org/electricity-monitoring/ct-sensors/interface-with-
arduino?redirected=true
To connect a CT sensor to an Arduino, the output signal from the CT sensor needs to be
conditioned so it meets the input requirements of the Arduino analog inputs, i.e. a positive
voltage between 0V and the ADC reference voltage.
Note: This page give the example of an Arduino board working at 5 V and of the EmonTx
working at 3.3 V. Make sure you use the right supply voltage and bias voltage in your
calculations that correspond to your setup.
This can be achieved with the following circuit which consists of two main parts:
If the CT sensor is a "current output" type such as the YHDC SCT-013-000, the current
signal needs to be converted to a voltage signal with a burden resistor. If it is a voltage
output CT you can skip this step and leave out the burden resistor, as the burden resistor is
built into the CT.
The YHDC SCT-013-000 CT has a current range of 0 to 100 A. For this example, let's
choose 100 A as our maximum current.
c) Divide the peak-current by the number of turns in the CT to give the peak-current
in the secondary coil.
The YHDC SCT-013-000 CT has 2000 turns, so the secondary peak current will be:
Secondary peak-current = Primary peak-current / no. of turns = 141.4 A
/ 2000 = 0.0707A
If you're using an Arduino running at 5V: AREF / 2 will be 2.5 Volts. So the ideal burden
resistance will be:
35 Ω is not a common resistor value. The nearest values either side of 35 Ω are 39 and 33
Ω. Always choose the smaller value, or the maximum load current will create a voltage
higher than AREF. We recommend a 33 Ω ±1% burden. In some cases, using 2 resistors in
series will be closer to the ideal burden value. The further from ideal the value is, the lower
the accuracy will be.
The emonTx V3 uses a 3.3V regulator, so it's VCC and therefore AREF, will always be 3.3V
regardless of battery voltage. The standard emonTx V3 uses 22Ω burden resistors for CT
1, 2 and 3, and a 120Ω resistor for CT4, the high sensitivity channel. See the emonTx V3
technical wiki
at: https://wiki.openenergymonitor.org/index.php?title=EmonTx_V3#Burden_Resistor_Calc
ulations.
The EmonPi has two CT channels both with 22Ω burden resistors.
emonTx V2
If you're using a battery powered emonTx V2, AREF will start at 3.3 V and slowly decrease
as the battery voltage drops to 2.7 V. The ideal burden resistance for the minimum voltage
would therefore be:
Ideal burden resistance = (AREF/2) / Secondary peak-current = 1.35V /
0.0707A = 19.1 Ω
Tool for calculating burden resistor size, CT turns and max Irms (thanks to Tyler Adkisson
for building and sharing this).
(Note: this tool does not take into account maximum CT power output. Saturation and
distortion will occur if the maximum output is exceeded. Nor does it take into account
component tolerances, so the burden resistor value should be decreased by a few (~5)
percent allow some "headroom." There is more info about component tolerances at: ACAC
Component tolerances.)
Adding a DC Bias
If you were to connect one of the CT wires to ground and measure the voltage of the
second wire, relative to ground, the voltage would vary from positive to negative with
respect to ground. However, the Arduino analog inputs require a positive voltage. By
connecting the CT lead we connected to ground, to a source at half the supply voltage
instead, the CT output voltage will now swing above and below 2.5 V thus remaining
positive.
Resistors R1 & R2 in the circuit diagram above are a voltage divider that provides the 2.5 V
source (1.65 V for the emonTx). Capacitor C1 has a low reactance - a few hundred ohms -
and provides a path for the alternating current to bypass the resistor. A value of 10 μF is
suitable.
We use 10 kΩ resistors for mains powered monitors. The emonTx uses 470 kΩ resistors to
keep the power consumption to a minimum, as it is intended to run on batteries for several
months.
Arduino Sketch
To use the above circuit to measure RMS current, with an assumed fixed RMS voltage
(e.g. 240V) to indicate approximate apparent power, use this Arduino sketch: Arduino
sketch - current only