Direct solenoid and solenoid pilot operated valves

Series 400
Circuit bar mounting
mid profile - mid profile -
low profile low profile mid profile add-a-unit mid profile add-a-unit
add on style add on style
cylinder ports cylinder ports cylinder ports stations for cylinder ports stations for
cylinder ports cylinder ports
in valve in base in valve CBM403A bar in base CBM404A bar
in valve in base

high profile -
high profile add-a-unit
add on style
cylinder ports stations for
cylinder ports
in base CBM405A bar
in base

Manual operator

Solenoid

4-way pilot with balanced poppet

Bonded spool
2 4

Air return

3 1 5

SERIES FEATURES

• Patented MACSOLENOID® for fastest possible response times


and virtually burn-out proof AC solenoid operation.
• Optional low watt DC solenoids.
• Various manual operators.
• Optional memory spring.
• 2 position or 3 position valve configurations.
• Internal or external pilot.

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
low profile
5/2 - 5/3 1/8” - 1/4” 1.0Cv cylinder ports
in valve

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Port size Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

1/8” NPT Internal 411A-COA-DM-DXXX-XXX


411A-AOA-DM-D 421A-AOA-DM-DXXX-XXX 451A-AOA-DM-DXXX-XXX 461A-AOA-DM-DXXX-XXX 471A-AOA-DM-DXXX-XXX
1/4” NPT 411A-BOA-DM-DXXX-XXX 421A-BOA-DM-DXXX-XXX 451A-BOA-DM-DXXX-XXX 461A-BOA-DM-DXXX-XXX 471A-BOA-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR ** CBM401A-xxxxx-xx


Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

3/8” NPTF Internal CBM401A-00AAA-XX CBM401A-00BAA-XX CBM401A-02AAA-XX CBM401A-02BAA-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.

O P T I O N S

411A-AOA-DM-DXXX-XXX

- clic with memory spring (replace by 4).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : 20 - 150 PSI

Pilot pressure : 20 - 150 PSI


Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.
• Mounting screw (x2) : 35043.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

108.5 94.3

18.5
16.0

CL

14 14 14 14 14.5
3
3

82.0 41.0

118.0 DOUBLE 94.5


67.5
1
1

108.2 SINGLE

12 12 12 12
5
5

7.0

25.0 39.0 19.5 6.7 27.8


É” 6.50 TYP.
31.5
50.7

3/8" PORTS 1/8" PORTS


21.5 TYP. TYP.
32.0

CL

25.0

64.0

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
low profile
5/2 - 5/3 1/8” 1.0Cv cylinder ports
in base

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

Internal 413A-OOA-DM-DXXX-XXX 423A-OOA-DM-DXXX-XXX 453A-OOA-DM-DXXX-XXX 463A-OOA-DM-DXXX-XXX 473A-OOA-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) ** CBM402A-xxxxx-xx


Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

1/8” NPTF Internal CBM402A-00AAA-XX CBM402A-00BAA-XX CBM402A-02AAA-XX CBM402A-02BAA-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.

O P T I O N S

413A-OOA-DM-DXXX-XXX

- clic with memory spring (replace by 6).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : 20 - 150 PSI

Pilot pressure : 20 - 150 PSI


Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.
• Mounting screw (x2) : 35043.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

108.5 94.3

18.5
16.0

CL

14 14 14 14 14.5
3

82.0 41.0

118.0 DOUBLE 94.5


67.5
1

108.2 SINGLE

12 12 12 12
5

7.0

6.7 Ø 6.50 TYP. 27.8


31.5
50.7
1/8" PORTS
TYP.

3/8" PORTS
21.5
TYP.
32.0

CL

25.0

64.0

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
mid profile
5/2 - 5/3 1/8” - 1/4” 1.0Cv cylinder ports
in valve

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Port size Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

1/8” NPT Internal 411A-COA-DM-DXXX-XXX


411A-AOA-DM-D 421A-AOA-DM-DXXX-XXX 451A-AOA-DM-DXXX-XXX 461A-AOA-DM-DXXX-XXX 471A-AOA-DM-DXXX-XXX
1/4” NPT 411A-BOA-DM-DXXX-XXX 421A-BOA-DM-DXXX-XXX 451A-BOA-DM-DXXX-XXX 461A-BOA-DM-DXXX-XXX 471A-BOA-DM-DXXX-XXX
1/8” NPT External 411A-AOD-DM-DXXX-XXX 421A-AOD-DM-DXXX-XXX 451A-AOD-DM-DXXX-XXX 461A-AOD-DM-DXXX-XXX 471A-AOD-DM-DXXX-XXX
1/4” NPT 411A-BOD-DM-DXXX-XXX 421A-BOD-DM-DXXX-XXX 451A-BOD-DM-DXXX-XXX 461A-BOD-DM-DXXX-XXX 471A-BOD-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR ** CBM403A-xxxxx-xx


Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

3/8” NPTF Internal CBM403A-00AAA-XX CBM403A-00BAA-XX CBM403A-02AAA-XX CBM403A-02BAA-XX


Common external CBM403A-00CAA-XX CBM403A-00DAA-XX CBM403A-02CAA-XX CBM403A-02DAA-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.

O P T I O N S

411A-AOA-DM-DXXX-XXX

- clic with memory spring (replace by 4).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : Internal pilot : 20 - 150 PSI
External pilot : vacuum - 150 PSI
Pilot pressure : 20 - 150 PSI
Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.
• Mounting screw (x2) : 35043.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

125,0 DOUBLE (45)


96,0 SINGLE (45)
32,0 27,75

5 1 3
7,0

CL
4 2
69,5
19,5
100,3 CL
4 2
25,0
5 1 3
38,0
26,5 21,0 20,5 24,5
15,0
Ø 6,5
8,0

14,5
3/8"
32,0
1/8” EXTERNAL
41,0
PILOT PORT
67,5 (OPTIONAL)
82,0

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
mid profile -
5/2 - 5/3 1/8” - 1/4” 1.0Cv add on style
cylinder ports
in valve

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Port size Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

1/8” NPT Internal 411A-COA-DM-DXXX-XXX


411A-AOA-DM-D 421A-AOA-DM-DXXX-XXX 451A-AOA-DM-DXXX-XXX 461A-AOA-DM-DXXX-XXX 471A-AOA-DM-DXXX-XXX
1/4” NPT 411A-BOA-DM-DXXX-XXX 421A-BOA-DM-DXXX-XXX 451A-BOA-DM-DXXX-XXX 461A-BOA-DM-DXXX-XXX 471A-BOA-DM-DXXX-XXX
1/8” NPT External 411A-AOD-DM-DXXX-XXX 421A-AOD-DM-DXXX-XXX 451A-AOD-DM-DXXX-XXX 461A-AOD-DM-DXXX-XXX 471A-AOD-DM-DXXX-XXX
1/4” NPT 411A-BOD-DM-DXXX-XXX 421A-BOD-DM-DXXX-XXX 451A-BOD-DM-DXXX-XXX 461A-BOD-DM-DXXX-XXX 471A-BOD-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR ** CBM403A-xxxxx-xx


Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

3/8” NPTF Internal CBM403A-00ABA-XX CBM403A-00BBA-XX CBM403A-02ABA-XX CBM403A-02BBA-XX


Common external CBM403A-00CBA-XX CBM403A-00DBA-XX CBM403A-02CBA-XX CBM403A-02DBA-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.
Note: add-a-unit stations may be added to above bars.

O P T I O N S

411A-AOA-DM-DXXX-XXX

- clic with memory spring (replace by 4).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : Internal pilot : 20 - 150 PSI
External pilot : vacuum - 150 PSI
Pilot pressure : 20 - 150 PSI
Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01. • End plate kit for common external : M-04004-01.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

113.0 99.0
100.3
24.5
Ø 6.5 TYP.
21.0

15.0
CL CL
7.0

117.5 DOUBLE 14.5


27.8
14 14 14 14
32.0
3

32.0
3

82.0 107.9 SINGLE 41.0


4

67.5
18.0
1

1
2

12 12 12 12
5
5

1/8" EXTERNAL
PILOT PORT
8.0 OPTIONAL
25.0
19.5 6.5

40.5 3/8" PORTS


1/8" PORTS TYP.
TYP. 8 PLACES
55.0 21.0 16.0

20.5
380

C
CL

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
add-a-unit
5/2 - 5/3 1/8” - 1/4” 1.0Cv stations for
CBM403A bar

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Port size Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

1/8” NPT Internal 411A-COA-DM-DXXX-XXX


411A-AOA-DM-D 421A-AOA-DM-DXXX-XXX 451A-AOA-DM-DXXX-XXX 461A-AOA-DM-DXXX-XXX 471A-AOA-DM-DXXX-XXX
1/4” NPT 411A-BOA-DM-DXXX-XXX 421A-BOA-DM-DXXX-XXX 451A-BOA-DM-DXXX-XXX 461A-BOA-DM-DXXX-XXX 471A-BOA-DM-DXXX-XXX
1/8” NPT External 411A-AOD-DM-DXXX-XXX 421A-AOD-DM-DXXX-XXX 451A-AOD-DM-DXXX-XXX 461A-AOD-DM-DXXX-XXX 471A-AOD-DM-DXXX-XXX
1/4” NPT 411A-BOD-DM-DXXX-XXX 421A-BOD-DM-DXXX-XXX 451A-BOD-DM-DXXX-XXX 461A-BOD-DM-DXXX-XXX 471A-BOD-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR ** CBM403A-xxxxx-xx


Port size Pilot air Spacing 21 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

3/8” NPTF Internal CBM403A-01AEA-XX CBM403A-01BEA-XX CBM403A-02AEA-XX CBM403A-02BEA-XX


Common external CBM403A-01CEA-XX CBM403A-01DEA-XX CBM403A-02CEA-XX CBM403A-02DEA-XX

Number of stations (01, 02, 03, or 04)


** Other options available. Consult factory.

O P T I O N S

411A-AOA-DM-DXXX-XXX

- clic with memory spring (replace by 4).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : Internal pilot : 20 - 150 PSI
External pilot : vacuum - 150 PSI
Pilot pressure : 20 - 150 PSI
Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04001. • Flow control (x2) : N-04001. • Seal (x2) : 17013-01, (x1) : 17015-01.
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01. • End plate kit for common external : M-04004-01.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

113.0 99.0
100.3
24.5
Ø 6.5 TYP.
21.0

15.0
CL CL
7.0

117.5 DOUBLE 14.5


27.8
14 14 14 14
32.0
3

32.0
3

82.0 107.9 SINGLE 41.0


4

67.5
18.0
1

1
2

12 12 12 12
5
5

1/8" EXTERNAL
PILOT PORT
8.0 OPTIONAL
25.0
19.5 6.5

40.5 3/8" PORTS


1/8" PORTS TYP.
TYP. 8 PLACES
55.0 21.0 16.0

20.5
380

C
CL

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
mid profile
5/2 - 5/3 1/8” - 1/4” 1.0Cv cylinder ports
in base

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

Internal 413A-OOA-DM-DXXX-XXX 423A-OOA-DM-DXXX-XXX 453A-OOA-DM-DXXX-XXX 463A-OOA-DM-DXXX-XXX 473A-OOA-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) ** CBM404A-xxxxx-xx


Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

1/8” NPTF Internal CBM404A-00AAA-XX CBM404A-00BAA-XX CBM404A-02AAA-XX CBM404A-02BAA-XX


1/4” NPTF Internal CBM404A-00AAD-XX CBM404A-00BAD-XX CBM404A-02AAD-XX CBM404A-02BAD-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.

O P T I O N S

413A-OOA-DM-DXXX-XXX

- clic with memory spring (replace by 6).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : 20 - 150 PSI

Pilot pressure : 20 - 150 PSI


Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.
• Mounting screw (x2) : 35043.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

125,0 DOUBLE (45)

96,0 SINGLE (45)


32,0 27,8

5 1 3
7,0

CL
4 2
69,5
19,5
100,3 CL
4 2
25,0
5 1 3
38,0
26,5 21,0 20,5 24,5
15,0

4 2
14,5
3/8 " PORTS B A
41,0
67,5
82,0

Port size A B

1/8” 31.5 19.0


1/4” 32.0 20.0

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
mid profile -
5/2 - 5/3 1/8” - 1/4” 1.0Cv add on style
cylinder ports
in base

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

Internal 413A-OOA-DM-DXXX-XXX 423A-OOA-DM-DXXX-XXX 453A-OOA-DM-DXXX-XXX 463A-OOA-DM-DXXX-XXX 473A-OOA-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) ** CBM404A-xxxxx-xx


Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

1/8” NPTF Internal CBM404A-00ABA-XX CBM404A-00BBA-XX CBM404A-02ABA-XX CBM404A-02BBA-XX


1/4” NPTF Internal CBM404A-00ABD-XX CBM404A-00BBD-XX CBM404A-02ABD-XX CBM404A-02BBD-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.
Note: add-a-unit stations may be added to above bars.

O P T I O N S

413A-OOA-DM-DXXX-XXX

- clic with memory spring, replace by 6.

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : 20 - 150 PSI

Pilot pressure : 20 - 150 PSI


Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

113.0
100.3
24.5
É” 6.5 TYP.
21.0

15.0
CL CL
117.5 DOUBLE 14.5
14 14 14 14
3

32.0
3

99.0
82.0 107.9 SINGLE 41.0
67.5
1
1

7.0
12 12 12 12
5
5

1/8" EXTERNAL
PILOT PORT 27.8
OPTIONAL 31.5
50.5
25.0 8.0
2 2 2 2
19.5 6.5

40.5 3/8" PORTS 4 4 4 4


TYP.

1/8" PORTS
55.0 21.0 16.0 TYP. 8 PLACES

20.5
42.0 26.5
38.0

C
CLL

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
add-a-unit
5/2 - 5/3 1/8” - 1/4” 1.0Cv stations for
CBM404A bar

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

Internal 413A-OOA-DM-DXXX-XXX 423A-OOA-DM-DXXX-XXX 453A-OOA-DM-DXXX-XXX 463A-OOA-DM-DXXX-XXX 473A-OOA-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR (BOTTOM CYLINDER PORTS) **


CBM404A-xxxxx-xx
Port size Pilot air Spacing 21 mm Spacing 26 mm (Rectangular connector)
w/o flow controls w/ flow controls w/o flow controls w/ flow controls

1/8” NPTF Internal CBM404A-01AEA-XX CBM404A-01BEA-XX CBM404A-02AEA-XX CBM404A-02BEA-XX


1/4” NPTF Internal CBM404A-01AED-XX CBM404A-01BED-XX CBM404A-02AED-XX CBM404A-02BED-XX

Number of stations (01, 02, 03, or 04)


** Other options available. Consult factory.

O P T I O N S

413A-OOA-DM-DXXX-XXX

- clic with memory spring (replace by 6).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : 20 - 150 PSI

Pilot pressure : 20 - 150 PSI


Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04002. • Flow control (x2) : N-04001. • Seal : 16525.
• Mounting screw (x2) : 35043. • End plate kit : M-04003-01.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

113.0
100.3
24.5
É” 6.5 TYP.
21.0

15.0
CL CL
117.5 DOUBLE 14.5
14 14 14 14
3

32.0
3

99.0
82.0 107.9 SINGLE 41.0
67.5
1
1

7.0
12 12 12 12
5
5

1/8" EXTERNAL
PILOT PORT 27.8
OPTIONAL 31.5
50.5
25.0 8.0
2 2 2 2
19.5 6.5

40.5 3/8" PORTS 4 4 4 4


TYP.

1/8" PORTS
55.0 21.0 16.0 TYP. 8 PLACES

20.5
42.0 26.5
38.0

C
CLL

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
high profile
5/2 - 5/3 1/8” - 1/4” 1.0Cv cylinder ports
in base

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

Internal 413A-OOA-DM-DXXX-XXX 423A-OOA-DM-DXXX-XXX 453A-OOA-DM-DXXX-XXX 463A-OOA-DM-DXXX-XXX 473A-OOA-DM-DXXX-XXX


External 413A-OOD-DM-DXXX-XXX 423A-OOD-DM-DXXX-XXX 453A-OOD-DM-DXXX-XXX 463A-OOD-DM-DXXX-XXX 473A-OOD-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) ** CBM405A-xxxxx-xx


Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm
(Rectangular connector)

1/8” NPTF Internal CBM405A-00AAA-XX CBM405A-02AAA-XX


Common external CBM405A-00BAA-XX CBM405A-02BAA-XX
1/4” NPTF Internal CBM405A-00AAD-XX CBM405A-02AAD-XX
Common external CBM405A-00BAD-XX CBM405A-02BAD-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.

O P T I O N S

413A-OOA-DM-DXXX-XXX

- clic with memory spring (replace by 6).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18
MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : Internal pilot : 20 - 150 PSI
External pilot : vacuum - 150 PSI
Pilot pressure : 20 - 150 PSI
Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.

Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

5 1 3
25,0
7,0
CL
4 2 19,5
69,5
CL
4 2

5 1 3

59,0

125,0 DOUBLE (45)


96,0 SINGLE (45)
32,0

114,3

2
52,0
40,0 22,0
33,5
19,0
4 9,5
20,0
35,0

3/8" PORTS 46,0


72,0

1/8” EXTERNAL
PILOT PORT
(OPTIONAL)

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
high profile -
5/2 - 5/3 1/8” - 1/4” 1.0Cv add on style
cylinder ports
in base

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

Internal 413A-OOA-DM-DXXX-XXX 423A-OOA-DM-DXXX-XXX 453A-OOA-DM-DXXX-XXX 463A-OOA-DM-DXXX-XXX 473A-OOA-DM-DXXX-XXX


External 413A-OOD-DM-DXXX-XXX 423A-OOD-DM-DXXX-XXX 453A-OOD-DM-DXXX-XXX 463A-OOD-DM-DXXX-XXX 473A-OOD-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **


CBM405A-xxxxx-xx
Port size Pilot air Spacing standard 19,5 mm Spacing 26 mm
(Rectangular connector)

1/8” NPTF Internal CBM405A-00ABA-XX CBM405A-02ABA-XX


Common external CBM405A-00BCA-XX CBM405A-02BCA-XX
1/4” NPTF Internal CBM405A-00ABD-XX CBM405A-02ABD-XX
Common external CBM405A-00BCD-XX CBM405A-02BCD-XX

Number of stations (03=3 stations)


** Other options available. Consult factory.
Note: add-a-unit stations may be added to above bars.

O P T I O N S

413A-OOA-DM-DXXX-XXX

- clic with memory spring (replace by 6).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : Internal pilot : 20 - 150 PSI
External pilot : vacuum - 150 PSI
Pilot pressure : 20 - 150 PSI
Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.
• End plate kit : M-04005-01. • End plate kit for common external pilot : M-04006-01.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

113.0 114.3
40.0
33.5
19.0

118.0 DOUBLE
20.0
3

14 14 14 14
35.0
98.5 SINGLE 46.0
72.0
84.0 99.0
1

1
5

12 12 12 12
7.0

1/8" EXTERNAL
PILOT PORT
OPTIONAL 59.0
21.0 3/8" PORTS
21.0 TYP.

10.5 16.0
55.0 9.5 Ø 6.50
TYP 2

4 16.0

52.0
2 21.0
20.0

Consult “Precautions”before use, installation or service of MAC Valves.


Direct solenoid and solenoid pilot operated valves

Series 400
Function Port size (NPTF) Flow (Max) Circuit bar mounting
add-a-unit
5/2 - 5/3 1/8” - 1/4” 1.0Cv stations for
CBM405A bar

OPERATIONAL BENEFITS
1. The 4-way pilot develops maximum shifting forces
both ways.
2. Memory spring available.
3. Balanced spool, immune to variations of pressure,
also provides high flow.
4. Short stroke with high flow.
5. Bonded spool with minimum friction, shifting in a
glass-like finished bore.
6. Pilot with balanced poppet, high flow, short and
consistent response times.
7. Wiping effect eliminates sticking. Reset
8. Long service life.

HOW TO ORDER xxxx-xxx-DM-Dxxx-xxx


HOW TO ORDER VALVE FOR CIRCUIT BAR MOUNTING
Pilot air 5/2 5/2 5/3 5/3 5/3
Single operator Double operator Closed center Open center Pressure center
2 4 12 2 4 14 12 2 4 14 12 2 4 14 12 2 4 14
12 14

315 315 3 15 3 15 3 15

Internal 413A-OOA-DM-DXXX-XXX 423A-OOA-DM-DXXX-XXX 453A-OOA-DM-DXXX-XXX 463A-OOA-DM-DXXX-XXX 473A-OOA-DM-DXXX-XXX


External 413A-OOD-DM-DXXX-XXX 423A-OOD-DM-DXXX-XXX 453A-OOD-DM-DXXX-XXX 463A-OOD-DM-DXXX-XXX 473A-OOD-DM-DXXX-XXX

SOLENOID OPERATOR ➤ D XX X- X XX *

XX Voltage X Wire length X Manual operator XX Electrical connection

JB 240/60, 220/50 A 18” (Flying leads) 1 Non-locking KA Square connector


JA 120/60, 110/50 J Connector 2 Locking KD Square connector
with light
JC 24/60, 24/50 x Other Options x Other Options JB Rectangular connector
FB 24VDC (1.8 W) JD Rectangular connector
with light
DA 24VDC (5.4 W) BA Flying leads
DF 24VDC (12.7 W) xx Other Options
xx Other Options

HOW TO ORDER CIRCUIT BAR (SIDE CYLINDER PORTS) **


CBM405A-xxxxx-xx
Port size Pilot air Spacing 21 mm Spacing 26 mm
(Rectangular connector)

1/8” NPTF Internal CBM405A-01AEA-XX CBM405A-02AEA-XX


Common external CBM405A-01BEA-XX CBM405A-02BEA-XX
1/4” NPTF Internal CBM405A-01AED-XX CBM405A-02AED-XX
Common external CBM405A-01BED-XX CBM405A-02BED-XX

Number of stations (01, 02, 03, or 04)


** Other options available. Consult factory.

O P T I O N S

413A-OOA-DM-DXXX-XXX

- clic with memory spring (replace by 6).

Consult “Precautions”before use, installation or service of MAC Valves.


100% WARRANTY

OF
PRODUCTION
TESTED

100%
18 MONTHS

Series 400

T E C H N I C A L
D A T A

Fluid : Compressed air, vacuum, inert gases


Pressure range : Internal pilot : 20 - 150 PSI
External pilot : vacuum - 150 PSI
Pilot pressure : 20 - 150 PSI
Lubrication : Not required, if used select a medium aniline point lubricant (between 180°F to 210°F)
Filtration : 40 µ
Temperature range : 0°F to 120°F (-18°C to +50°C)
Orifice : 6.2 mm
Flow : 1.0Cv
Leak rate : 50 cm3/min
Coil : General purpose class A, continuous duty, encapsulated
Voltage range : -15% to +10% of nominal voltage
Protection : NEMA 4
Power : ∼ Inrush : 10.9 VA Holding : 7.7 VA
= 1.8 to 12.7 W
Response times : 24 V=/5.4 W Energize : 7.3 ms De-energize : 5.3ms
60Hz/6 W Energize : 8-12 ms De-energize : 7-11 ms

Spare parts : • Pilot valve : DMB-DXXX-XXX-1, including mounting screws 35069 and seal 16524.

Accessories : • Blanking plate : M-04002. • Seal : 16525. • Mounting screw (x2) : 35043.
• End plate kit : M-04005-01. • End plate kit for common external pilot : M-04006-01.
Options :
• BSPP threads. • Isolation of inlet and/or exhaust.

DIMENSIONS

113.0 114.3
40.0
33.5
19.0

118.0 DOUBLE
20.0
3

14 14 14 14
35.0
98.5 SINGLE 46.0
72.0
84.0 99.0
1

1
5

12 12 12 12
7.0

1/8" EXTERNAL
PILOT PORT
OPTIONAL 59.0
21.0 3/8" PORTS
21.0 TYP.

10.5 16.0
55.0 9.5 Ø 6.50
TYP 2

4 16.0

52.0
2 21.0
20.0

Consult “Precautions”before use, installation or service of MAC Valves.


Section 2 Options

Consult “Precautions” before use, installation or service of MAC Valves.


O p t i o n s

OPTIONS

Codification table for voltages / Wire length / Manual operator / Electrical connection

VALVE CODE ➤ D M - D XX X - X XX
1 2 3 4

OPTIONS AVAILABLE FOR

- pilot operated valves 400, 52 & 92 Series

Consult “Precautions”before use, installation or service of MAC Valves.


Back
OPTIONS

1. VOLTAGE

- D XX X - X XX VOLTAGE
DB 12 VDC (5.4 W)
DC 12 VDC (7.5 W)
DD 24 VDC (7.3 W)
DE 12 VDC (12.7 W)
DK 110 VDC (5.8 W)
DJ 28 VDC (5.7 W)
DL 64 VDC (6.0 W)
DM 36 VDC (5.8 W)
DN 6 VDC (6.0 W)
DR 90 VDC (6,6 W)
DS 110 VDC (7.3 W), 100 VDC (6.0 W)
DT 75 VDC (5.6 W)
DP 48 VDC (5.8 W)
FA 12 VDC (1.8 W)
FE 12 VDC (2.4 W)
FF 24 VDC (2.4 W)
JD 100/60, 100/50, 110/60

2. WIRE LENGTH

- D XX X - X XX WIRE LENGTH
B 24”
C 36”
D 48”
E 72”
F 96”

Consult “Precautions”before use, installation or service of MAC Valves.


O p t i o n s

OPTIONS
Back

3. MANUAL OPERATOR

- D XX X - X XX MANUAL OPERATOR
0 No operator
1 Non-locking recessed
2 Locking recessed
3 Non-locking extended
4 Locking extended

4. ELECTRICAL CONNECTION

- D XX X - X XX ELECTRICAL CONNECTION
BA Flying leads
BK BA with protection diode
BL BA with protection varistor
CA 1/2" NPS conduit
JB Rectangular connector
JD Rectangular connector with light
JM Rectangular connector, male only
KA Square connector
KB Square connector with protection diode
KC Square connector with protection varistor
KD Square connector with light
KE Square connector with light and protection diode
KF Square connector with light and protection varistor
KJ Square connector (male only)
KK Square connector with protection diode (male only)
KL Square connector with protection varistor (male only)
TA Dual tabs
TB TA with protection diode
TD TA with light
TE TA with light and protection diode
TJ Dual tabs (male only)
TK TJ with protection diode
TM TJ with light
TN TJ with light and protection diode
* DN Plug-in with diode
* DP Plug-in with M.O.V.
* DH Plug-in with diode & ground
* DJ Plug-in with M.O.V & ground
* These options only apply to the 92 series. All others are for the 400 and 52 series.

Consult “Precautions”before use, installation or service of MAC Valves.


PRECAUTIONS CONCERNING THE APPLICATION,
INSTALLATION AND SERVICE OF MAC VALVES

The precautions below are important to be read and understood before MANUAL OPERATORS-
designing into a system any MAC valve, and before installing or servicing any MAC
valve. Improper use, installation or servicing of any MAC valve in some systems could Most MAC valves can be ordered with manual operators. Manual operators when
create a hazard to personnel or equipment. depressed, are designed to shift the valve to the same position as would the
corresponding solenoid or remote air pilot operator if it were activated. Care must be
taken to order a type, if any, that will be safe for the physical location of the manual
APPLICATION PRECAUTIONS : operator in the system. Accidental activation of a manual operator could create a
dangerous situation. If intentional or accidental operation of a valve by a manual
INDUSTRIAL USE - operator could create a dangerous situation then the "no operator" option should be
used.
MAC valves are intended for use in industrial pneumatic and/or vacuum systems. They
are not intended for consumer use or service. They are general purpose industrial valves REMOTE AIR OPERATED VALVES
with literally thousands of different applications in industrial systems. These products are
not inherently dangerous, but they are only a component of an overall system. The Pilot valves supplying signal pressure to remote air operated valves should be 3-way
system in which they are used must provide adequate safeguards to prevent injury or valves with adequate supply and exhaust capacity to provide positive pressurizing and
damage in the event failure occurs, whether it be failure of switches, regulators, exhausting of the pilot supply line. Pilot lines should be open to exhaust when valves
cylinders, valves or any other component. are deenergized.

INSTALLATION AND SERVICE PRECAUTIONS :


POWER PRESSES -
A. Do not install or service MAC valves without first making sure both the air and
MAC valves are not designed nor intended to be used to operate and/or control the electrical power to the machine are off and that all air has been completely bled
operation of clutch and/or brake systems on power presses. There are special products from the system.
on the market for such use.
B. MAC valves should only be installed and/or serviced by qualified, knowledgeable
personnel who understand how the specific valve is to be pneumatically piped and
2-POSITION VALVES - electrically connected (where applicable). Flow paths through the valve are shown
in the catalog and on the valve by use of ANSI or ISO type standard and graphic
Some MAC valves are 2-position, 4-way valves. When air is supplied to the inlet port(s) symbols. Do not install unless these symbols and the valve functions and operations
of these valves, there will always be a flow path from the inlet to one of the outlets are thoroughly understood.
regardless of which of the two positions the valve is situated. Therefore, if pressurized
air retained in the system would present a hazard in the application or servicing of the C. Before service, maintenance, repair or cleaning, consult local distributor or factory
valve or system, a separate method in the system must be provided to remove the for Parts & Operation Sheet and information on proper cleaning and lubrication
trapped air. agents. Do not subject MAC valves’ parts to any foreign substance including
lubricants and cleaning agents not specifically recommended by MAC valves, Inc.

3- POSITION VALVES- D. MAC valves are never to be stepped on while working on a machine. Damage to
the valve, or lines to the valve (either air or electrical lines) or accidental activating
Some MAC valves are 3-position, 4-way valves. These valves are either double solenoid of a manual operator on the valve could result in a dangerous condition.
or double remote air operated.
If either of the two operators is in control, air supplied to the inlet port(s) will pass
through the valve to one of the outlets as on 2-position, 4-way valves. However, if WARNING :
neither operator is in control, the valve moves to a center position. Listed below are the
various center position functions : Under no circumstances are Mac valves to be used in any application where failure of
the valve to operate as intended could jeopardize the safety of the operator or any
other person.
A. CLOSED CENTER- - Do not operate outside of pressure range listed on valve label or outside of
designated temperature range.
With this type valve, when in the center position all ports are blocked (inlets and - Air supply must be clean. Contamination of valve can affect proper operation.
exhausts) meaning the air at both outlet ports is trapped. If trapping the air in both outlet - Before attempting to repair, adjust or clean valve, consult catalog, parts & operation
ports would present a hazard in the application or servicing, a separate method in the sheet, or factory for proper maintenance procedures, lubrication, and cleaning agents.
system must be provided to remove the trapped air or this type valve should not be Never attempt to repair or perform other maintenance with air pressure to valve.
used. - If airline lubrication is used, consult catalog, parts & operation sheet, or factory for
recommended lubricants.

B. OPEN CENTER- LIMITATION OF GUARANTEE

With this type valve, when in the center position, the inlet port(s) is blocked and the two This Guarantee is limited to the replacement or rebuilding of any valve which should
outlet ports are open to the exhaust port(s) of the valve. If having no air in either outlet fail to operate properly. Valves, under the MAC Guarantee, must be returned (with or
port would present a hazard in the application or servicing, this type valve should not without bases) transportation prepaid and received at our factory within the Guarantee
be used. period. They will be returned to the customer at the expense of MAC Valves, Inc., and
will carry the same guarantee as provided under the Flat Rate Rebuild Program.

C. PRESSURE CENTER-
DISCLAIMER OF GUARANTEE
With this type valve, when in the center position, the inlet port(s) is connected to both
outlet ports of the valve. If having pressurized air to either or both outlet ports would No claims for labor, material, time, damage, or transportation are allowable nor will
present a hazard in the application or servicing of the valve or system, a separate any valve be replaced or rebuilt under this guarantee which has been damaged by the
method in the system must be purchaser not in the normal course of its use and maintenance during the warranty
provided to remove the retained air. period. The guarantee does not apply to loss or damage caused by fire, theft, riot,
explosion, labor dispute, act of God, or other causes beyond the control of MAC
Valves,Inc. MAC Valves, Inc. shall in no event be liable for remote, special or
OPERATING SPECIFICATIONS - consequential damages under the MAC Guarantee, nor under any implied warranties,
including the implied warranty of merchantability.
MAC valves are to be installed only on applications that meet all operating
specifications described in the MAC catalog for the valve. The above Guarantee is our manner of extending the engineering and service
resources of the MAC Valves, Inc. organization to assure our customer long, and
continued satisfaction.