analyzed in OMNI-TREND software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
150 views1 page

Technote #Cm7 Vibxpert: 2-Channel-Measurements Via Machine Protection Systems (E.G. Bently Nevada 3300 Series)

This document describes how to use a VIBXPERT device to record 2-channel vibration measurements from sensors connected to a Bently Nevada 3300 series machine protection system. The VIBXPERT is connected to the trigger output and buffered vibration signal outputs of the Bently Nevada system. User-defined voltage sensors are selected in the VIBXPERT and measurement parameters are set based on the Bently Nevada specifications. The resulting orbit measurement data can then be analyzed in OMNI-TREND software.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Condition Monitoring

TechNote #CM7 VIBXPERT®


2-channel-measurements via machine protection systems
(e.g. Bently Nevada 3300 series)

Brief description
This technical note describes how VIBXPERT can
record 2-channel-measurements (e.g. relative shaft Bently Nevada
vibration (orbit), balancing in 2 planes, ...) by measur- machine protection
ing off the sensor signals on the buffered outputs of a system 3300 series
machine protection system (Bently Nevada 3300 ser.).

Measurement configuration 2 x BNC cable, 1m


VIB 344221-1
The sensors and machine protection system have
already been installed.
VIB 5.443
Connect the trigger cable (VIB 5.443) to the VIBXPERT
digital input and to the trigger signal output of the
Bently Nevada measurement amplifier (3300 series). 2x cable for low-
voltage VIB 5.433
Connect two VIBXPERT cables for low signal voltage
(VIB 5.433) to the VIBXPERT analog inputs (channel A
& B). Connect these cables with two BNC cables (VIB
344221-1) connected to the vibration signal output
of the Bently Nevada measurement amplifier (3300
VIBXPERT
series).

Measurement
Select orbit measurement, and open the sensor setup
in the task manager.
Select user-defined (voltage) sensors, and enter the
parameters for sensitivity, frequency range, and offset
taking into account the specifications of the measure-
ment amplifier.
Start the measurement.
Save the measurement and load the result in OMNI-
TREND using ‘Multimode-Import’.

The example shows a typical orbit of a gas turbine.