PROJECT
PROPOSED FOR RESIDENTIAL VILLAS PROJECT
CLIENT
M/s. VERTEX HOMES PVT. LTD.
CONSULTANTS
OPTIMAL MEP CONSULTANTS
SUBJECT
INTERNAL ELECTRICAL WORKS BOQ
S.NO DESCRIPTION UNIT E2 TOTAL RATE AMOUNT
1 ISI PVC Conduit Heavy duty for ceiling & Medium duty for wall SUPPLY INSTALLATIO SUPPLY INSTALLATIO
N N
Modular Switches & socket
Supply & Installation of conduit wiring for light/power consisting of a) Wiring in ISI PVC conduit on ceiling/concealed in concrete
slab/wall complete with GI pull wire, conduit fittings, conduit accessories like saddles, spacers, bends, couplings, collars etc.,
junction / pull / inspection boxes, conduit supports, bushings lamp holders, ceiling rose, flexible conduit/ inspection L bends &
terminations using tinned copper lugs of crimping type. Individual junction/inspection boxes shall be provided for each lighting
fitting for the purpose of looping from fitting to fitting. No. of wires in conduit shall be limited as per relevent standard. 6A
switch, front cover plate & Back boxes to be considered in the point wiring
b) 1100V grade FRLS copper wires/flexible cable as specified.
c) Job includes necessary chipping and including cost of civil finishes
(1) From DB to first Switch board will be termed as Circuit Wiring
(2) From Switch board to first light/socket/fan will be termed as primary point
(3) From primary point to subsequent loop point on the same circuit shall be termed as secondary point.
EB METERING BOX TO LIFT & ELECTRICAL VECHICLE CHARGER
Supply,Wiring and Commisioning of the 4Rx1Cx 6 sq.mm (R,Y,B,N) + 2Rx1Cx4 sq.mm (E) PVC insulated copper conductor 1100
1.1 volts grade stranded flexible FRLS wires and all necessary teriminations, wiring accessories in Existing conduits etc.. Mtr. 35 35 300 75 10500 2625
Supply,Wiring and Commisioning of the 2Rx1Cx4 sq.mm (E) PVC insulated copper conductor 1100 volts grade stranded
1.2 flexible FRLS wires and all necessary teriminations, wiring accessories in Existing conduits etc..( For Lift dedicated Earthing) Mtr. 30 30 100 15 3000 450
EB METERING BOX TO VILLA DB & AC ODU
Supply,Wiring and Commisioning of the 4Rx1Cx10 sq.mm (R,Y,B,N) + 2Rx1Cx6 sq.mm (E) PVC insulated copper conductor 1100
1.3 volts grade stranded flexible FRLS wires and all necessary teriminations, wiring accessories in Existing conduits etc.. Mtr. 90 90 350 100 31500 9000
Supply,Wiring and Commisioning of the 2Rx1Cx6 sq.mm (E) PVC insulated copper conductor 1100 volts grade stranded
1.4 flexible FRLS wires and all necessary teriminations, wiring accessories in Existing conduits etc.. ( For VRV dedicated Earthing) Mtr. 55 55 120 15 6600 825
2
POINT WIRING SYSTEM
ISI PVC Conduit Heavy duty for ceiling & Medium duty for wall
2.1 Wiring Light / exhaust fan point
Supplying all materials and wiring for light points/exhaust fan using 3 runs of 1.5 mm² 1.1kV grade PVC insulated FRLS copper
conductor single core stranded wires run continously as per IS through PVC conduits concealed in wall / slab etc, complete with
necessary accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M.S box with
moulded front plate including earthing the box, etc. complete as required including rough plastering. (Colour coding to be
followed Phase (Red, Yellow, Blue), Neutral- Black & Earth - Green) - ( THE RATE DOES NOT INCLUDED 5A SOCKET WITH BASE
BOX AND FRONT PLATE )
Rate to be quoted for Back box, Front plate, Switch, wire & Conduit Each 85 85 500 220 42500 18700
2.2
Wiring Light point - 2Way
Supplying all materials and wiring for double controlled light points using 3 runs of 1.5 mm² 1.1kV grade PVC insulated FRLS
copper conductor single core stranded wires run continously as per IS through PVC conduits PVC conduits concealed in wall /
slab etc, complete with necessary accessories, including supplying and fixing 6A modular type 2 Way switch housed in a suitable
factory made M.S box with moulded front plate including earthing the box etc.complete as required including rough plastering.
Junction box to be provided below the beam bottom . (Colour coding to be followed Phase(Red, Yellow, Blue), Neutral- Black &
Earth - Green) (2Sets. of 6A 2 Way switch).
Rate to be quoted for Back box, Front plate, Switch, wire & Conduit Each 7 7 1250 230 8750 1610
2.3
Wiring Fan point
Supplying all materials and wiring for fan points with modular stepped 2 module regulator box using 3 runs of 1.5 mm² PVC
insulated FRLS copper conductor single core stranded wires of 1.1kV grade PVC insulated FRLS copper wire continuously run as
per IS through PVC conduits PVC conduits concealed in wall/slab etc., complete with fan hook junction box and necessary
accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M. S. box with moduled
front plate including earthing the box etc. complete as required( Colour coding to be followed Phase(Red, Yellow, Blue), Neutral-
Black & Earth - Green).
Rate to be quoted for Back box, Front plate, Switch, Regulator, wire & Conduit Each 9 9 900 220 8100 1980
2.4
Double Controlled Fan point
Supplying all materials and wiring for fan points with modular stepped 2 module regulator box using 3 runs of 1.5
mm² PVC insulated FRLS copper conductor single core stranded wires of 1.1kV grade PVC insulated FRLS copper
wire continuously run as per IS through PVC conduits PVC conduits concealed in wall/slab etc., complete with fan
hook junction box and necessary accessories, including supplying and fixing 6A modular type 2 way switch housed
in a suitable factory made M. S. box with moduled front plate including earthing the box etc. complete as
required( Colour coding to be followed Phase(Red, Yellow, Blue), Neutral- Black & Earth - Green) (2Sets. of 6A 2 way
switch with 1No.regulator)
Rate to be quoted for Back box, Front plate, Switch, Regulator, wire & Conduit Each 4 4 1100 250 4400 1000
2.5
Wiring call bell points
Supplying all materials and wiring for call bell points using 3 runs of 1.5 mm² PVC insulated FRLS copper conductor single core
stranded wires of 1.1KV grade as earth conductor continuously run as per IS through PVC conduits PVC conduits concealed in
wall/slab etc., complete with necessary accessories, including supplying and fixing 6A modular type bell push, 230V AC buzzer
with indicator housed in a suitable factory made MS box with moulded front plate including earthing the box,rough plastering
etc. Complete as required. ( Colour coding to be followed Phase(Red, Yellow, Blue), Neutral- Black & Earth - Green)
Rate to be quoted for Back box, Front plate, Switch, wire & Conduit Each 1 1 800 180 800 180
2.6
6A Plug points - independent position 0 0
Supplying all materials and wiring for 6A plug points in independent positions including circuit mains using 3 runs of 1.5 mm²
650V grade PVC insulated FRLS copper conductor wire run continously as per IS through PVC conduits concealed in wall / slab
etc, complete with necessary accessories, and fixing 6A modular type 3 pin shuttered plug socket controlled by 6A switch with
moulded front plate, housed in a suitable factory built MS box. Giving connections, earthing the box,rough plastering etc
complete as required. This circuit shall be looped to the lighting circuit.
Rate to be quoted for Back box, Front plate, Switch,socket, wire & Conduit Each 30 30 800 150 24000 4500
2.7
6A Plug points - combined position
Supplying all materials and fixing 6A modular type 3 pin shuttered plug socket controlled by 6A switch with moulded front
plate, housed in a suitable factory built MS box. Giving connections, earthing ,rough plastering etc complete as required. This
circuit shall be looped to the independent socket.
Rate to be quoted for Back box, Front plate, Switch & socket(without wiring) Each 26 26 500 100 13000 2600
2.7
6A Plug points without switch for A/c IDU's
Supplying all materials and fixing 6A modular type 3 pin shuttered plug socket with moulded front plate, housed in a suitable
factory built MS box. Giving connections, earthing ,rough plastering etc complete as required. This circuit shall be looped to the
independent socket.
Rate to be quoted for Back box, Front plate & socket(without wiring) Each 9 9 500 100 4500 900
2.8
6/16A Power plug points
Supply and providing 6/16A combined modular type power plug socket (shuttered) controlled with 16A modular type switch,
mounted on a suitable factory built MS box with earthing facility, giving interconnections etc. and using 3 runs of 2.5 mm² 650V
grade PVC insulated FRLS copper conductor wire run continously as per IS through PVC conduits concealed in wall / slab etc,
Rate to be quoted for Back box, Front plate, Switch & socket.(without wiring & conduit) Each 10 10 950 170 9500 1700
2.9
6/16A Power plug points with IP65 Protection
Supply and providing 6/16A combined modular type power plug socket (shuttered) controlled with 16A modular type switch,
mounted on a suitable factory built MS box with earthing facility, giving interconnections etc. and using 3 runs of 2.5 mm² 650V
grade PVC insulated FRLS copper conductor wire run continously as per IS through PVC conduits concealed in wall / slab etc,
Rate to be quoted for Back box, Front plate, Switch & socket.(without wiring & conduit) QRO
2. 10
Geyser points-socket
Supply and fixing 16A modular type socket in a suitable factory made MS enclosure . complete with connections, testing and
commissioning etc as required
Rate to be quoted for Back box, Front plate, Socket (without wiring & conduit) Each 4 4 850 180 3400 720
PROJECT
PROPOSED FOR RESIDENTIAL VILLAS PROJECT
CLIENT
M/s. VERTEX HOMES PVT. LTD.
CONSULTANTS
OPTIMAL MEP CONSULTANTS
SUBJECT
INTERNAL ELECTRICAL WORKS BOQ
S.NO DESCRIPTION UNIT E2 TOTAL RATE AMOUNT
2. 11
Geyser points-switch
Supply and fixing 16A modular type Double pole switch with indicator in a suitable factory made MS enclosure. complete with
connections, testing and commissioning etc as required
Rate to be quoted for Back box, Front plate, Switch, (without wiring & conduit) Each 4 4 300 170 1200 680
2. 12
Data Point
Supply and fixing telephone socket (Data jack single line RJ45)on factory made MS box including supply of box giving
connection etc as required.
Rate to be quoted for jack,plate, box
Each 8 8 350 170 2800 1360
2. 13
Intercom Point
Supply and fixing Intercom socket (RJ 45 Data jack single line )on factory made MS box including supply of box giving
connection etc as required.
Rate to be quoted for jack,plate, box Each 1 1 250 170 250 170
2. 14
TV point
Supply and fixing (For TV jack single line RG6) on factory made MS box including supply of box with front plate with dummy &
necessary accesoories.
Rate to be quoted for Back box, Front plate, dummy plate. Each
7 7 300 200 2100 1400
2. 15 Supply & Installation of Back box with footlamp and necessary Accessories
Each 11 11 300 220 3300 2420
2.16 Supply & Installation of 9W Bulkhead light fixture and necessary Accessories
Each 14 14 900 350 12600 4900
2.17
8 Module ELV junction box with hylum sheet for internal area ( Paint to be matched with the wall) Each 6 6 700 400 4200 2400
2.18
6"X12" Metal junction box with Cover ( Main ELV Junction box @ near by the Metering panel) Each 1 1 2000 750 2000 750
2.19
40A FP RCBO 100mA with Enclosure box Each 1 1 4000 500 4000 500
2.20 Supply, Installation, Testing & Commissioning of 2Cx1.5Sq.mm copper instrumentation cable in existing 40mm dia pvc pie for Mtr. 10 10 175 25 1750 250
water meter to Dual source meter
PROJECT
PROPOSED FOR RESIDENTIAL VILLAS PROJECT
CLIENT
M/s. VERTEX HOMES PVT. LTD.
CONSULTANTS
OPTIMAL MEP CONSULTANTS
SUBJECT
INTERNAL ELECTRICAL WORKS BOQ
S.NO DESCRIPTION UNIT E2 TOTAL RATE AMOUNT
3.0 Lighting & power circuit
ISI PVC Conduit Medium duty for wall open ceiling conduit & Wall concelead conduit
Supply & Installation of conduit wiring for light/power consisting of a) Wiring in ISI PVC conduit on ceiling/concealed in
concrete slab/wall complete with GI pull wire, conduit fittings, conduit accessories like saddles, spacers, bends, couplings, collars
etc., junction / pull / inspection boxes, conduit supports, bushings lamp holders, ceiling rose, flexible conduit/ inspection L bends
& terminations using tinned copper lugs of crimping type. Individual junction/inspection boxes shall be provided for each
lighting fitting for the purpose of looping from fitting to fitting. No. of wires in conduit shall be limited as per relevent standard.
6A switch, front cover plate & Back boxes to be considered in the point wiring
b) 1100V grade FRLS copper wires/flexible cable as specified.
c) Job includes necessary chipping and including cost of civil finishes
(1) From DB to first Switch board will be termed as Circuit Wiring
(2) From Switch board to first light/socket/fan will be termed as primary point
(3) From primary point to subsequent loop point on the same circuit shall be termed as secondary point.
3.1 Circuit Wiring using 2Rx1Cx4 sq.mm & 1Rx1Cx2.5 sq.mm cu flexible wires QRO
3.2 Circuit Wiring using 2Rx1Cx2.5 sq.mm & 1Rx1Cx1.5sq.mm cu flexible wires for the DB to Geyser Mtr. 105 105 180 20 18900 2100
Circuit Wiring using 2Rx1Cx2.5 sq.mm & 1Rx1Cx1.5sq.mm cu flexible wires for the
3.3 DB to Power circuits (for Lift, Kitchen & Iron room only ) Mtr. 115 115 180 20 20700 2300
Circuit Wiring using 2Rx1Cx2.5 sq.mm & 1Rx1Cx1.5sq.mm cu flexible wires for
3.4 the DB to switch board ( For Lift, LCM & AC IDU ) Mtr. 345 345 180 20 62100 6900
3.6 Looping Circuit Wiring using 3Rx1Cx1.5 sq.mm cu flexible wires for the switch board to switch board in 20mm PVC Conduit Pts. 33 33 155 20 5115 660
(average length 9Mtrs)
4.0 TELEPHONE, TV WIRING:
Supply & laying of 0.5sq.mm, 2Pair PVC telephone cable (From the Main ELV JB to points-Tele) (Existing conduit) . ( ELV cable
4.1 fully copper ) QRO 0
Supply & laying of RG-6/u Dual Shielded Coaxial Cable for TV (From the JB to points-TV) (Existing conduit)
4.2 Mtrs. 80 80 25 10 2000 800
Supply & laying of CAT 6 cable (for Data + VDP+RDU)
4.3 Mtrs. 115 115 30 10 3450 1150
Supply & laying of OFC cable
4.4 QRO
5.0 ELECTRICAL & ELV CONDUIT SYSTEM ( INCL. NYLON ROPE WITH ACCESSORIES FOR PULLING PURPOSE )
ISI PVC Conduit Medium duty for wall open ceiling conduit & Wall concelead conduit
Supply and installation of Approved makes of 32 mm PVC conduit with accessories Slab/Floor/Wall conduiting. ( For DB & lift
5.1 from the Electrical Panel ) Mtr. 230 230 40 16 9200 3680
5.2 Supply and installation of Approved makes of 25 mm PVC conduit with accessories Slab/Floor/Wall conduiting. ( for LCM, PCM Mtr. 625 625 20 12 12500 7500
& From the JB to points-Tele)
5.3 Supply and installation of Approved makes of 20 mm and PVC conduit with accessories Slab/Floor/Wall conduiting. ( for LCM, QRO
PCM & From the JB to points-TV)
5.4 Mtr. 10 10 100 20 1000 200
Supply and installation of Approved makes 50 mm and PVC conduit with accessories Slab/Floor/Wall conduiting.
6.0 FINAL DISTRIBUTION BOARDS
Supply, installation, testing and commissioning of the following cubicle type 1.6 mm / Standard thick CRCA sheet steel
enclosed and partitions to segregate phases recessed in wall or surface mounted final distribution boards of the
following description. Distribution board shall be powder coated and double door construction and in four tier configuration.
6 way Vertical TPN DB
6.1 18 Nos. 10/16 amps SP MCB’s as Outgoings with 3 Nos. 40 amps DP 10kA MCB’s as Sub-Incomers and 1 No. 40 amps 4 pole Nos. 1 1 8000 3000 8000 3000
30mA RCCB as an Incomer with separate neutral link for each phase.
4 way Vertical TPN DB
6.2 12 Nos. 10/16 amps SP MCB’s as Outgoings with 3 Nos. 40 amps DP 10kA MCB’s as Sub-Incomers and 1 No. 40 amps 4 pole Nos. 2 2 6000 2500 12000 5000
30mA RCCB as an Incomer with separate neutral link for each phase.
7.0 LT DISTRIBUTION BOARDS
Design,manufacture, supply, unloading, keeping in safe custody/ storage till hand over,shifting to the final location, erection/
installation, testing & commissioning as per sld / statutory requirements of the following electrical equipments. As per client's
requirement factory stage/ final inspections/ tests will also include in the offer.further final decision on whether supply &
installation or only installation is clients decision will be decided later date. LT panel all are MCCBs to be considered above 250A
thermal magnetic only
VILLA METERING BOX ( REF THE DRAWING )
A Nos 1 1 30000 5000 30000 5000
INCOMER:
63A FP MCB - 1No.
Dual Source Energy Meter - 1No. (Dual source, RTC, Remote Display, Digital inputs (Water Meter), Ethernet /RS 485
Communication)
R,Y,B Indication lamps with 6A SP MCB control - 1Set
BUSBAR
1 set - 63A, 4Wire, 16KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC
Busbar supports.
OUTGOING:
40A 30mA FP RCCB - 1 No.
40A 10kA FP MCB - 5 Nos.
Detachable cable gland's plates separate for power & control cables.
Cable entries at Top.
B VILLA METERING BOX( REF THE DRAWING ) Nos
INCOMER:
63A FP MCB - 1No.
Dual Source Energy Meter - 1No.
R,Y,B Indication lamps with 6A SP MCB control - 1Set
BUSBAR
1 set - 63A, 4Wire, 16KA, 415V, TPN Aluminium busbars, interconnections with colour coded heat shrinkable sleeves and SMC
Busbar supports.
OUTGOING:
40A 30mA FP RCCB - 1 No.
40A 10kA FP MCB - 4 Nos.
Detachable cable gland's plates separate for power & control cables.
Cable entries at Top.
LIFT DB
C
12way SPN MCB DB,1 No. 32A Amps FP 30mA RCCB for Lift Machine & 1 No. 25 Amps DP 30mA RCCB as Incomer with 1 Nos. 10
Amps SP 10KA MCB’s and 3 Nos. 16 Amps SP 10KA MCB’s and 2Nos Dummy as Outgoings. ( REF THE SLD ) Separate partition to
be provided for the FP Incomer breaker. Nos 1 1 4000 800 4000 800
12.0 EARTHING- SUPPLY AND INSTALLATION as per IS-3043
Earth pit escavation, electrode installation with common salt/ char coal/ bentonite for chemical earthing ( to achieve the
required earth resistance value), inspection chamber with removable CI / RCC covers inclusive of all civil works. The distance
between two earth electrodes should be 3000mm. While measuring the earth resistance, it should be possible to easily
disconnect the bolts with hand tools. Earth pits permanent identification marks are to be provided both inside and out side.
Dedicated earth pits electrodes connecting insulated conductors should be run UG conduits. All the welded joints should be
coated with bitumen to avoid rusting.All the fastners required like PVC pipes, bolts,nuts, locking serated/ flat/spring washers are
included in the scope.Standard installation drawing attached for your ready ref.
PIPE ELECTRODE: Pipe Earth Electrode using 40 mm dia class-B GI pipe complete as per IS 3043 with salt, charcoal, brick
12.1 masonary chamber with heavy duty RCC cover ( suitable to take fire tender load) tender truckmovement) of 300mm x 300mm x Nos. 3 3 8000 2000 24000 6000
450mm chamber,Seperate test link of GI and Chamber , .Refer the Earth pit insallation dwg.
Villa - 1#
Lift - 2#
12.3 40 x 6 mm GI. Strip with PVC sleeves where ever required Mtrs.
12.4 25 x 6 mm GI. Strip with PVC sleeves where ever required Mtrs.
12.5 40 x 6 mm CU. Strip with PVC Sleeves Mtrs.
12.6 50 x 6 mm GI. Strip with PVC Sleeves Mtrs.
12.7 25 x 6 mm CU. Strip with PVC Sleeves Mtrs.
12.8 25 x 3 mm GI. Strip with PVC Sleeves Mtrs.
12.9 8 SWG GI wire Mtrs. 12 12 100 32 1200 384
12.10 8mm dia GI Rod (inclu. Fixing accessories) Mtrs.
SUB TOTAL 418915 107094