0% found this document useful (0 votes)
151 views

Welcome To The Allegro DCVG Webinar: Hosted by Lon Duke

The document discusses the Allegro system from American Innovations including hardware components, data management, GPS setup, and digital volt meter functionality. It provides information on configuration, maintenance, and use of external GPS units with the Allegro system.

Uploaded by

mhd abdou
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
151 views

Welcome To The Allegro DCVG Webinar: Hosted by Lon Duke

The document discusses the Allegro system from American Innovations including hardware components, data management, GPS setup, and digital volt meter functionality. It provides information on configuration, maintenance, and use of external GPS units with the Allegro system.

Uploaded by

mhd abdou
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 71

American Innovations

Welcome to the Allegro DCVG Webinar


Hosted by Lon Duke

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro

Hardware Components
Data Management
GPS Setup
DCVG Survey

[email protected]
1-800-229-3404, select 1, then press 3

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations
Allegro - Overview

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro - Hardware

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Hardware

 Survey Mode Adjustment

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Hardware

Digital Volt Meter – DVM


- PCMCIA Card

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Power/Reset

Basic Reset
MX – Power Button
 Warm=Reset
 Cold=Power Off

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Data Management

Data Files

Files are stored in:


 \Storage\AI\
 \SD Card\AI\

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Data Management

To your PC
File Explorer

To SD card
‘SD Card’

To USB Flash
‘Hard Disk’

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Data Management

Syncing to your Laptop / PC


Connection Options
 USB Cradle or direct USB cable
 Serial Cable

Windows XP
 MS ActiveSync
Windows Vista & Windows 7
 Windows Mobile Device Center

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

AI Programs loaded on Allegro

AiDvm
CeCi
DCVG
GpsStatus
Periodic Survey

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Versions
Current Release
MX - 4.4.0

Verify Release
Open an AI Application; i.e. ‘DCVG’
DCVG : View / About

How can I get the latest


version?
Technical Support Engineers:
Steve Brown Nick Klaudt
‘Dub’ Woods Tony Faulkner
Website: www.aiworldwide.com

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro – Maintenance
Warm Boot
 Solves a majority of Windows memory and port issues

Touchscreen
 Utilize Screen Protectors

Battery
 Average about 1-1.5 yrs of use
 Keep compartment closed
 Extend NiMH battery life by not leaving on charger 24/7

DVM Calibration
 Per your Company guidelines, but typically annual recertification
 Third-party contact

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


GPS

© 2011 American Innovations — Confidential


American Innovations

Allegro Datum Configuration


GPS Configuration
 Datum (WGS-84) is primary datum
 Configure For
 Accuracy
 Signal Acquisition
 Compromise

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

GPS Status
‘FF’ means invalid GPS
packets

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Allegro won’t sync


Set up
 GPS Pod Setup
 NMEA
 9600 BAUD
 Parity – None
 Stop Bit 1
 GGA, GSA, VTG, ZDA

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Gps Status

‘V’ means valid


GPS packets

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

GPS Status

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

External GPS Units

Holux
ProXRS ProXT & XH

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

GPS Setup

Go to Start and choose GPS


Status.
The unit will be using the
Internal GPS of the Allegro
and should be receiving
satellites (8 satellites in
view) and see the time
packet (10:32:13 AM PZ).
Click the Options button.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

External GPS Setup

Click the Port box to


change to the
appropriate COM.
In this case we are
choosing COM1. This is
the serial port.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

External GPS Setup

After changing the Port to


COM1 the “Read PPS from
Internal GPS” is now
enabled so you can select
this option. Check the box.
This will allow a Sub-Meter
data stream to the Allegro
AND get the Time packet
(PPS) from the internal
GPS. Click OK.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

External GPS Setup

The first number is


the external GPS
The second is the
internal

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

External GPS Setup

In the DCVG program


we have Differential
GPS identified by the
“D” in the lower right

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

External GPS Setup

When we lose our time


packet it is identified by the
“(HiLo)”.
If you notice we are still
receiving the DGPS data for
the location.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


AI DVM

© 2011 American Innovations — Confidential


American Innovations

DVM – Digital Volt Meter

 At first Test Station of


each morning, verify
interruption by using the
DVM Graph option
 Click Options

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DVM On/Off Mode

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

On/Off - GPS Sync

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DVM Setup “Options” – GPS tab

Comm Port option allows to


assign the port that GPS data
stream is being received from.
Typically is set to COM3
(internal) at 9600 Baudrate

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DVM – On/Off mode and GPS Sync


We can tell we are
locked into due to the
“GPS” and number of
satellites “(7)” and we
have received the time
packet as identified by
“PZ”.
To verify interruption with
wave form, click the
“Graph” button.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DVM Setup – Graph/Wave Form


To view the graph with “On”
cycle on top, you must change
your upper range to “-2.2” and
lower range to “-1”
Shaded = “On” cycle
Two vertical dashed lines are
where the Allegro is taking the
On/Off reads based on the
delay settings
Triangles identify the cycle is
beginning in the “On”
This matches the interrupter
setting

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


DCVG

ANSINACE Standard RP0502-2002 Item No. 21097

© 2011 American Innovations — Confidential


American Innovations

What is a DCVG Survey?

Holiday Voltage
Gradients

Pipeline

Groundbed

•Cell to cell readings of IR gradients


•Used to identify and size defects in coatings

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey Equipment and settings

 Survey Mode Adjustment

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

 For DCVG surveys, it is often necessary to increase


the output of the cathodic protection rectifier to provide
sufficient IR drop for DCVG measurement.
 Since we have increased the rectifier output, we want
to decrease the duration of the ON cycle to avoid
over-polarization. Typically change the interrupter
cycle to give a shorter ON and longer OFF cycle.
◦ Ex: .3s ON and .7s OFF.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations
DCVG Survey

Holiday Voltage
Gradients

Pipeline

Groundbed

0.05

0.03

0.01

-0.01

-0.03

-0.05

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey Setup

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey Mode

Flagged mode is
the recommended
survey mode
since you are not
using a chainer.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey On/Off Settings


On/Off settings
are GPS Sync
or High/Low
To minimize
polarization of
the pipeline
during the IR
drop, increase
the output of the
rectifier and
change the
cycle to a longer
Off than On

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey Data


Enter the On/Off
values for the
beginning and the end
of the survey
The values entered in
the DCVG tab will be
stored in the header of
the survey file
The difference
between the On and
Off is the Signal
Strength value
The polarity display
can be disabled

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG GPS Setup

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey Screen


The DCVG
application will
display the
On/Off values
and the DCVG
reading
The DCVG
reading is the On
– Off

The GPS status


is displayed at
the bottom

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Polarity On
An arrow is
displayed to show
the polarity when
the Show Polarity
option is enabled
The arrow is
displayed for
voltages outside
+/-3mv
Right for positive
Left for negative

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Polarity On

A negative IR
Gradient value

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Polarity Off

Show Polarity is
disabled
The IR gradient
is displayed as
an absolute
value
The arrow is not
displayed

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


0

-0.06
-0.04
-0.02
0.02
0.04
0.06

0.015
0.025
0.035
0.045

0.005
0
0.01
0.02
0.03
0.04
0.05
1057
1057 1063
1063 1069
1069 1075
1075 1081
1081 1087
1087 1093
1093

© 2012 American Innovations — Confidential


1099
1099 1105
1105 1111
1111 1117
1117 1123
1123 1129
1129 1135
1135 1141
DCVG Survey Data

1141 1147
1147 1153
American Innovations

1153 1159
1159 1165
1165 1171
1171 1177
1177 1183
1183 1189
1189 1195
1195 1201
1201 1207
1207 1213

Polarity Off
Polarity On

1213 1219
1219 1225
1225 1231
1231 1237
1237 1243
1243 1249
1249 1255
1255 1261
1261 1267
1267 1273
1273 1279
1279 1285
1285 1291
1291 1297
1297
1303
1303
1309
1309
1315
1315
1321
1321
1327
1327
1333
1333
1339
1339
1345
1345
Remote Monitoring  Compliance Solutions  CP Systems
American Innovations

Move Menu

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Move Menu – Go To Location

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Move Menu – Go To Location

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Remarks List

Using the number in the


search box will quickly find
and populate the caption to
the remarks field

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey – Remarks List

Selected remark is now in


the Remarks field
Multiple Remarks can be
added

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey – Remarks List Editing

The Remarks list is found in


the Storage\AI\CiData folder
and can opened on the
Allegro in order to modify this
list.

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Survey – Remarks List Editing

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Options - Misc

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Options - File

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Options - GPS

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Options - Colors

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Indication
View>Test Point
Information
(Ctrl +T)
The Defect sizing
screen will be the
first option in the
Test Point
Information list

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations
DCVG Indication
The Total IR and %IR are
calculated after the defect
data has been collected

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations
DCVG Indication

A summary of
the defect data
is displayed in
the information
section
The defect data
is saved in the
remarks field

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Indication

Defect
information in
Single Record
mode

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

DCVG Data Files

DCVG application
AI standard = .DVG
Excel-compatible/flat file =
.CSV

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations
DCVG Data

Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


Any Questions??
[email protected]
800-229-3404, select 1, then press 3

Want even more Allegro Training? Contact Christopher Shawhan


[email protected] or 1-512-249-3404

© 2011 American Innovations — Confidential


American Innovations

AI User’s Group
Conference 2012
October 8-11th in Austin, TX @
Omni Southpark Hotel
Training, best practices and Q&A for Allegro,
PCS (including Version 8), Bullhorn and all other AI products
Allegro training includes a Field Trip on Thursday (10/11) for live
training at rectifier site. RFID technology integration featured.
AI does not charge for the training. Attendees only need to pay
for their room directly through the hotel ($200/night).
Reserve your spot today! Details, agenda and registration here:
http://www.aiworldwide.com/usersgroup2012
Remote Monitoring  Compliance Solutions  CP Systems

© 2012 American Innovations — Confidential


American Innovations

Go forth and survey!