Performance Data Sheet
Model: High Flow Series/HF40 and HF40-S
Use Replacement Cartridge HF40 or HF40-S
The concentration of the indicated substances in water entering the system was reduced to a concentration
less than or equal to the permissible limit for water leaving the system as specified in NSF/ANSI Standard 42 and NSF/ANSI Standard 53
System tested and certified by NSF International against NSF/ANSI Standard 42 and Standard 53 for the reduction of
substances as listed below according to Standard 42 and Standard 53.
Capacity: See chart on page 2
Contaminant Reduction Determined by NSF testing.
Substance Reduction Average NSF/ANSI specified Avg % Average Product Max Permissible Product NSF/ANSI NSF Test
Influent Challenge Reduction Water Concentration Water Concentration Reduction Report
Concentration Requirements
Chlorine Taste and Odor 2.0 mg/L 2.0 mg/L ± 10% 96.6% 0.07 mg/L N/A ≥ 50% J-00089365
Nominal Particulate Class 3,833,333 At least 10,000 99.5% 19,883 pts/mL N/A ≥85% J-00047325
I,≥ 0.5 µm to ≤ 1.0 µm pts/mL particles/mL
Cyst* 107,750 cysts/L Minimum 50,000 cysts/L 99.99% 5 cyst/L N/A ≥99.95% J-00092653
* Based on the use of Cryptosporidium parvum oocysts
FOR COMMERICIAL USE ONLY
Application Guidelines/Water Supply Parameters WARNING
Service Flow See chart on page 2 To reduce the risk associated with ingestion of contaminants:
Do not use with water that is microbiologically unsafe or of unknown quality without
Water Supply Potable Water adequate disinfection before and after the system. Systems certified for cyst reduction may be
Water Pressure 25 -125 psi (172 – 862 kPa) used on disinfected water that may contain filterable cysts.
Water Temperature 40º F - 100º F (4.4º C - 38º C) EPA Establishment Number 070595-CT-001
CAUTION
It is essential that the manufacturer’s recommended installation, maintenance and filter To reduce the risk associated with property damage due to water leakage:
replacement requirements be carried out for the product to perform as advertised. See • Read and follow Use Instructions before installation and use of this system.
Installation Manual for Warranty information. • Installation and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds125 psi (862 kPa). If your water pressure exceeds 80
Note: While the testing was performed under standard laboratory conditions, actual psi, you must install a pressure limiting valve. Contact a plumbing professional if you are
uncertain how to check your water pressure.
performance may vary.
• Do not install where water hammer conditions may occur. If water hammer conditions exist you
must install a water hammer arrester. Contact a plumbing professional if you uncertain how to
Replacement Cartridge: HF40 or HF40-S. For estimated costs of replacement elements check for this condition.
please call 866.990.9785 9785 or visit our website at www.3Mpurification.com • Do not install on hot water supply lines. The maximum operating water temperature of this filter
system is 100º F (38º C).
• Protect filter from freezing. Drain filter when temperatures drop below 40ºF (4.4ºC).
Parts and service available from:
• The disposable filter cartridge must be replaced every 6 months or at the specified service
cycle, or sooner, if a noticeable pressure drop occurs.
3M Purification Inc.
400 Research Parkway
Meriden, CT 06450, U.S.A.
Tel 866.990.9785 3M is a trademark of 3M Company.
203.237.5541 © 2012 3M Company. All rights reserved.
Fax 203.238.8701 NSF is a trademark of NSF International
www.3Mfoodservice.com INSTR4245 0912B
www.3Mpurification.com
Page 1 of 2
Performance Data Sheet
Model: High Flow Series
Use Replacement Cartridge HF40 or HF40-S
HF40 and HF40-S Cartridge Flow and Capacity Information
Head & Manifold # of Cartridges Flow Rate Flush Instruction Capacity
NH3-½ Series Head 1 2.1 gpm (7.95 lpm) Flush 4.5 gallons through cartridge(s) before use 25,000 gallons (94,635 liters)
(flush approximately 2 minutes)
VH3 Series Head 1 2.1 gpm (7.95 lpm) Flush 4.5 gallons through cartridge(s) before use 25,000 gallons (94,635 liters)
(flush approximately 2 minutes)
High Flow Series, DF 1XX Flush 4.5 gallons through cartridge(s) before use
Manifold 1 2.1 gpm (7.95 lpm) (flush approximately 2 minutes) 25,000 gallons (94,635 liters)
High Flow Series, DF2XX Flush 8.5 gallons through cartridge(s) before use
Manifold 2 4.2 gpm (15.9 lpm) (flush approximately 2 minutes) 50,000 gallons (189,270 liters)
Twin Manifold Assembly, Flush 8.5 gallons through cartridge(s) before use
2XX Series 2 4.2 gpm (15.9 lpm) (flush approximately 2 minutes) 50,000 gallons (189,270 liters)
Triple Manifold Assembly, Flush 12.6 gallons through cartridge(s) before use
3XX Series 3 6.3 gpm (23.8 lpm) (flush approximately 2 minutes) 75,000 gallons (283,905liters)
DF Single Manifold Flush 4.5 gallons through cartridge(s) before use
Assembly, DF 1XX Series 1 2.1 gpm (7.95 lpm) (flush approximately 2 minutes) 25,000 gallons (94,635 liters)
DF Twin Manifold Flush 8.5 gallons through cartridge(s) before use
Assembly, DF2XX Series 2 4.2 gpm (15.9 lpm) (flush approximately 2 minutes) 50,000 gallons (189,270 liters)
DP Single Manifold Flush 4.5 gallons through cartridge(s) before use
Assembly, DP 1XX Series 1 2.1 gpm (7.95 lpm) (flush approximately 2 minutes) 25,000 gallons (94,635 liters)
DP Twin Manifold Flush 8.5 gallons through cartridge(s) before use
Assembly, DP2XX Series 2 4.2 gpm (15.9 lpm) (flush approximately 2 minutes) 50,000 gallons (189,270 liters)
DP Triple Manifold Flush 12.6 gallons through cartridge(s) before use
Assembly, DP3XX Series 3 6.3 gpm (23.8 lpm) (flush approximately 2 minutes) 75,000 gallons (283,905liters)
SF Single Manifold Flush 4.5 gallons through cartridge(s) before use
Assembly, SF 1XX Series 1 2.1 gpm (7.95 lpm) (flush approximately 2 minutes) 25,000 gallons (94,635 liters)
Page 2 of 2