0% found this document useful (0 votes)
445 views30 pages

Shimadzu Spectrophotometer

The document describes several Shimadzu spectrophotometer models including the UV-1280, UV-1900, UV-2600/2700, and UV-3600. The UV-1280 is a lower-cost instrument ideal for routine testing. The UV-1900 has a color touchscreen and high performance features. The UV-2600/2700 are compact with optional integrating spheres. The UV-3600 has three detectors for high sensitivity measurements.

Uploaded by

fadli091
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
445 views30 pages

Shimadzu Spectrophotometer

The document describes several Shimadzu spectrophotometer models including the UV-1280, UV-1900, UV-2600/2700, and UV-3600. The UV-1280 is a lower-cost instrument ideal for routine testing. The UV-1900 has a color touchscreen and high performance features. The UV-2600/2700 are compact with optional integrating spheres. The UV-3600 has three detectors for high sensitivity measurements.

Uploaded by

fadli091
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 30

Introduction Shimadzu

Spectrophotometer UV VIS
Yanwar Pratama
Sales PT DITEK JAYA
2021

1
Line up of Shimadzu
Spectrophotometer UV-Vis

UV-1280
UV-1900

UV-2600/2700
UV-3600
UV-1280

Designed by the leaders in UV -Visible spectroscopy for molecular absorption


quantitative analysis, the UV-1280 Multipurpose UV-Visible
Spectrophotometer offers wavelength scanning from 190-1100nm.
This lower-cost, high-quality instrument is ideal for applications ranging from
routine environmental and food quality testing to life science analyses.

3
Features of UV-1280

1. Minimal Training − Easy to use


A large LCD has been incorporated with easy-to-follow prompts, large fonts,
and graphics to help reduce the time needed to get your results.
2. Wide variety of Measurement mode as standard
One UV-1280 applies to whole UV/Vis analysis.
Photometric, Spectrum, Quantitation, Kinetics, Time Scan, Multiwavelength
Measurement, DNA/Protein, Instrument Validation
3. Multiple Print Utilities
The UV-1280 provides flexible print options with the use of either a thermal
screen copy printer or a variety of PC printers.
4. USB memory
Data are saved in USB memory.
Data can be manipulated by optional MS Excel.
5. Mini Effort to Customize
With over 35 different types of attachments, the UV-1280 can provide all the
tools necessary to handle your specific application.

4
Easy to Operate

⚫ The easy-to-see LCD and buttons enable user-friendly, intuitive


measurement, instrument validation, and printing operations.

5
UV-1900

The UV-1900 is a double-beam UV-Vis Spectrophotometer using


Shimadzu's original LO-RAY-LIGHT™ diffraction grating technology.
In addition to its high optical performance, the UV-1900 features
high resolution, low stray light, high reproducibility, and an
ultra-fast scan function. It also has an easy-to-use interface on a
color touch-screen display. The UV-1900 is designed to meet the
needs of both high performance and usability.
1
Feature 1: Color Touch-Screen Display

Spectrum Mode

Photometric Mode

6
Feature 2: High Performance

● Ultra-Fast Scan
The UV-1900 scan speed is up to 29,000 nm/min

● Low Stray Light and High Photometric Repeatability


Achieved the low stray light (less than 0.5% at 198nm) by adopting
LO-RAY-LIGH® diffraction grating.

● High photometric repeatability


High photometric repeatability (less than ±0.0002 Abs at 0.5Abs and
1.0Abs)
Feature 2: High Performance

● What is the Benefit of Low Stray Light and High Photometric


Repeatability?
Low Stray Light High Photometric Repeatability
With this stray light reduction, accurate With this high photometric repeatability accuracy, variance in the
measurements are possible up to the measurement results is suppressed, enabling more accurate quantitation
vicinity of 2 Abs even in the ultraviolet region, and the detection of low-concentration samples.
high-concentration samples can also be
quantified accurately.

Quantitation of different concentrations Quantitation of different concentrations


of acetic acid (200 nm) of caffeine (273 nm) 10
Feature 3: Multi Language Support

● Support 5 languages (Japanese/English/Chinese/Spanish/Portuguese)


● Language can be changed in General Settings Mode

11
Feature 4: Advanced Regulatory Compliance
● Resolution of 1 nm, capable of meeting the wavelength resolution
required in the European Pharmacopoeia (EP).
● Validation functions enable checks in accordance with EP/USP
(standard).
● Up to 3 validation results of EP/USP can be saved.
● Compliant with ER/ES regulations using UVProbe/LabSolutions
connection kit or LabSolutions UV-Vis

12
UV-2600/2700

The compact UV-2600i/2700i is a universal, research-grade spectrophotometer


that can be used in a wide range of fields, and easily expanded to suit the
measurement objective. By using the optional integrating sphere, the
measurement wavelength range of the UV-2600 can be extended to the near-
infrared region of 1400 nm. The UV-2700 is capable of 8-Abs measurements,
and optimal for measuring low transmittance samples.

1
UV-2600/2700 Features
Instrument design
●Small footprint
✓New optical design achieved
UV-2600/2700
Footprint decreased by28% in
comparison to UV-2450/2550.
✓Dimension
W 450mm x D 600mm x H 230mm 120 mm
●Stream design

60 mm UV-2450/2550

●USB connection
UV-2600/2700 Features
High performance level of optical system
✓ Main monochromator:
Czerny-Turner mount with Lo-Ray-Ligh® diffraction grating Lo-Ray-Ligh®
✓ Pre monochromator: (UV-2700) (Low stray light)
diffraction grating
Littrow mount with Lo-Ray-Ligh® diffraction grating

Low stray light


• UV-2600: < 0.005%T
• UV-2700: < 0.00005%T
UV-2600 Feature

Wide wavelength range


With Dual Detector (PMT & InGaAs)
integrating sphere ISR-2600Plus
the range is extended up to 1400 nm.

220nm~ 1400nm

powder sample
ISR-2600Plus cell & holder
UV-2700 Feature

High Absorbance measurement

8 Abs
(0.000001 %Transmittance)

Measurement 8 Abs is enabled


in UV-2700.
Limit in UV-2550 is 6 Abs.

KMnO4 solution
UV-2700 Feature

High Absorbance measurement (polarizer film)


Rotation film holder can set two film
samples on the same optical axis.
This example is polarizor film
measurement. Two polarizer films
are set and one is rotated.

Cross-Nicol

Open-Nicol

Rotation Film holder (optional accessory)


2-5. UV-2700 Feature (2)

High Absorbance measurement (polarizer film)


Rotation film holder can set two film
samples on the same optical axis.
This example is polarizor film
measurement. Two polarizer films
are set and one is rotated.

Cross-Nicol

Open-Nicol

Rotation Film holder (optional accessory)


Integrating Sphere Attachment

ISR-2600 for UV-2600/2700


ISR-2600Plus for UV-2600

The ISR-2600/2600Plus attachment is designed to be mounted in the


sample compartment of a spectrophotometer to measure diffuse and
specular reflectance of solid samples and transmittance of liquid
samples and films.
UV-3600

UV-3600, the Multi-purpose large-sample compartment and the


Integrating sphere attachment also feature three detector, enabling the
high-sensitivity measurement of solid samples.

1
UV-3600

Highest Sensitivity in Class with Three Detectors

Relationship between Detectors and Measurable Range

1
UV-3600

Highest Sensitivity in Class with Three Detectors

Some spectrophotometers use a PMT


(photomultiplier tube) for the ultraviolet and
visible region and a PbS detector for the
near-infrared region. Neither detector,
however, is very sensitive near the detector-
switchover region. This prevents high-
sensitivity measurement in this range. The
UV-3600i Plus makes it possible to take high-
sensitivity measurements in the switchover
range by using an InGaAs detector.

1
UV-3600

High-Resolution Spectra of Benzene Gas

The spectrum shown was obtained by enclosing benzene gas in a cell with an
optical-path length of 10 mm and performing measurement. The spectral
bandwidth is 0.1 nm. The triplet in the neighborhood of 250 nm (enlarged on
the right) can be clearly observed. This instrument allows high-resolution
spectra to be measured with little noise.
UV-3600

Ultra-Low Stray-Light Level of 0.00005 % Max. (340 nm)


The figure below is a spectrum for aqueous NaNO2 solution, and the figure on the right shows an
enlarged view of the neighborhood of 340 nm. In the figure on the right, the red spectrum is for
aqueous NaNO2 solution and the blue spectrum is the 0 % line obtained when a shutter block is
inserted on the sample-beam side. The UV-3600i Plus achieves an ultra-low stray-light level of less
than 0.00005 % at 340 nm. (A mesh filter is used on the reference-beam side to maintain balance
with the sample-beam side.)
UV-3600

Linearity up to Absorbance Level 6

The figure on the left shows spectra obtained by measuring aqueous


KMnO4 solution at six concentration levels.The figure on the right shows the
calibration curve using peak absorbances in vicinity of 525nm for aqueous
KMnO4 solution, and shows that linearity is maintained up to absorbance level 6.
UV-3600

Linearity up to Absorbance Level 6

The figure on the left shows spectra obtained by measuring aqueous


KMnO4 solution at six concentration levels.The figure on the right shows the
calibration curve using peak absorbances in vicinity of 525nm for aqueous
KMnO4 solution, and shows that linearity is maintained up to absorbance level 6.
Labsolution UV-Vis

Labsolution UV-Vis is control software


that dedicated to Shimadzu
Spectrophotometers. It can control UV-
1900, UV-2600/2700 and UV-3600
Labsolution UV-Vis

Simple Main Window


Labsolution UV-Vis

Four Measurement Modes


Thank you for your attention.

You might also like