Fire Fighting System

fire fighting system

Uploaded by

Irshad Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
326 views8 pages

Fire Fighting System

fire fighting system

Uploaded by

Irshad Khan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
You are on page 1/ 8
PCIBMEMDDSISECVLS.21 a. | 2 ¥mm] | PROJECTS & DEVELOPMENT INDIA LIMITED Document No Rov | Talcher [DIL | TE Fertilizers} SECTION : VI - 3.2.1 FIRE FIGHTING SYSTEM PLANT _ : ELECTRICAL DISTRIBUTION SYSTEM PROJECT: INTEGRATED COAL BASED FERTILISER COMPLEX, AT TALCHER, ANGUL DISTRICT, ODISHA (INDIA) ° | 260321 25.08.23 Issued for Enquiry aks AMAR, AMAR nev |_REVOATE EFF DATE PURPOSE PREPD REWWO ‘PPD FORM No: 02-0000-0021F1 REVS Al rights reserved ELECTRICAL DISTRIBUTION SYSTEM | “roreaemmnaseanaa1 | TALCHER FERTILIZERS LIMTED tie Document No. | Rev FIRE FIGHTING SYSTEM ss Fertlzers | ‘TABLE OF CONTENTS NUMBER DESCRIPTION SHEET NUMBER 35 : 13.0 Safety Items. 7 Manual Call Points augue DescrIron nayaet oF FORM NO, 02.0000.0021 FS REVS Al igh reserves ge ara PDIL ELECTRICAL DISTRIBUTION SYSTEM | powsseamascomaz [0 ‘TALGHER FERTILIZERS LIMITED tilther Document No. | Rev FIRE FIGHTING SYSTEM [sheet ore | Fettilzers_ | Shi 10 2.0 3.0 34 32 33 34 35 36 a7 3.8 FORM NO, 02.0000.0021 FS REVS PURPOSE The purpose of this document is to establish the design basis of the complete fire fighting system. DEFINITIONS PESO - Petroleum And Explosives Safety Organization CCE- Chief Controller of Explosives NFPA- National Fire Protection Association IS- Indian Standards NBC- National Building Code (India) TAC — Tariff Advisory Committee SCOPE This specification covers design basis and execution requirements for fire protection system to be provided by CONTRACTOR as per statutory regulations and NFPA codes. The design and construction of the fire detection and protection equipment shall be of internationally accepted standards and in compliance with the regulations of the Tariff ‘Advisory Committee (TAC), National Building Code (NBC) - 2016 and other relevant statutory requirements for Electrical Distribution System. Any other Standard which are not mentioned in the technical specification but are found necessary to meet the requirement of TAC and standard engineering practices for safe and sound operation of the System are to be included at no extra cost to the Owner. ‘A comprehensive fire protection system shall be designed for the whole of the proposed Electrical Distribution System to provide @ high degree of protection for plant, tanks, equipment and buildings and employees. Interfacing with other systems (e.g. fuel and air handling plants, ventilation systems, etc.) will be required ‘Taping/s with the fire water mains shall be provided at plant battery limit (adjacent to the proposed plant location) as per requirement. The same (tie-in location/s) shall be decided during the detail engineering ‘The CONTRACTOR'S design and engineering activities listed in this specification are the minimum requirements to be complied with preparation of detailed design basis, specifications, standards and list of codes for each system based on guidelines given in subsequent clauses of scope of work. ‘The term ‘Fire Fighting System’ referred here generally covers various equipments and facilities being provided for controlling fires. These include faciities such as fire water network accessories and fire water piping network together with hydrants, monitors, various kinds of portable fire extinguishers like Dry Chemical Powder type, etc., as well as sand and water buckets and sign boards. The Fire Fighting System shall be designed to provide adequate facilities for extinguishing any fire in the entire area of Electrical Distribution System and associated facilities of the proposed Scope of work. The system shall be designed and installed as per TAC / NFPA API/ ISIPESO/NBC standards and also as per latest applicable standards/ codes. The rights reserved ELECTRICAL DISTRIBUTION SYSTEM PCTRSEMDOESECVIOZA TALCHER FERTRIZERS UMTED ae PDIL) | FIRE FIGHTING SYSTEM Siesta af Fertilizers | system shall be complete in all respects essential for proper installation operation and maintenance, irrespective of whether such systems are specifically mentioned in this specification or not. 3.9 Hydraulic analysis of fire water ring main network including line size, flow and pressure at various section of the system shall be submitted for Owner/Consultant’s approval 3.10 The detail design shall take into consideration of all stipulations, practices followed by Statutory Regulations/Authoriies for al types of jobs of this package. 3.11 Preparation of PFD/ P&ID's and equipment data sheets. Preparation of material take-off, material requisitions and purchase requisition of bought out items. Design calculations for the respective fire protection system, Installation, drawings and documents, Operating, maintenance and spare parts manuals wherever applicable. 3.12 Taking approval from statutory authorities. 40 FIRE PROTECTION PHILOSOPHY The Fire Protection Philosophy is based on Loss Preventive and Control, The importance of adequate fire protection facilities need not be emphasized as no plant is absolutely safe because of the inherent hazard it carries. A fire in one partsection of the plant can endanger other sections of plant as well. If fire breaks out, it must be controlled / extinguished as quickly as possible to minimize the loss to life and property and to prevent further spread of fire. 50 GENERAL CONSIDERATIONS The following fire protection facilities shall be provided depending upon the nature or the installation and risk involved + Fire Water System + Gas Flooding ( proven equivalent ) System ‘+ Carbon Dioxide Flooding System + Dry Chemical Extinguishing System + Portable fire fighting equipment 60 FIRE WATER SYSTEM Fire Water System shall be designed as per NEPA Code and complied with Local Law! Indian Standards/ Civil Defense requirements / National Building Code- 2016. 6.1 Fire Fighting System 1) Fire Hydrant shall be provided in a ring round the facilities of the plant and storage area in the contractor scope. 2) Fire Fighting System design and layout is subject to review and approval by Local Statutory Authorities. Documentation & obtaining approval of the fire fighting system from local fire service authority shall be in scope of contractor. 3) Contractor shall calculate the fire water requirement and tie-in for scope shall be taken from the OSBL fire water network. Offsite fire water network (OSBL scope) shall be available around the unit. Contractor shall take the required tappings from this Offsite header with an isolation valve for each tapings, 4) Valves on fire water mains shall be of Gate type with rising stem, only, Valves on fire water lines shall be located in RCC valve chamber provided with top cover to FORM NO. 02.0000-0021 FS REVS rights reserved AL) ELECTRICAL DISTRIBUTION SYSTEM] pormencoaeovaz ] TALHER FERTILIZERS UNITED eee LO Bhar PDIL) | FIRE FIGHTING SYSTEM Sea bare Fertlzers | facilitate easy operation/ maintenance of valves. The top of chamber shall be 80 mm above ground level. 5) Fire Protection system's detailed location map to be displayed at Fire Station & Plant Control Rooms. 70 FIRE WATER DISTRIBUTION SYSTEM 7.1 General i) Fire hydrant ring from battery limit tapping point with isolation Gate valve, hydrants, monitors and deluge valve system and accessories to be provided. ii) Indoors hydrants for plant and non-plant buildings shall be provided as required. i) Single headed hydrant for inside the buildings and double headed hydrants for outside building shall be used. iv) For process units, external ring header with hydrants and an internal distribution with monitors and hose reels shall be installed ¥)_ Along the network, a number of block (gate type) valves shall be located in such a way that the various areas of the plant can be fed with fire water even during maintenance operations on part of the fire water network, Gate valve shall be provided at every 300m and at crossings (Junctions) to ensure easy maintenance and uninterrupted water supply in case of break down and shall be planned in such a way that outage of any section of fire water line should not affect other section Vi) Fire water shall not be used for any other purpose. vil) Extension of hydrants/monitors for spill fire (as required by TAC) shall also to be provided. vill) Diesel oil storage tank areas shall be surrounded by hydrants & water cum foam monitors (SS304 body & nozzle, fixed stand post type, manual operation, 500-750 USGPM variable type flow, self inducting foam induction mechanism) along with portable type foam cans (each 200 Litres capacity). ix) Cast Iron as MOG for piping items in the fire fighting system shall not be used 72 Hydrant The hydrants shall be wet barrel type, self-standing, 4” size with 2 separate hydrant valves (material of construction SS304) on each stand post & hose connection 2-1/2" with gate type isolation valves at vertical portion of hydrant. 73 Fire Box Each Fire Box shall consist of two fire hoses having 2-1/2" diameter and 30 M length, one adjustable flow nozzle(material of construction SS304) and hose coupler (material of construction $8304). Fire boxes shall be installed so that each fire box can be reached from two hydrants, Hose boxes shall be made of M.S, material and painted red with dimensions 18 SWG thick M.S. sheet, size 750 mm x 600 mm x 250 mm. 7.4 Monitor Monitor, fixed type, UL listed, material of construction $$304, shall be installed for the protection of high columns and process structures. Monitors capacity shall be 2580 LPM Higher capacity may be achieved with higher pressure. Monitor shall be manually FORM NO. 02.0000-0021 FS REVS rights reserved a ELECTRICAL DISTRIBUTION SYSTEM | pcreeuooaseonaa1 ] TAL CHER FERTILIZERS LMIED eee LO Bhar PDIL) | FIRE FIGHTING SYSTEM a Fertlzers | operated. The monitors shall be suitable for combination of straight and fog jet; the straight jetto-fog change is obtained manually. Water Monitor shall be BIS marked IS: 8442, However to meet the jet-fog combination as specified UL listed monitor with 750 GPM shall be considered 7.5 Fixed Water Spray System Automatic fixed water spray system, designed in accordance with NFPA 15, with automatically pneumatically operated deluge valve having manual by-pass valve system & detectors, shall be installed to the following locations: + Each Cable Cellar shall be fire protected by CO2/DCP type fire extinguisher of suitable capacity, + Both High Velocity Water Spray (HVWS) System and Nitrogen Injection Fire Prevention and Extinguishing System (NIFPES) shall be provided for transformers fire protection of capacity more then 60 MVA. * Nitrogen Injection Fire Prevention and Extinguishing System (NIFPES) shall be provided for transformers fire protection of capacity more the 20MVA. + Both High Velocity Water Spray (HVWS) System shall be provided for transformers fire protection having oil capacity more than 2000 Liters, Other fre protection systems including Fire hydrants, monitors and Fire Extinguishers etc. shall be provided for transformer having oil capacity upto 2000 Liters. 7.6 Hose Reel Hose reel, connected to fire water network, preferably shall be provided in sufficient numbers at various required locations. Each hose reel shall be equipped with a valve 1- 1/2" size, 30 meters of fire hose and water branch pipe. 7.7 Hose Box (Indoor Hydrant) Hose reel, connected to fire water network, preferably shall be located in the warehouses and process units. Each hose box shall be equipped with a hose cabinet, valve (1-1/2" size), 20 meters fire hose and water branch pipe 7.8 Standpipe and Hose System Standpipes with hose stations for Class III (NFPA 14) service are preferred, having one 2- 1/2 inch valve hose connection and 1-1/2" valve hose connection with 30 m lengths of 1- 41/2" fire hose and 1-1/2" water branch pipe, for the protection of selected buildings 79 Sprinkler System ‘The sprinkler system, wet type, shall be designed according to NFPA 13, Sprinklers system shall be installed in the hall and rooms, as applicable. 8.0 GAS FLOODING SYSTEM 81 GAS/ CLEAN AGENT FLOODING FIRE EXTINGUISHING SYSTEM Clean Agent (Inergen or Argonite) System shalll be provided to Rack Room, Panel room, Computer rack room and Control Room, as applicable. FORM NO. 02.0000-0021 FS REVS rights reserved ante PDIL) | ELECTRICAL DISTRIBUTION SYSTEM | poveacmnonSconaa1 ] TALCHER FERTILIZERS LIMITED tier Document No. Rev FIRE FIGHTING SYSTEM Shoot 7 ofS Fertilizers | 82 9.0 10.0 10 12.0 13.0 CARBON DIOXIDE GAS FLOODING FIRE EXTINGUISHING SYSTEM Carbon dioxide gas flooding fire extinguishing system shall be provided for + Electrical panels at substations & other locations. PORTABLE FIRE EXTINGUISHERS Portable fire extinguisher shall be provided for all plant buildings. Wheeled type (40 kg charge) and portable type (6 kg charge) dry powder extinguishers, suitable for class ABC fire, shall be provided as per NFPA requirements. Portable type (6 kg charge) and wheeled (30kg charge) Carbon Dioxide extinguishers shall be provided for fire fighting in the electrical substation and control rooms and other agreed locations as per NFPA requirements. Contractor shall specify the numbers and location for Owner's review and approval DCP Units of 50 Kg and 75 Kg for areas like large oil consoles, substations, flammable gas etc, as applicable. FIRE PROTECTION FOR DIESEL TANK ‘Adequate fire protection requirements shall be provided by bidder for Diesel tank as per NFPA and PESO. BREATHING APPARATUS SET Breathing apparatus set (UL listed) with shouldered type compressed air cylinders shall be provided, minimum 3 nos. in each control room & each substation, for emergency use, (Online air mask (UL listed) shall be provided along with each Breathing apparatus set. SAFETY ITEMS. Bidder shall provide safety items as per hazard requirements, in accordance with NBC- 2016/TACINFPA. Safety shower shall be provided, as applicable EXECUTION, INSPECTION AND TESTING If the system packager/manufacturer is collaborating with any foreign party for basic engineering, design, etc, he should provide certificate of collaboration and first submission of design and detailed drawing shall be approved by the Collaborator. The Contractor shall supply recommended spares for first 24 months of operation and maintenance and subsequent requirements, All execution, inspection and testing for completion of fire protection system shall be carried out based on Codes, standards and specifications. Contractor shall develop a detail inspection, and testing procedures based on codes, standards and specifications. Following minimum tests but not limited to, shall be carried out after completion of the system testing Fire water network piping ‘* Demonstration test for system capacity requirements. ‘© Demonstration test for water spray & sprinkler systems, ‘+ Demonstration test for gas flooding system, ‘The Contractor shall meet all requirements for inspection and testing of the system, FORM NO. 02.0000-0021 FS REVS rights reserved TL | ELECTRICAL DISTRIBUTION SYSTEM | ~pereasoaseoneaa ] a TALGNER FERTEIZERS MITED | her PDIL) | FIRE FIGHTING SYSTEM a Fertlzers | 14,0 DOCUMENTATION Drawings and documents shall be prepared as required by approval authorities in all respects and submitted by the Contractor. The Contractor shall make arrangement for inspection and testing for statutory authorities at various stages of the work. FORM NO. 02.0000-0021 FS REVS rights reserved

You might also like