Lab 1: Study of Single Phase Half Wave Controlled Rectifier Using R-Load and Rl-Load
Lab 1: Study of Single Phase Half Wave Controlled Rectifier Using R-Load and Rl-Load
net/publication/319939728
CITATIONS READS
0 27,601
1 author:
Ajay Singh
Khwopa College of Engineering, Bhaktapur, Nepal
20 PUBLICATIONS 74 CITATIONS
SEE PROFILE
Some of the authors of this publication are also working on these related projects:
Energy Demand Analysis of Household Sector: A Case Study of Bhaktapur View project
PARTICLE SWARM OPTIMIZATION APPROACH FOR DISTRIBUTED GENERATION PLANNING TO IMPROVE VOLTAGE PROFILE MARGIN View project
All content following this page was uploaded by Ajay Singh on 20 September 2017.
OBJECTIVE
To familiarize with the SCR in controlled rectification with resistive (R) and inductive
(L) load.
APPRATUS REQUIRED
1. Thyristor Kit
2. Connecting Wires
3. Oscilloscope
4. Multimeter
THEORY
Single-Phase Half-Wave Controlled Rectifier using R - load
The single-phase half-wave controlled rectifier uses a single thyristor with a load and also
the output voltage and current waveform as shown in figure 1. In a positive half cycle of
source voltage ( 𝑉𝑠 = 𝑉𝑚𝑎𝑥 𝑠𝑖𝑛 𝜔𝑡), thyristor is forward biased and when gate current iG is
applied to the gate terminal at firing angle α then thyristor strarts to conduct. The output
voltage will appear from ωt = α to ωt = π. At ωt = π, thyristor goes turned OFF. In a negative
half cycle, ωt = π to ωt = 2π, thyristor is reverse biased and output voltage is zero during
this period. Therefore, by changing the value of firing angle (α) the output voltage can be
controlled.
The average output voltage is given by:
1 𝜋 𝑉𝑚𝑎𝑥
𝑉𝑑𝑐 = ∫ 𝑉𝑚𝑎𝑥 𝑠𝑖𝑛 𝜔𝑡 𝑑𝜔𝑡 = (1 + 𝑐𝑜𝑠𝛼) (1.1)
2𝜋 𝛼 2𝜋
And rms value of output voltage is given by,
1 𝜋 𝑉𝑚𝑎𝑥 1 1
𝑉𝑟𝑚𝑠 = √ ∫ (𝑉𝑚𝑎𝑥 sin 𝜔𝑡)2 𝑑𝜔𝑡 = ((𝜋 − 𝛼) + sin 2𝛼) ⁄2 (1.2)
2𝜋 𝛼 2√𝜋 2
Figure 1 Single Phase half wave controlled rectifier with resistive load
1 𝛽 𝑉𝑚𝑎𝑥 1 1
𝑉𝑟𝑚𝑠 = √ ∫ (𝑉𝑚𝑎𝑥 sin 𝜔𝑡)2 𝑑𝜔𝑡 = {𝛽 − 𝛼 + (sin 2𝛼 − sin 2𝛽)} ⁄2 (1.4)
2𝜋 𝛼 2√𝜋 2
Figure 2 Single phase half wave controlled rectifier with resistive-inductive load
OBSERVATION
1. Input Parameter
a. Input voltage …………..
b. Frequency .…………..
c. Cycle time period ...…………
2. Observation Table