Extech 391722 Temp Adapter Manual

The DMM Temperature Adapter allows a digital multimeter to measure temperature. It has a temperature range of -20 to 1370°C with an accuracy of +3% to 233°F. The adapter connects to the DMM's voltage input terminals and outputs 1mV per degree. It is powered by a 9V battery and includes a K-type thermocouple temperature probe.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
134 views2 pages

Extech 391722 Temp Adapter Manual

The DMM Temperature Adapter allows a digital multimeter to measure temperature. It has a temperature range of -20 to 1370°C with an accuracy of +3% to 233°F. The adapter connects to the DMM's voltage input terminals and outputs 1mV per degree. It is powered by a 9V battery and includes a K-type thermocouple temperature probe.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DMM Temperature Adapter

1. INTRODUCTION
Congratulations on your purchase of Extech’s DMM Temperature Adapter. This professional
meter, with proper care, will provide years of safe reliable service.

2. SPECIFICATIONS

o o
Temperature Range 0 to 2000 F (-20 to 1370 C)
Output Resolution Adapter output: 1mV per degree C or F
o o o
Accuracy +3% to 233 F (112 C) (+5% above 233 F)
Power Supply DC 9V battery (Heavy duty type).
Weight 5 oz. (142 g )
Dimensions 3 x 2 x 1" (76 x 51 x 25 mm)
Accessories Supplied 9V battery and K-type thermocouple

3. ADAPTER DESCRIPTION

1. Standard DMM displaying temperature


2. Temperature Adapter shown connected
to DMM
3. Power status LED
4. Units select switch for degrees C/F
5. Thermocouple sensor shown attached to
Adapter
NOTE: Battery compartment is on rear of
adapter secured by three screws.

4. OPERATION
4.1 Adapter to DMM Connection
Connect the Adapter to the DMM input terminals via the Adapter's output plugs
observing polarity (the output plug polarity is labeled on the adapter). The positive (+)
Adapter plug connects to the DMM "V" volts input terminal and the Adapter's negative
plug connects to the DMM "COM" (-) input terminal. Power the DMM and set its
function switch to the mV DC range. (Use the VDC setting if mV setting is not
available). If you are using an Auto Range DMM, disable the Auto Range function and
use Manual Range mode.

Test Equipment Depot - 800.517.8431 - 99 Washington Street Melrose, MA 02176


FAX 781.665.0780 - TestEquipmentDepot.com
4.2 Power the Adapter and Select Temperature Units
Move the "OFF/C/F" Switch to either the degrees F or C position as desired. The
Adapter is now powered (observe the red LED power light) and the units of measure
are selected. To remove power to the meter, move this switch to the OFF position and
observe that the red LED indicator extinguishes. If the red status LED does not light
when the meter is switched on, replace battery.

4.3 Measurement Considerations


o
The supplied Type K Thermocouple can measure temperatures up to 650 F. The
Adapter can accept other thermocouples which can measure higher temperatures (up
o
to 2000 F). Contact Extech or you local distributor for other thermocouple probe types.

5. MAINTENANCE
5.1 Battery Replacement
Remove the three (3) Phillips head screws on the rear of the Adapter and open the
housing. Replace the battery and secure the adapter housing.

5.2 Cleaning
Caution: Use only a dry cloth to clean the plastic case.