0% found this document useful (0 votes)
68 views5 pages

Building Inspection Template

This document contains a preliminary structural integrity assessment of a building. It provides general information about the building such as its location, description, and ownership details. It also describes the building's structural system including the number of stories, materials used, and intended occupancy. The main body of the document involves a detailed inspection of various structural elements like the foundation, columns, beams, slabs, walls, shear walls, and roof framing. It lists potential defects that were checked for in each element and notes whether any significant structural issues were observed. The assessment aims to identify cracks, damage, deterioration or instability in the building's structure.

Uploaded by

Bob Shadow
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views5 pages

Building Inspection Template

This document contains a preliminary structural integrity assessment of a building. It provides general information about the building such as its location, description, and ownership details. It also describes the building's structural system including the number of stories, materials used, and intended occupancy. The main body of the document involves a detailed inspection of various structural elements like the foundation, columns, beams, slabs, walls, shear walls, and roof framing. It lists potential defects that were checked for in each element and notes whether any significant structural issues were observed. The assessment aims to identify cracks, damage, deterioration or instability in the building's structure.

Uploaded by

Bob Shadow
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 5

PRELIMINARY STRUCTURAL INTEGRITY ASSESSMENTS

I. GENERAL INFORMATION

Region
Province
City/Municipality
Barangay

INSPECTION

Inspector/s:

Inspection Date
Time:

II. BUILDING INFORMATION

Building Name
Building description
Address
Building Owner/Administrator/Contact Person
Address
Contact No.
No. of Story Above Ground:

Type of Building:

Concrete Frame Composite Steel-Concrete


Steel Frame Other types, pls. specify
RC Shear Wall Reinforced Masonry
Timber Frame Unreinforced Masonry

Type of Structure:

Built-Up Section Cast-in-place


Rolled Section Combination
Pre-cast Other types, specify

Designed Occupancy:

Public Assembly Offices School


Health Center Industrial Evacuation Center
Commercial Historical Other uses, specify

Date Constructed
Age of Structure
III. STRUCTURAL

1. Building Site
a. Existence of earth Fissures
b. Budged Ground
c. Soil Creep
d. none of the above
2. Foundation
a. Settlement (meter)
b. Tilting (degree)
c. Scouring
d. stable and no sign of settlement

3. Columns
a. Cracks
diagonal/vertical/
horizontal cracks
b. Broken, Buckled or Fractured
c. Joints Separation
d. Spalling
Exposure of reinforcing bars
e. Changes in the Vertical
Alignment
f. Detached Bracing/s
g. Corrosion of Steel Member
h. Evidence of Termite Infestation
i. no significant structural defects
4. Beams
a. Cracks
diagonal/vertical/
horizontal cracks
b. Excessive Deflection
c. Spalling
Exposure of reinforcing bars
d. Separation from vertical
support
e. Beam-column joint failure
f. Corrosion of Steel Member
g. Evidence of Termite Infestation
h. no significant structural defects

5. Slab
a. Cracks
Along vertical plane of beam edge
Punching Shear
b. Sagging
c. Leaks
d. Separation from vertical
support (failure at columns)
e. Spalling
Exposure of reinforcing bars
f. Evidence of Termite Infestation
g. no significant structural defects
6. Wall
a. Cracks
diagonal/vertical/
horizontal cracks
b. Separation of Joints/Connec-
c. Spalling
Exposure of reinforcing bars
d. Evidence of Termite Infestation
e. no significant defects

6. Shear Walls
a. Spalling and exposure of
vertical reinforcement at
boundary elements
b. Horizontal cracks 3mm(1/8")
or larger extending through
boundary elements.
c. Shear failure at piers
d. Failed spandrel beams
e. no significant structural defects

7. Roof Framing
a. Separation from Wall
b. Cracks/Fractured at welded
connections
c. Buckling of members
d. Corrosion of Steel Members
e. Sagging
f. Evidence of Termite Infestation
SERIES OF CRACKS OR SUBSIDENCE/BANGAD

slow movement of soil on the slope

errosion of soilsorounding a bridge foundatio


/BANGAD

ridge foundation