The document describes an iPASOLINK 400 Clock Module. It is an option module that mounts on an MC-A4 Main Board and is required for network synchronization in various configurations including SNCP E1 Ring, channelized STM-1, Sync E, and IEEE 1588v2 (slave). It provides external clock input/output and references frequencies of 2 MHz, 5 MHz, and 10 MHz.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
154 views19 pages

iPASOLINK 400 Clock Module

The document describes an iPASOLINK 400 Clock Module. It is an option module that mounts on an MC-A4 Main Board and is required for network synchronization in various configurations including SNCP E1 Ring, channelized STM-1, Sync E, and IEEE 1588v2 (slave). It provides external clock input/output and references frequencies of 2 MHz, 5 MHz, and 10 MHz.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 19

iPASOLINK 400 Clock Module

Clock Module
CLK2M-C

Option module for Clock Sync and mounted on MC-A4 Main Board.

Required for all stations for Network Sync


1. SNCP E1 Ring Configuration
2. Channelized STM-1 (Not required for STM-1 SPI Mode operation)
3. Sync Ether
4. External CLK In/Out
5. IEEE 1588v2(slave)

*1 Not required for HOP Topology, TREE Topology, for the case Network Sync is not in use in Back-Back
Connection.
*2 SNCP E1 Ring Topology, Channelized STM-1,Sync E and IEEE1588v2 Software key is separately required.

iPASOLINK Introduction 56
iPASOLINK 100E/200 / 400/1000 Modem
Power ON/OFF Switch
Ground
iPASOLINK-200 iPASOLINK-400/1000

Alarm ( Red )

Power ON (Green)

ONLINE (Green)

IF IN / OUT TX STATUS (Green)


TX frequency: 350 MHz RX STATUS (Green)
XIF IN/ OUT
RX frequency 140 MHz
Frequency: 140 MHz
Ref Frequency: 5 MHz (XPIC)
REF FREQ: 5 MHz
DC Power : -48V
Connector: IEC 169-29(1.0/2.3)
Connector: TNC (Female)
Impedance: 75 Ohms
Control 10 MHz
FOR XPIC BETWEEN MASTER
Impedance: 50 Ohms AND SUB MASTER

iPASOLINK-100E

Alarm ( Red )

Maintenance
( Orange)

iPASOLINK Introduction 57
iPASOLINK 200 / 400/1000 IDU – STM-1 Card

iPASOLINK 200 iPASOLINK 400/400A/1000

iPASOLINK 200 / 400/400A//1000 iPASOLINK 200 / 400/400A/1000

STM-1 INTFC (ELECTRICAL) -SPECIFICATIONS STM-1 INTFC (OPTICAL) -SPECIFICATIONS


TYPE ITU-T G.703 TYPE ITU-T G957
BITRATE 155.520 Mbps BITRATE 155.520 Mbps
LEVEL 1 Vp_p L-1.1: 0 TO -8 (TX) / -10 TO -34 dBm (RX)
LEVEL
CODE CMI S-1.1: -8 TO -15dBm (TX) / -8 TO -28 dBm (RX)
CODE NRZ
CONNECTOR IEC 169-29 (1.0/2.3)
WAVELENGTH 1310 NM
IMPEDANCE 75 Ohms (Unbalanced)
CONNECTOR LC

Transport modes of STM-1.


Through (SPI) Mode iPASOLINK
iPASOLINK 400/400A/1000
400/400A/1000
Port1
STM1 STM1 iPASO 400 Automatic Protection Switching SFP combination
No Port 1 Port 2
APS Grp-1 APS Grp1 APS Grp2
1 S-1.1 -
Same slot Different slot
2 L-1.1 -
Channelized Mode Port 1 Port2 Slot1 Slot2 Slot1 Slot2
3 ELE -
Port1 port1 port2 port2
Port1 4 S-1.1 S-1.1
STM1 --- 63 E1
5 L-1.1 L-1.1
-
6 ELE ELE

iPASOLINK Introduction 58
2 x STM-1 universal card (STM1-A)

Transport modes of STM-1.

Online Status (Green) Online Status (Green) Alarm ( Red )


Through (SPI) Mode Transparent mode of STM-1. No processing in IDU.
Port1 -2 STM-1 can be handled by single module Online LED indicates the ONLINE
STM1 STM1
STM-1 in APS operation
STM1 STM1
Port2

Through (SPI) Mode with APS SPI mode with line redundancy (APS).
The following Software Key is required
Port1 -STM-1 APS Protection Key
STM1 STM1
STM1
Port2
Terminating MST / RST of STM-1 and drop insert in VC-12 (E1)level
Port1should be source port
Channelized Mode CLK2M-C module is required
Port1 The following Software Key is required
STM1
- STM-1 MUX/DEMUX Key
- 63 E1
---
Port2

Channelized Mode with APS Channelized-STM-1 mode with line redundancy (APS)
CLK2M-C module is required
Port1
STM1 The following Software Key is required
-STM-1 MUX/DEMUX Key
STM1 --- 63 E1
-STM-1 APS Protection Key
Port2 -

iPASOLINK Introduction 59
iPASOLINK 400/1000 Main Board
2M IN /OUT
Input / Output signal 16 x E1
Bit Rate 2.048Mpps +/_ 50ppm
Interface HDB3 (ITU-T G.703)
Impedance 75 Ohms, Unbalance
(S/W Selectable) 120 Ohms Balance
Connector MDR-68 pins

400

1000

LAN Interface (Electrical) Port 1,2 Gigabit Ether Interface (Optical) 3,4
Input / Output signal 10/100Base-T(X) or 10/100/1000 BASE-T Input / Output signal 1000 BASE-SX / 1000 BASE - LX
Speed & Duplex 10/100 Base-T(X) / 1000 Base-T Auto Speed & Duplex 1000 Mbits Full Duplex Auto
Sensing or Fixed Negotiation fixed
Flow Control ON or OFF (Selectable) Flow Control ON or OFF (Selectable)
Link Loss Forwarding Disable/Enable (Selectable) Link Loss Forwarding Disable/Enable (Selectable)
Connector RJ-45 Connector SFP Optical Interface (LC)

Port 1 can be selected as user port1 or Management port NE SFP opticalS-1.1/L1.1


Electrical (RJ-45)*
Software key Required to activate ports 3, 4

iPASOLINK Introduction 60
iPASOLINK 400/1000 GbE Universal Slot Interface
Port2 (Green) Port4(Green)
LAN Link Status LAN Link Status
Blink when data TX Blink when data TX

Por1 (Green)
LAN Interface (Electrical) Port 1,2 LAN Link Status
Blink when data TX
Input / Output signal 10/100Base-T(X)/ 1000 BASE-T Alarm (Red)
Speed & Duplex 10/100 Base-T(X) / 1000 Base-T Alarm Status
Port 3(Green)
Auto Sensing or Fixed
LAN Link Status
Flow Control ON or OFF (Selectable) Blink when data TX

Link Loss Forwarding Disable/Enable (Selectable)


Connector RJ-45

Ethernet Features
VLAN Port Based VLAN/ Tag Based VLAN / Q –in Q
Gigabit Ether Interface (Optical) 3,4
QoS 802.1p CoS / ToS/Diffserv/MPLS EXP
Input / Output signal 1000 BASE-SX / 1000 BASE -
QoS Control 4SP, 1xSP+3xDWRR, 4xDWRR, 1xSP+7DWRR,
LX
2xSP+6DWRR
Speed & Duplex 1000 Mbits Full Duplex Auto
Bandwidth Port and class shaper, policing per VLAN or port Negotiation fixed
Management
Flow Control ON or OFF (Selectable)
Jumbo frame Up to 2000 bytes
Link Loss Forwarding Disable/Enable (Selectable)
Protection RSTP (802.1w, ERP (ITU-T G.8032)* LACP
(802.3ad)* Connector SFP Optical Interface (LC)
Note *-late release

iPASOLINK Introduction 61
AUX Card – AUX-A
Optional auxiliary Module support ALM / EOW / NE2

The following Interface is available


・HK ALM IN/OUT
・additional four parallel alarm outputs
・EOW B-B connection 2 Port
・NE2 : DCN RS-485 (Async.) Back-to-back connection

Summary of the auxiliary interface ports.


iPASO400 iPaso1000 iPASO1000 iPASO 400/1000
MC-A4 MC-M
Interface TERM-M AUX-A (Option) Note
(main card) (main card)
IN - - - 6 (ALM I/P),4 (CLS in)
HK ALM
OUT 2 (ALM) 2 (ALM) - 4 (HK CTRL),4CLS(out)
Jack 1 1 - -
BZ 1 1 - -
OW
Call SW 1 1 - -
EXT IN/OUT - - - 2 For Back-to-Back connection
V.11 2 1 1 - Sync / Async
DSC
RS-232C 2 1 1 - Async
LCT 1 1 - - 10/100BASE-T(X)
NMS 1 - 1 - 10/100BASE-T(X)
DCN
NE 1 - 1 - 10/100BASE-T(X)
NE2 - - - 1 9.6kbps Async (RS-485)DCN port
USB MEM slot 1 1 - - For F/W download, etc.
2MHz / bps *Optional clock
EXT CLK IN / OUT (1)* 1 - -
(CLK2M-C) module is required.

iPASOLINK Introduction 62
iPASOLINK Transmission Capacity

ITEM IDU
Channel
7 MHZ 14MHz 28MHz 40MHz 56 MHz
Spacing
Radio Max Packet Radio Max Packet Radio Max Packet Radio Max Packet Radio Max Packet
Capacity Throughput Capacity Throughput Capacity Throughput Capacity Throughput Capacity Throughput
QPSK 10 13 22 27 45 57 56 78 91 113
iPASOLINK
100E
Transmission 16 QAM 22 26 45 55 91 113 113 156 183 227
Capacity
100/200 32 QAM 27 33 56 69 113 141 141 196 228 284
and
Channel 64 QAM 33 40 67 83 136 170 170 235 274 341
spacing 128 QAM 39 47 79 96 159 198 198 274 320 398
256 QAM 45 53 90 111 182 227 226 314 366 456

iPASOLINK 512QAM 60 124 204 254 254 351 410 510


400/400A 1024QAM 67 137 228 279 283 386 458 559
1000 2048QAM 152 250 309 311 428 504 620

* Max Packet Throughput using 64 byte packet size

iPASOLINK Introduction 63
PERFORMANCE – iPASOLINK 200 IDU
ITEM IDU

E1 16xE1 (G703) MDR 68 connector in main board (32 E1 with additional 16 E1 optional card)
2 x 10/100 Base-T(X) RJ-45 connector (up to 4 x 10/100/1000 Base –T available with software upgrade)
Main Signal Interface LAN
2 x 1000 SX or LX with SFP modules (connector type LC)
STM-1 1 x STM-1 (S 1.1 or L 1.1 ) option card with software selectable channelized STM-1 (connector type – LC)
Connector Type : TNC female
Inter facility Link (IDU-ODU)
Cable length : Nominal 300m maximum with 8D-FB-E or equivalent performance cable
FUNCTION OUTLINE
Native IP and Native TDM Modem has dual native (native IP and native TDM) signal processing circuit
Adaptive Modulation Radio (AMR) QPSK / 16 QAM/ 32 QAM / 64 QAM / 128 QAM / 256 QAM (6 modulation schemes changing adaptively)
Radio (1+1) Hot standby / Space diversity , (1+1) twin Path (Frequency Diversity)
Protection E1 Ring E1 SNCP (sub network connection protection ) support
LAN Ring RSTP/MSTP and Eth Ring Protection support
XPIC (CCDP) Function QPSK to 256 QAM modulation at (14 MHz/28MHz/56MHz),
AMR (1+1) and XPIC combination AMR and (1+1), AMR and XPIC combination available
DXC (E1 Cross Connect) Capacity Up to 168 x 168 E1 non blocking
Synchronization TDM, Sync ETH
2.048 MHz or 2.048 Mbps external clock input / output, 75 or 120 Ohms selectable, D-Sub 44 pin
External Clock Interface
connector

iPASOLINK Introduction 64
PERFORMANCE-IHG ODU
ITEM 6 7-8 10-11 13 15 18 23 26 28 32 38 42 Frequency in GHz
Transmit Power - Measured at ODU TX port
QPSK 29 29 25 25 25 24 24 23 22 22 20 20
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
QPSK ( 56 MHz) -84.5 -84.5 -84.0 -83.5 -83.5 -83 -83.5 -82.5 -82.5 -82.5 -81.5 -79.5
QPSK ( 28 MHz) -87.5 -87.5 -87 -86.5 -86.5 -86 -86.5 -85.5 -85.5 -85.5 -84.5 -82.5 Guaranteed TX Power
QPSK ( 14 MHz) -90.5 -90.5 -90 -89.5 -89.5 -89 -89.5 -88.5 -88.5 -88.5 -87.5 -85.5 6-28 GHz +/- 1.5dB
QPSK ( 7 MHz) -93.5 -93.5 -93 -92.5 -92.5 -92 -92.5 -91.5 -91.5 -91.5 -90.5 -88.5 32-38 GHz +/-2.5 dB
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
QPSK ( 56 MHz) 113.5 113.5 109 108.5 108.5 107 107.5 105.5 104.5 104.5 101 99.5
QPSK ( 28 MHz) 116.5 116.5 112 111.5 111.5 110 110.5 108.5 107.5 107.5 104.5 102.5
Guaranteed Threshold
QPSK ( 14 MHz) 119.5 119.5 115 114.5 114.5 113 113.5 111.5 110.5 110.5 107.5 105.5
Rx Threshold at 10-6 BER
QPSK ( 7 MHz) 122.5 122.5 118 117.5 117.5 116 116.5 114.5 113.5 113.5 110.5 108.5
Max input level - 20 dBm for BER less than 10-3 6-38 GHz +3 dB

Transmit Power - Measured at ODU TX port


16 QAM 26 26 22 22 22 21 21 19 18 18 17 16 56 MHz
16 QAM 27 27 23 23 23 22 22 20 19 19 18 17 7MHz/ 14 MHz / 28 MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
16 QAM ( 56 MHz) -78 -78 -77.5 -77 -77 -76.5 -77 -76 -76 -76 -75 -73

16 QAM( 28 MHz) -81 -81 -80.5 -80 -80 -79.5 -80 -79 -79 -79 -78 -76
16 QAM ( 14 MHz) -84 -84 -83.5 -83 -83 -82.5 -83 -82 -82 -82 -81 -79
16 QAM ( 7 MHz) -87 -87 -86.5 -86 -86 -85.5 -86 -85 -85 -85 -84 -82
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
16 QAM ( 56 MHz) 104 104 99.5 99 99 97.5 98 95 94 94 92 89
16 QAM( 28 MHz) 108 108 103.5 106 106 104.5 105 102 101 101 99 93
16 QAM ( 14 MHz) 111 111 106.5 106 106 104.5 105 102 101 101 99 96
Guaranteed System Gain
16 QAM ( 7 MHz) 114 114 109.5 109 109 107.5 108 105 104 104 102 99
6-28 GHz -3 dB
Max input level - 20 dBm for BER less than 10-3
32-38 GHz -4 dB

iPASOLINK Introduction 65
PERFORMANCE-IHG ODU
ITEM 6 7-8 10-11 13 15 18 23 26 28 32 38 42 Frequency in GHz
Transmit Power - Measured at ODU TX port
32 QAM 25 25 21 21 21 20 18 18 18 18 17 16 56 MHz
7MHz/ 14 MHz / 28
32 QAM 26 26 22 22 22 21 19 19 19 19 18 16
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
32 QAM ( 56 MHz) -75 -75 -74.5 -74 -74 -73.5 74 -73 -73 -73 -72 -70
32 QAM( 28 MHz) -78 -78 -77.5 -77 -77 -76.5 -77 -76 -76 -76 -75 -73
32 QAM ( 14 MHz) -81 -81 -80.5 -80 -80 -79.5 -80 -79 -79 -79 -78 -76
32 QAM ( 7 MHz) -84 -84 -83.5 -83 -83 -82.5 -83 -82 -82 -82 -81 -79
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
32 QAM ( 56 MHz) 100 100 95.5 95 95 93.5 92 91 91 91 89 86
32 QAM( 28 MHz) 104 104 99.5 99 99 97.5 96 95 95 95 93 89
32 QAM ( 14 MHz) 107 107 102.5 102 102 100.5 99 98 98 98 96 92
32 QAM ( 7 MHz) 110 110 105.5 105 105 103.5 102 101 101 101 99 95
Transmit Power - Measured at ODU TX port

64 QAM 25 25 21 21 21 20 18 18 18 18 17 15 56 MHz
7MHz/ 14 MHz / 28
64 QAM 26 26 22 22 22 21 19 19 19 19 18 16
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
64QAM ( 56 MHz) -72 -72 -71.5 -71 -71 -70.5 -71 -70 -70 -70 -69 -67

64 QAM( 28 MHz) -75 -75 -74.5 -74 -74 -73.5 -74 -73 -73 -73 -72 -70
64 QAM ( 14 MHz) -78 -78 -77.5 -77 -77 -76.5 -77 -76 -76 -76 -75 -73
64 QAM ( 7 MHz) -81 -81 -80.5 -80 -80 -79.5 -80 -79 -79 -79 -78 -76
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
64 QAM ( 56 MHz) 97 97 92.5 91 91.5 90.5 88.5 88 88 86.5 85.5 82
64 QAM( 28 MHz) 101 101 96.5 96 96 94.5 93 92 92 92 90 86
64 QAM ( 14 MHz) 104 104 99.5 99 99 97.5 96 95 95 95 93 89
64 QAM ( 7 MHz) 107 107 102.5 102 102 100.5 99 98 98 98 96 92
Power Control 0 to 23 dB (1 dB step) + (5 dB additional ATT) 0 to 23 dB

iPASOLINK Introduction 66
PERFORMANCE-IHG ODU
ITEM 6 7-8 10-11 13 15 18 23 26 28 32 38 42 Frequency in GHz
Transmit Power - Measured at ODU TX port
128 QAM 25 25 21 21 21 20 18 18 18 18 17 15 56 MHz
7MHz/ 14 MHz / 28
128 QAM 26 26 22 22 22 21 19 19 19 19 18 16
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
128 QAM ( 56 MHz) -69 -69 -68.5 -68 -68 -67.5 -68 -67 -67 -67 -66 -64
128 QAM( 28 MHz) -72 -72 -71.5 -71 -71 -70.5 -70.5 -71 -70 -70 -69 -67
128 QAM ( 14 MHz) -75 -75 -74.5 -74 -74 -73.5 -74 -73 -73 -73 -72 -70
128 QAM ( 7 MHz) -77.5 -77.5 -77 -76.5 -76.5 -76 -76.5 -75.5 -75.5 -75.5 -74.5 -
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
128 QAM ( 56 MHz) 94 94 89.5 89 89 87.5 86 85 85 85 83 79
128 QAM( 28 MHz) 98 98 93.5 93 93 91.5 90 89 89 89 87 83
128 QAM ( 14 MHz) 101 101 96.5 96 96 94.5 93 92 92 92 90 86
128 QAM ( 7 MHz) 103 103 98 98 98.5 97.5 95.5 95 95 93.5 92.5 -
Power Control 0 to 23 dB (1 dB step) + (5 dB additional ATT) 0 to 23 dB
Transmit Power - Measured at ODU TX port

24 24 20 20 20 19 17 17 17 17 16 14 56 MHz
7MHz/ 14 MHz / 28
25 25 21 21 21 20 18 18 18 18 17 15
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
256QAM ( 56 MHz) -65.5 -65.5 -65 -64.5 -64.5 -64 -64.5 -63.5 -63.5 -63.5 -62.5 -60.5

256 QAM( 28 MHz) -68.5 -68.5 -68 -67.5 -67.5 -67 -67.5 -66.5 -66.5 -66.5 -65.5 -63.5
256 QAM( 14 MHz) -71 -71 -70.5 -70 -70 -69.5 -70 -69 -69 -69 -68 -
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
256QAM ( 56 MHz) 89.5 89.5 85 84.5 84.5 83 81.5 80.5 80.5 80.5 78.5 74.5
256 QAM( 28 MHz) 93.5 93.5 89 88.5 88.5 87 85.5 84.5 84.5 84.5 82.5 78.5
256 QAM( 14 MHz) 96 96 91.5 91 91 89.5 88 87 87 87 85 -
Power Control 0 to 23 dB (1 dB step) + (5 dB additional ATT) 0 to 23 dB

iPASOLINK Introduction 67
PERFORMANCE-IHG ODU
ITEM 6 7-8 10-11 13 15 18 23 26 28 32 38 42 Frequency in GHz
Transmit Power - Measured at ODU TX port
512 QAM 22 22 18 18 18 17 15 15 15 15 14 12 56 MHz
7MHz/ 14 MHz / 28
512 QAM 23 23 19 19 19 18 16 16 16 16 15 13
MHz
Receiver Threshold Measured at ODU RX port (dBm) at 10-6 BER [BER at 10-3 value below -1.5 dB]
512 QAM ( 56 MHz) -63.5 -63.5 -63 -62.5 -62.5 -62 -62.5 -61.5 -61.5 -61.5 -60.5 -58.5
512 QAM( 28 MHz) -66 -66 -65.5 -65 -65 64.5 -65 -64 -64 -64 -63 -61
512 QAM ( 14 MHz)
512 QAM ( 7 MHz)
System Gain Measured at ODU RX port at 10-6 BER [BER at 10-3 value below +1.5 dB]
512 QAM ( 56 MHz) 85.5 85.5 81 80.5 80.5 79 77.5 76.5 76.5 76.5 74.5 70.5
512 QAM( 28 MHz) 89 89 84.5 84 84 82.5 81 80 80 80 78 74
512 QAM ( 14 MHz)
512 QAM ( 7 MHz)
Power Control 0 to 23 dB (1 dB step) + (5 dB additional ATT) 0 to 23 dB

iPASOLINK Introduction 68
iPASOLINK
OUT DOOR UNIT

iPASOLINK Introduction 69
UP CONV RF AMP

LO
TX RF
BPF
MPX
DOWN CONV

RX RF
LNA BPF

CONTROL

DC-DC CONV

iPASOLINK Introduction
HANDLE

RF IN/OUT COAXIAL TYPE (6-8 GHz)

Label

RX LEV MONITOR
IF IN/OUT

Turn OFF the DC


power before removing
the IF cable
Frame Ground RF IN/OUT WG TYPE (6-8 GHz)

iPASOLINK Introduction

HANDLE

RF IN/OUT 13 – 38 GHz

TRP-15G 1D (IHG)

Frame Ground

IF IN/OUT
Turn OFF the DC
power before removing
the IF cable

RX LEV MONITOR

iPASOLINK Introduction 72
Frame Ground

Turn OFF the DC


power before removing
the IF cable
RX LEV MONITOR

IF IN/OUT

Frame Ground IAG can be used for up to 2048 QAM

iPASOLINK Introduction
ODU Compatibility

iPASOLINK 100E

iPASOLINK 400
NHG2 (Existing only)

iPASOLINK 200

IHG
(Supplied with iPaso)

iPASOLINK 1000
iPASOLINK Introduction