0% found this document useful (0 votes)
263 views9 pages

Development Length Calculator

The document provides parameters for calculating development length (ld) of reinforcing bars including concrete compressive strength (fc'), steel yield strength (fy), reinforcement location factor (λ), reinforcement type factor (ᴪt), concrete cover factor (ᴪc), and reinforcement relative rib area factor (ᴪr). It gives equations to calculate ld for bars with diameters of 20mm or smaller and 25mm or larger, as well as ld for horizontal bars (ldh) of different diameters. It also provides equations to calculate development length in compression (ldc) based on two cases.

Uploaded by

Ghiovani Dayanan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
263 views9 pages

Development Length Calculator

The document provides parameters for calculating development length (ld) of reinforcing bars including concrete compressive strength (fc'), steel yield strength (fy), reinforcement location factor (λ), reinforcement type factor (ᴪt), concrete cover factor (ᴪc), and reinforcement relative rib area factor (ᴪr). It gives equations to calculate ld for bars with diameters of 20mm or smaller and 25mm or larger, as well as ld for horizontal bars (ldh) of different diameters. It also provides equations to calculate development length in compression (ldc) based on two cases.

Uploaded by

Ghiovani Dayanan
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 9

Parameters

fc' 28 MPa ᴪtᴪe 1.3 OK


fy 420 MPa
λ 1
ᴪt 1.3
ᴪe 1

If all the conditions at column 1 row 1 are met Other cases

20mm and smaller bars 20mm and smaller bars

ld = = 50db ld = 74db

25mm and larger bars 25mm and larger bars

ld = = 61db ld = 94db
Parameters beam width,bw 400 mm
fc' 28 MPa ᴪtᴪe 1.3 OK steel cover,c 40 mm
fy 420 MPa diameter of stirrups, dbs 12 mm
λ 1 main bar diameter, db 25 mm
ᴪt 1.3 No on bars 4 pcs
ᴪe 1 = 0 Spacing ,S 90.33 mm
20mm and smaller bars
ᴪs 0.8 condition (a) 64.50 mm
25mm and larger bars = 1.55 OK condition (b) 45.17 mm
ᴪs 1 cb 45.17
cb 1.81 db

Cb=leser of
a. The distance from center to center of a bar or wire to nearest concrete surface
20mm and smaller bars b. One half the center to center spacing of bars or wires being develop

ld = = 49db

25mm and larger bars

ld = = 61db
ar or wire to nearest concrete surface
ars or wires being develop
Parameters
fc' 28 MPa Factor:
fy 420 MPa
λ 1
ᴪt 1.3
ᴪc 1
ᴪr 1

ldh = = 25db
25
Bar Dia ldh(mm)
10 250
12 300
16 400
20 500
25 625
28 700
Parameters
fc' 28 MPa
fy 414 MPa
λ 1
ᴪr 1

a) ldc = = 19db

b) ldc = = 18db