TAP and TAP Controller - VLSI Tutorials
TAP and TAP Controller - VLSI Tutorials
It is the interface used for JTAG control. The IEEE standard de nes four mandatory
TAP signals and one optional TRST signal.
1. TDI (Test Data Input) – It is used to feed data serially to the target.
2. TDO (Test Data Output) – It is used to collect data serially from target.
3. TCK (Test Clock) – It is the clock to the registers.
4. TMS (Test Mode Select) – It controls the TAP controller state transitions.
5. [Optional] TRST (Test Reset) – It resets the TAP controller.
TAP Controller
It controls the JTAG operation. It is basically a 16-state Finite State Machine (FSM)
whose state transitions are controlled by the TMS signal as shown in Figure 2. The
TAP controller can change state only at the rising edge of TCK and the next state is
determined by the logic level of TMS and the present state.
Figure 1: A top level view of TAP Controller
Figure 1 shows a very basic top-level view of TAP controller. TMS, TCK and the
optional TRST signals go to a 16-state FSM, which produces various control signals
depending upon the FSM’s state. These output signals include dedicated control
signals for Instruction Register (IR): CaptureIR, ShiftIR, UpdateIR and generic
control signals for all Data Registers (DR): CaptureDR, ShiftDR, UpdateDR along
with other control signals.
Figure 2: State transition diagram of TAP Controller FSM
A brief description about the di erent states of the TAP controller –
• Run-Test/Idle: This is a state in which the FSM is waiting for some test
operations to complete.
• Capture-DR and Capture-IR: In this state, data can be loaded in parallel to the
corresponding Register
• Shift-DR and Shift-IR: In this state, the required test data is loaded (or unloaded)
serially into (or from) the corresponding Register. If you refer the Figure 2, when the
TAP controller is in this state, it will stay at this state as long as TMS=0. For each
clock cycle, one data bit is shifted into (or out of) the selected Register through TDI
(or TDO).
• Exit1-DR and Exit1-IR: All parallel-loaded (from the Capture-DR and Capture-IR
state) or serial-loaded (from the Shift-DR and Shift IR state) data are held in the
Register in this state.
• Pause-DR and Pause-IR: The FSM pauses its function here to wait for some
external operation
• Exit2-DR and Exit2-IR: This state represents the end of the Pause-DR or Pause-
IR operation, and allows the TAP controller to go back to Shift-DR or Shift-IR state
for more data to be shifted in (or shifted out).
• Update-DR and Update-IR: The test data stored in the rst op of Register
(typically all the Registers have two ops for each bit, we will discuss about it later)
is loaded to the second op in this state.