0% found this document useful (0 votes)
133 views3 pages

Power Swing Detection: ABB Automation Products AB

1. The document appears to be a diagram showing the connections and relationships between various components in an electrical system labeled with identification codes like ZMH1, ZDA1, PHM1, etc. 2. It includes components like lines, fuses, breakers and their connections to trip units and protection modules. 3. The diagram uses labels and lines to show the flow of electrical parameters like current, voltage and direction between the different components.

Uploaded by

naran19794735
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
133 views3 pages

Power Swing Detection: ABB Automation Products AB

1. The document appears to be a diagram showing the connections and relationships between various components in an electrical system labeled with identification codes like ZMH1, ZDA1, PHM1, etc. 2. It includes components like lines, fuses, breakers and their connections to trip units and protection modules. 3. The diagram uses labels and lines to show the flow of electrical parameters like current, voltage and direction between the different components.

Uploaded by

naran19794735
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

1 2 3 4 5 6

ZMH1-(1103,3) ZMM1-(1104,3)

ZMHPDIS_21 ZMMPDIS_21
ZDA1-(910,3)
LINE_CT_A_I3PH I3P TRIP ZMH1-TRIP LINE_CT_A_I3PH I3P
ZDARDIR

AIN\2-O LINE_CT_A_I3PH I3P STFWPE ZDA1-STFWPE LINE_VT_A_U3PH U3P TRL1 ZMH1-TRL1 LINE_VT_A_U3PH U3P

AIN\1-O LINE_VT_A_U3PH U3P STRVPE ZDA1-STRVPE ZDM-DIRCURR CURR_INP TRL2 ZMH1-TRL2 FALSE BLOCK

COMMON\2-O GRP_OFF I3PPOL ZDM-DIRVOLT VOLT_INP TRL3 ZMH1-TRL3 LINE_FUSE_FAILURE_FSD1-BLKZ BLKZ

DIREFCND ZDA1-STDIR
1-O ZDM_DIRCND DIRCND ZDM-DIRPOL POL_VOLT TRPE FALSE BLKTR

FALSE BLOCK TRPP PHM_STCNDPHS STCND

LINE_FUSE_FAILURE_FSD1-BLKZ BLKZ START ZMH1-START ZDA1-STDIR DIRCND


PHM1-(920,3)

A LINE_CT_A_I3PH I3P
FMPSPDIS
STL1 PHM_STL1
TRUE

ZSM1_HSIR
BLKZMTD

BLKHSIR
STL1

STL2
ZMH1-STL1

ZMH1-STL2
A
LINE_VT_A_U3PH U3P STL2 PHM_STL2
FALSE BLKTRIP STL3 ZMH1-STL3

LINE_FUSE_FAILURE_FSD1-BLKZ BLOCK STL3 PHM_STL3 ZMM2-(1109,3)


FALSE BLKPE STPE
ZMMAPDIS_21
ZMH3-START ZSTART STPE PHM_STPE
FALSE BLKPP STPP I3P

TRP1_TR3P TR3PH
ZDM_DIRCND DIRCND U3P
STCNDPHS PHM_STCNDPHS
FALSE 1POLEAR
PHM_STCNDPHS STCND BLOCK

PHM_STCNDPLE LDCND BLKZ


STCNDPLE PHM_STCNDPLE

BLKTR

ZMH2-(1108,3)
STCNDLE PHM_STCNDLE STCND
O011-(508,3)
ZMHPDIS_21
I3P TRIP ZMH2-TRIP DIRCND
OR

1-O ZDA1-STFWPE INPUT1 OUT START PHM-START


U3P TRL1 ZMH2-TRL1

1-O ZDA1-STRVPE INPUT2 NOUT


CURR_INP TRL2 ZMH2-TRL2

3-O ZM03_START INPUT3


VOLT_INP TRL3 ZMH2-TRL3

2-O ZSM1_BLKZMTD INPUT4


POL_VOLT TRPE
ZMM3-(1114,3)

ZMMAPDIS_21
1-O ZDM1-STFW INPUT5
BLOCK TRPP I3P

B 1-O ZDM1-STRV INPUT6


BLKZ START ZMH2-START U3P
ZDM1-(895,3)

BLKZMTD STL1 ZMH2-STL1 BLOCK


ZDMRDIR
LINE_CT_A_I3PH I3P DIR_CURR ZDM-DIRCURR
BLKHSIR STL2 ZMH2-STL2 BLKZ

B
LINE_VT_A_U3PH U3P
DIR_VOLT ZDM-DIRVOLT BLKTRIP STL3 ZMH2-STL3 BLKTR

BLKPE STPE STCND

DIR_POL ZDM-DIRPOL BLKPP STPP DIRCND

DIRCND

STFW ZDM1-STFW STCND

STRV ZDM1-STRV LDCND

STDIRCND ZDM_DIRCND

ZMH3-(1113,3)

ZMHPDIS_21
I3P TRIP ZMH3-TRIP

U3P TRL1 ZMH3-TRL1

CURR_INP TRL2 ZMH3-TRL2

VOLT_INP TRL3 ZMH3-TRL3

POL_VOLT TRPE

POWER SWING DETECTION BLOCK

BLKZ
TRPP

START ZMH3-START

BLKZMTD STL1 ZMH3-STL1

PSD1-(1055,3)
BLKHSIR STL2 ZMH3-STL2
ZMRPSB_78

AIN\2-O LINE_CT_A_I3PH I3P START PSD1_START BLKTRIP STL3 ZMH3-STL3

AIN\1-O LINE_VT_A_U3PH U3P ZOUT PSD1_ZOUT BLKPE STPE

C
FALSE BLOCK ZIN PSD1_ZIN BLKPP STPP

FALSE BLKI01 DIRCND

C FALSE

FALSE
BLKI02

BLK1PH
STCND

LDCND

FALSE REL1PH

FALSE BLK2PH

TRUE REL2PH

FALSE I0CHECK

FALSE TRSP

FALSE EXTERNAL

SWITCH ON TO FAULT LOGIC


SFV1-(2400,3)

ZCVPSOF
LINE_CT_A_I3PH I3P TRIP SOTF_TRIP

LINE_VT_A_U3PH U3P

O002-(205,3)
FALSE BLOCK ZM02_START
OR
I001-(201,3)
BIO\1-O SOTF_INIT INPUT1 OUT BC ZM03_START
INV
FALSE INPUT2 NOUT ZM03_START ZACC CB_CLOSED INPUT OUT CB_OPEN AR01-START

FALSE INPUT3

D
FALSE INPUT4

FALSE

FALSE
INPUT5

INPUT6
D
Prepared
Approved DIST_PRO
Resp dep Rev Ind
Rev Ind Reg nr Sheet 1/3
Based on Pcl ABB Automation Products AB
1 2 3 4 5 6
1 2 3 4 5 6
ZMM1-(1104,3)

O012-(510,3)
ZMMPDIS_21
I3P TRIP ZMM1-TRIP O034-(2005,3)
OR
ZMM1-TRIP INPUT1 OUT ZM01_TRIP
OR
U3P TRL1 ZMM1-TRL1
ZMM2-TRIP INPUT1 OUT
ZMH1-TRIP INPUT2 NOUT
BLOCK TRL2 ZMM1-TRL2
ZMH2-TRIP INPUT2 NOUT
FALSE INPUT3
BLKZ TRL3 ZMM1-TRL3
FALSE INPUT3
FALSE INPUT4
BLKTR START ZMM1-START
FALSE INPUT4
FALSE INPUT5
STCND STL1 ZMM1-STL1
FALSE INPUT5
FALSE INPUT6
DIRCND STL2 ZMM1-STL2
FALSE INPUT6

A STL3

STND
ZMM1-STL3

O013-(704,3) A
O035-(2007,3)
OR
ZMM1-TRL1 INPUT1 OUT ZM01_TRL1
OR
ZMM2-(1109,3) ZMM2-TRL1 INPUT1 OUT
ZMH1-TRL1 INPUT2 NOUT
ZMMAPDIS_21
ZMH2-TRL1 INPUT2 NOUT
I3P TRIP ZMM2-TRIP FALSE INPUT3

FALSE INPUT3
U3P TRL1 ZMM2-TRL1 FALSE INPUT4

FALSE INPUT4
BLOCK TRL2 ZMM2-TRL2 FALSE INPUT5

FALSE INPUT5
BLKZ TRL3 ZMM2-TRL3 FALSE INPUT6

FALSE INPUT6
BLKTR START ZMM2-START

O014-(706,3)
STCND STL1 ZMM2-STL1
O036-(2009,3)
OR
DIRCND STL2 ZMM2-STL2 ZMM1-TRL2 INPUT1 OUT ZM01_TRL2
OR
ZMM2-TRL2 INPUT1 OUT
STL3 ZMM2-STL3 ZMH1-TRL2 INPUT2 NOUT

ZMH2-TRL2 INPUT2 NOUT


STND FALSE INPUT3

FALSE INPUT3
FALSE INPUT4

ZMM3-(1114,3) FALSE INPUT4


FALSE INPUT5
ZMMAPDIS_21
FALSE INPUT5
I3P TRIP ZMM3-TRIP FALSE INPUT6

B
FALSE INPUT6
U3P TRL1 ZMM3-TRL1

O015-(708,3)
BLOCK TRL2 ZMM3-TRL2
O037-(2103,3)
OR
BLKZ TRL3 ZMM3-TRL3 ZMM1-TRL3 INPUT1 OUT ZM01_TRL3
OR

B
ZMM2-TRL3 INPUT1 OUT
BLKTR START ZMM3-START ZMH1-TRL3 INPUT2 NOUT

ZMH2-TRL3 INPUT2 NOUT


STCND STL1 ZMM3-STL1 FALSE INPUT3

FALSE INPUT3
DIRCND STL2 ZMM3-STL2 FALSE INPUT4

FALSE INPUT4
STL3 ZMM3-STL3 FALSE INPUT5

FALSE INPUT5
STND FALSE INPUT6

FALSE INPUT6

O023-(1008,3)

O038-(2105,3)
OR
ZMM1-START INPUT1 OUT ZM01_START
OR
ZMM2-START INPUT1 OUT
ZMH1-START INPUT2 NOUT

ZMH2-START INPUT2 NOUT


FALSE INPUT3

FALSE INPUT3
FALSE INPUT4

FALSE INPUT4
FALSE INPUT5

FALSE INPUT5
FALSE INPUT6

FALSE INPUT6

O024-(1010,3)

O039-(2107,3)
OR
ZMM1-STL1 INPUT1 OUT ZM01_STL1
OR
ZMM2-STL1 INPUT1 OUT
ZMH1-STL1 INPUT2 NOUT

ZMH2-STL1 INPUT2 NOUT


FALSE INPUT3

FALSE INPUT3
FALSE INPUT4

C
FALSE INPUT4
FALSE INPUT5

FALSE INPUT5
FALSE INPUT6

C O032-(1610,3)
FALSE INPUT6

O040-(2109,3)
OR
ZMM1-STL2 INPUT1 OUT ZM01_STL2
OR
ZMM2-STL2 INPUT1 OUT
ZMH1-STL2 INPUT2 NOUT

ZMH2-STL2 INPUT2 NOUT


FALSE INPUT3

FALSE INPUT3
FALSE INPUT4

FALSE INPUT4
FALSE INPUT5

FALSE INPUT5
FALSE INPUT6

FALSE INPUT6

FAULT LOCATOR O033-(2003,3)

OR
O041-(2504,3)

FLO1-(3400,3) ZMM1-STL3 INPUT1 OUT ZM01_STL3


OR
ZMM2-STL3 INPUT1 OUT
LMBRFLO
ZMH1-STL3 INPUT2 NOUT
PHM_STL1 PHSELL1 FLTDISTX FLTDISTX
ZMH2-STL3 INPUT2 NOUT
FALSE INPUT3
PHM_STL2 PHSELL2 CALCMADE
FALSE INPUT3
O004-(209,3) FALSE INPUT4
PHM_STL3 PHSELL3 BCD_80
ZSM1-(950,3) FALSE INPUT4
OR
FALSE INPUT5
3-OZM02_START INPUT1 OUT CALCDIST BCD_40
ZSMGAPC
FALSE INPUT5
LINE_CT_A_I3PH I3P BLKZMTD ZSM1_BLKZMTD FALSE INPUT6
3-OZM03_START INPUT2 NOUT BCD_20
FALSE INPUT6
LINE_VT_A_U3PH U3P BLKCHST ZSM1_CHST
CB_AR\2-OAR01-START INPUT3 BCD_10

FALSE BLOCK CHSTOP ZSM1_CHSTOP


FALSE INPUT4 BCD_8

FALSE REVSTART HSIR ZSM1_HSIR

D
FALSE INPUT5 BCD_4

D
FALSE BLOCKCS
FALSE INPUT6 BCD_2

FALSE CBOPEN
BCD_1

Prepared
Approved DIST_PRO
Resp dep Rev Ind
Rev Ind Reg nr Sheet 2/3
Based on Pcl ABB Automation Products AB
1 2 3 4 5 6
1 2 3 4 5 6
O034-(2005,3)

O042-(2506,3)

OUT ZM02_TRIP
OR
ZMM3-TRIP INPUT1 OUT ZM03_TRIP
NOUT

ZMH3-TRIP INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4

FALSE INPUT5

A FALSE INPUT6

A
O035-(2007,3)

O043-(2508,3)

OUT ZM02_TRL1
OR
ZMM3-TRL1 INPUT1 OUT ZM03_TRL1
NOUT

ZMH3-TRL1 INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4

FALSE INPUT5

FALSE INPUT6

O036-(2009,3)

O044-(2510,3)

OUT ZM02_TRL2
OR
ZMM3-TRL2 INPUT1 OUT ZM03_TRL2
NOUT

ZMH3-TRL2 INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4

FALSE INPUT5

B FALSE INPUT6

O037-(2103,3)

O045-(2604,3)

B
OUT ZM02_TRL3
OR
ZMM3-TRL3 INPUT1 OUT ZM03_TRL3
NOUT

ZMH3-TRL3 INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4

FALSE INPUT5

FALSE INPUT6

O038-(2105,3)

O046-(2606,3)

OUT ZM02_START
OR
ZMM3-START INPUT1 OUT ZM03_START
NOUT

ZMH3-START INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4

FALSE INPUT5

FALSE INPUT6

O039-(2107,3)

O047-(2608,3)

OUT ZM02_STL1
OR
ZMM3-STL1 INPUT1 OUT ZM03_STL1
NOUT

ZMH3-STL1 INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4 C
C
FALSE INPUT5

FALSE INPUT6

O040-(2109,3)

O048-(2610,3)

OUT ZM02_STL2
OR
ZMM3-STL2 INPUT1 OUT ZM03_STL2
NOUT

ZMH3-STL2 INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4

FALSE INPUT5

FALSE INPUT6

O041-(2504,3)

O049-(2904,3)

OUT ZM02_STL3
OR
ZMM3-STL3 INPUT1 OUT ZM03_STL3
NOUT

ZMH3-STL3 INPUT2 NOUT

FALSE INPUT3

FALSE INPUT4

FALSE INPUT5

FALSE INPUT6

D D
Prepared
Approved DIST_PRO
Resp dep Rev Ind
Rev Ind Reg nr Sheet 3/3
Based on Pcl ABB Automation Products AB
1 2 3 4 5 6

You might also like