Customer Details:: Test Reading STD - Reading Error Uncertainty S.No

1) This document is a calibration certificate for a Whirlpool top load washing machine issued by UL India Pvt. Ltd. 2) The calibration was performed onsite on June 5, 2020 and included testing the temperature sensor, digital tachometer, digital timer, wash time, spin time, wash speed, and spin speed. 3) The calibration results showed errors within the measurement uncertainty for each parameter tested.

Uploaded by

mani
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
237 views

Customer Details:: Test Reading STD - Reading Error Uncertainty S.No

1) This document is a calibration certificate for a Whirlpool top load washing machine issued by UL India Pvt. Ltd. 2) The calibration was performed onsite on June 5, 2020 and included testing the temperature sensor, digital tachometer, digital timer, wash time, spin time, wash speed, and spin speed. 3) The calibration results showed errors within the measurement uncertainty for each parameter tested.

Uploaded by

mani
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 2

FR-QT-21 Page 1 of 2

Certificate No : C-200605-7-19 Date of Issue : 08-Jun-20


Date of Calibration : 5-Jun-20 Recom. Due Date : 5-Jun-21
CUSTOMER DETAILS : SRF No. : 200605-7
M/s. UL India Pvt. Ltd., Laboratory Building, Calibrated at : Onsite
Sy.No.129/4, Kalyani Platina, Phase II, Date of Receipt : 05-Jun-20
EPIP Zone, White Field, Bangalore - 560 066. Cond. On Receipt : Satisfactory
DETAILS OF TEST INSRUMENT :
Description : Whirlpool - Top Load Washing Machine Model : 3LWT4840YW1
Range : As Per Report Serial No. : C53820042
Make : Whirlpool Id No. : WHI 01
Least Count : As Per Report Accuracy : --
Location : Colour Fastness Lab
DETAILS OF STANDARD USED :
Sr. No Name ID No. / Sr No. Valid upto Traceability
1 RTD Sensor with Indicator QSC/T/69 2-Jul-20 G & B (Mumbai)
2 Digital Tachometer QSC/M/09 30-Nov-20 G & B (Chennai)
Choose the ty
3 Digital Timer QSC/E/08 23-Sep-20 G & B (Chennai)master senso
Work Instruction No. : WI-TP-01/WI-ET-13/WI-ME-02
Environmental Details : Temperature : 20 ± 2°C Relative Humidity : 65 ± 4 % RH
Calibration Results
Temperature

Test Reading Std.Reading Error Uncertainty


S.No.
°C °C °C °C
1 27 ± 3 27.5 -0.5 0.7
2 41 ± 3 41.9 -0.9 0.7
3 49 ± 3 50.4 -1.4 0.7

Remarks
1. Readings given was the average of 3 Measurements.
2. The reported Expanded Uncertainty is calculated at 95.45 % C.L with coverage factor k=2
3. * marked parameter doesnot covered under our NABL scope.
4. Env. Details mentioned as per customer request.

AUTHORIZED SIGNATORY : P.Muthukumar


DESIGNATION : SM
CALIBRATED BY : Lab Engineer : Chethan K N
ULR NO : CC255920000010863 P
Certificate No : C-200605-7-19 Page 2 of 2

Wash Time

Test Reading Standard Reading Error Uncertainty


Sl.No Parameter
Hr Min Sec 1/100Sec Hr Min Sec 1/100Sec Sec ± Sec
1 Normal 0 16 0 0 0 16 1 586 -1.586 1.35
2 Delicate 0 8 30 0 0 8 35 125 -5.125 1.35

Spin Time

Test Reading Standard Reading Error Uncertainty


Sl.No Parameter
Hr Min Sec 1/100Sec Hr Min Sec 1/100Sec Sec ± Sec
1 Normal 0 5 0 0 0 5 2 95 -2.095 1.35
2 Delicate 0 5 0 0 0 5 1 139 -1.139 1.35

Wash Speed *

Parameter Test Reading Std.Reading Error Uncertainty


S.No.
RPM RPM RPM ±RPM
1 Normal 86 ± 5 86.8 -0.8 0.63
2 Delicate 27 ± 2 27.6 -0.6 0.63

Spin Speed

Parameter Test Reading Std.Reading Error Uncertainty


S.No.
RPM RPM RPM ±RPM
1 Normal 660 ± 20 657.7 2.3 3.89
2 Delicate 500 ± 20 503.6 -3.6 3.89

AUTHORIZED SIGNATORY : P.Muthukumar


DESIGNATION : SM
CALIBRATED BY : Lab Engineer : Chethan K N
ULR NO : CC255920000010863 P