EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

This chapter discusses corrosion protection and monitoring techniques. It covers two types of cathodic protection: sacrificial anodes, which use expendable electrodes like zinc to protect structures; and impressed current, which uses an external DC power source. It also discusses measuring corrosion rates through weight loss tests and polarization experiments, and calculating the amount of material needed for sacrificial anode protection using Faraday's law.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
119 views

EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

This chapter discusses corrosion protection and monitoring techniques. It covers two types of cathodic protection: sacrificial anodes, which use expendable electrodes like zinc to protect structures; and impressed current, which uses an external DC power source. It also discusses measuring corrosion rates through weight loss tests and polarization experiments, and calculating the amount of material needed for sacrificial anode protection using Faraday's law.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 11

EN380 Naval Materials Science and Engineering Course Notes, U.S.

Naval Academy

CHAPTER 6

CORROSION PROTECTION AND MONITORING

6.1 Cathodic Protection: Sacrificial Anodes


6.2 Cathodic Protection: Impressed Current
6.3 Measures of Corrosion Rate (Weight Loss and Strength Tests)
6.4 Corrosion Allowance Calculations

As inferred during the previous discussion of the Pourbaix diagram, corrosion may be prevented
by introducing electrical currents from external sources to counteract the normal electrochemical
reaction. There are two basic types of so-called cathodic protection systems, namely, sacrificial
anodes and impressed current. Sacrificial anodes consist of expendable electrodes, usually zinc,
aluminum or magnesium, or their alloys, whose natural potentials provide adequate protective
current to a structure. Impressed current systems are those that employ a direct current (DC)
power source to provide the necessary current.

6.1 Cathodic Protection: Sacrificial Anodes

When iron and copper are attached in a galvanic cell, we have seen that the result is the corrosion
of the iron, with electrons flowing out of the iron (the anode) and into the copper (the cathode).
Suppose that we now place a zinc bar in the cell as illustrated below:

Sacrificial Zinc Anode

In this case, we now find, that because of the potentials involved, that electrons flow out of the
zinc and into both the iron and copper. Thus the zinc corrodes and the iron and copper, which
now both function as cathodes, do not. This is the basis for sacrifical anode protection, namely,
the use of an expendable anode to protect another metal from corrosion. Two examples of this
type of corrosion protection are shown in Figure 28. The first is the protection of an ordinary
hot-water heater with a magnesium anode and the second is the protection of a ship's hull in the
vicinity of the bronze propeller by zinc anodes. Without the protection, the steel hull of the ship
is, of course, subject to galvanic corrosion because of the presence of the bronze material used
for the propeller.

6-1
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Example Sacrificial Anodes

To determine the amount of material needed for sacrificial anode protection of a structure, we
use Faraday's Law together with an estimate of the current density needed for protection
(typically in the range of 10-15 ma/ft2).

Example: If an aluminum alloy is 100% efficient as a sacrificial anode (i.e. it follows Faraday's
Law exactly) determine the number of pounds of aluminum needed to protect a steel structure
with 80 ft2 of surface area in seawater for 18 months. Assume a current density of 10 ma/ft 2 is
needed for current protection.

Solution

W=_CI
From Faraday' Law we have

27
3
C= = 9.33 x 10-5 grams/amp_sec
96,500
where

w = -7.45 x 10-5 grams/sec


Hence

w=(7.35 x 10-5)(2.205)(10-3)(3600)(24)(365)=5.19lb/year
in lbs/yr

For total consumption in 18 months, we must have (for 100% efficiency)

w = (5.19)(1.5) = 7.7 lbs

6-2
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Example: A chemical company advertises aluminum-alloy sacrificial anodes with an average


current output of 1176 amp-hours/lb. Calculate the efficiency.

Solution: From Faraday's Law we have the consumption given as


27
3
C= = 9.33 x 10-5 grams/amp-sec
96,500

hence, the current output is


C-1 = 1.07 x 104 amp-sec/gm
or
C-1 = 1350 amp-hours/lb

The efficiency of the advertised anodes is therefore 1176/1350 = 0.87 or 87%.

Example: An offshore structure has 10,000 ft 2 of submerged area to be protected for 20 years
with aluminum-alloy anodes (85% efficient) weighing 150 lbs each. Determine the number of
anodes required if 15/ma ft2 is needed for protection.
Solution:

Again, from Faraday's Law we have

27
3
C= = 9.33 x 10-5 grams/amp_sec
96,500
and

I = 150 amp

so that

w = -0.014 gm/sec = 973 lbs/year

Hence, w = 973 x 20 = 19463 lbs if the anodes were 100% efficient. Since they are only 85%
efficient, 19463/.85 = 22,900 lbs are required and 22,900/150 = 152.6 or 153 anodes.

6.2 Cathodic Protection: Impressed Current

In an impressed current system of cathodic protection, the current can be supplied from such
sources as storage batteries, rectifiers, or generators depending on convenience and the amount
of current required. The anodes used in an impressed current systems can be expendable, being
made of ordinary steel. Such steel anodes would require periodic replacement, since they are
destroyed at a rate of about 20 pounds/ampere-year by the passage of the protective current. It is
common to use permanent impressed current anodes which are not destroyed or are destroyed
very slowly by the passage of the protective current. These anodes are platinum; platinum
sheathed titanium, tantalum, or niobium. Steel structures exposed to seawater are normally
6-3
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

protected if they are polarized to a potential of -0.85 volts versus a silver/silver-chloride or a


copper/copper-sulfate reference electrode.

A description of such a system follows. Consider again the case of iron and copper attached
together in a galvanic cell, with the iron corroding and the copper protected. Instead of using a
sacrifical anode to supply electrons to the steel and protect it, we use a DC power supply. In this
case, we have the cell described in the figure below.

Impressed Current Cathodic System

By proper choice of the power supply voltage, we can over-ride the potential difference between
the iron and copper and make each act as a cathode (receive electrons) and be protected. In
selecting the proper potential, it must be the same as the open-circuit potential of the local anode.
This means that the voltage is chosen such that current is neither entering or leaving the iron, nor
is it flowing between the local anode and cathode regions on the iron. By use of a standard half-
cell, as in Figure 29, a polarization diagram can also be produced. The open circuit potential and
applied current can be determined in this manner. Thus, the rule for selecting the proper voltage
setting of the power supply is to adjust the power supply until the potential of the iron (and
copper) relative to a standard half-cell is equal to the open circuit potential of the local anode
regions, which was determined experimentally. Some examples of impressed current protection
are shown below .

6-4
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Example: Use the Nernst equation to establish the potential of steel (iron) relative to the
copper/copper-sulfate half-cell needed for protection from corrosion.

Solution: We assume a concentration of 10-3 ions/liter in the electrolyte adjacent to the steel to
indicate essentially negligible corrosion activity. From the Nernst equation, we then have
relative to the hydrogen half-cell,

E = -0.44 +(0.0592/2)Log1010-3

or

E = -0.53 v

The potential of the copper/copper-sulfate half-cell relative to the hydrogen is +0.32V. Hence

E = VFe - VH2 = VFe - VCu + VCu - VH2


or

-0.53 = VFe - VCu + 0.32


or
VFe - VCu = -0.85 v

6.3 Measures of Corrosion Rate

The Galvanic Series gives us information on which metals will corrode when connected with
others in seawater, but it does not tell us anything about the rate of corrosion. Polarization
experiments can give us information on the rate of corrosion of metals connected together or
freely corroding. When time permits, field tests can provide the simplest and most reliable way
to obtain corrosion-rate data.

6-5
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Weight-Loss Tests. These experiments are conveniently made using flat plates, as shown in the
figure below.

Sample for Weight Loss Test

The weight of the plate is given in terms of geometry of the figure above and the specific weight
γ of the material as
2γabh = W
and the rate of weight loss is given by differentiation as

2γ(abh + abh + abh) = W


or with
a b
h = 2 = 2
denoting the corrosion rate, as

2h 2h
2γabh( + + 1) = W
a b
For thin plates, this expression yields
W
h =
2γab
o
Writing A = 2ab = total surface area of plate and W = Δw/Δt, where Δw denotes weight loss in
time Δt, we have
Δw
h =
γAΔt

The corrosion rate may vary with time under various circumstances, but for purposes of
calculation we may generally assume it to be constant. In examining test data, it is usual to
replace Δw and Δt by w and T where w denotes the total weight loss in time T, so that the
equation becomes
W
h =
γAT
These two equations are of course equivalent only if the rate of weight loss is constant.

6-6
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Example. A steel plate of dimensions 3 x 6 x (1/8) inches is known to suffer a weight loss of
0.025 lb when exposed in seawater for 6 months. Determine the corrosion rate.

Solution: We have A = 2(3 x 6) = 36 in2, γ = 0.28 lb/in3, T = 0.5 years and W = 0.025 lbs.
Hence the equation gives

0.025
h = (0.28)(36)(0.5) = 0.005 inchesyear = 5 MPY

If, in place of the thin plate, we have a specimen of arbitrary shape, we may construct a weight-
loss formula similar to that for the flat plate. Consider, in particular, the effect of corrosion on
the cross section shown in the figure below.

During a time Δt, the surface of the solid will move inward an amount _hΔt. If S denotes the
lateral surface area of the solid, the volume loss will be _hΔtS and the weight loss Δw = γ_hΔtS,
where γ denotes the specific weight. Hence, solving for h we have
Δw
h =
γSΔt

If we take S to be the initial lateral surface area of the solid and write W = Δw, T = Δt, we have

W
h =
γST
Because the lateral surface area changes with time, this equation will be only valid only as long
as the lateral area change is small.

6-7
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Example. A cylindrical steel test rod of 0.50 inches in diameter and 2 inches in length is exposed
in seawater for 3 years. The measured weight loss is 0.0165 lbs. Find the corrosion rate.

Solution:

We have γ = 0.28 lb/in3, T = 3 years


and
S = (π x .5 x 2) + (2 x π x 0.252) = 3.53 in2

0.0165
h = (0.28)(3.53)(3) = 0.0055 inchesyear = 5.5 MPY

Note: This is not a particularly good example of our assumption of the total area, S, staying
constant. If one recalls that corrosion occurs through the wetted surface area, it can be shown
that since 12% of the area is at the ends of the cylinder, 12% of the corrosion must have occured
there. The remaining 88% of the corrosion occured through the cylinder walls.

Strength Reduction Test. Instead of using the weight loss test to determine the corrosion rate, we
may use a strength- reduction test. Suppose we have a thin plate with a failure (breaking) force F
applied over area 2ha, as shown in the figure below:

We assume the failure stress Y is the same, regardless of the amount of corrosion so that
F
Y A
= =1
Yo Fo
Ao
where the subscript o denotes initial value. Solving for A/A o, we have
A F
Ao = Fo
now the area A is given by A = 2ah where (neglecting corrosion of the edges as is permissible
6-8
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

for thin plates)


h = ho-ht
hence we have
A 2ah h
= =1- t
Ao 2aho ho
so that _h may be determined as
F
(1- )h
Fo o ΔFho
h= =
T F oT
where T denotes the duration of exposure.

Example: A thin-plate of 1/8 inch thickness is exposed for 6 months in seawater. The initial
yield strength of the plate was 28,000 lbs. After exposure the strength is 25,000 lbs. Determine
the corrosion rate _h.
ΔFho
h =
FoT

(3000) (0.0625inches)
hdot = (28000) (0.5years) = 0.0134inchesyear = 13.4 MPY

Solution:
Suppose that a standard cylindrical tensile specimen is used in place of the flat-plate specimens
in the above scheme. In this case, we have as before
A F
Ao = Fo
But now,
A R hdott
= ( )2 = (1 - )2
Ao Ro Ro
so that
F
1-
Fo
h=( )Ro
T

6-9
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Example: A standard 0.5 inch diameter tensile specimen is found to suffer a 15% loss in
strength when exposed in seawater for 2 years. Determine the rate of corrosion.

F Fo _ F F
Δ = =1- = 0.15
Fo Fo Fo
F
= 0.85
Fo
0.25
h = (1 - .85)( )
2
h = 0.0099inches/year = 9.9MPY

6.4 Corrosion Allowance Calculations

The following examples illustrate engineering calculations associated with corrosion


allowances.

Example: A submerged pipeline is corroding on the outside with a corrosion rate of 15 MPY
and on the inside with a rate of 5 MPY. Find the design wall thickness of the pipe if the design
life is 30 years.
Solution: The inside radius is denoted by r1, and its initial value by r1o. If the corrosion
o
rate is h 1, then
r1 = r1o + h1T
where T = life of the pipe. Similarly, with r2 denoting the outside radius and r2o its initial value.
If the corrosion rate is _h2, then
r2 = r2o - h2T
From a corrosion standpoint we require that r 1 = r2 at T = 30 years. Hence the initial wall
thickness required is
r2o - r1o = (h1 + h2)T
r2o - r1o = (.20)(30) = 0.6inches

From a true design standpoint, we would also need to account for the fact that this pipeline is
going be carrying a fluid at a design flow rate and that it is going to be exposed to both internal
and external pressures. At T = 30 years there will some required wall thickness to withstand this
pressure, p = absolute value of (pexternal - pinternal) and at T = 0, there will be a minimum r1 to allow
for the rated flow at the design pumping pressure. Since we know which material is going to be
used, we also know its shear strength τ. We can now solve for the required wall thickness and
subsequently the outside radius.
pr1
r2 - r1 = + (h1 + h2)T
σ

6 - 10
EN380 Naval Materials Science and Engineering Course Notes, U.S. Naval Academy

Example: A steel cable is to be used as an underwater guide wire in an off shore structure. In
the absence of corrosion, a section area of 1 in 2 is recommended. If tests show the rate of
corrosion at the site and for this material to be 25 MPY, what initial area of cable should be
used for a design life of 20 years.

Solution: With Ro denoting the initial cable radius and R its radius after T years, we have

where _h is the corrosion rate. Now πR2 = 1 and Ro = 0.564 inches.


0.564 = Ro - (0.025)(20)
or
Ro = 1.06 inches, and the required initial area is 3.53 in 2.

6 - 11