This document summarizes a Q&A session for a Hyperflex System Engineer Virtual Enablement training. It includes questions from attendees about Hyperflex configuration topics like node requirements, storage migration, and failover behavior. The trainer provided concise answers to clarify the attendees' understanding of Hyperflex.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as TXT, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
37 views
Asa
This document summarizes a Q&A session for a Hyperflex System Engineer Virtual Enablement training. It includes questions from attendees about Hyperflex configuration topics like node requirements, storage migration, and failover behavior. The trainer provided concise answers to clarify the attendees' understanding of Hyperflex.
Q: #I saw solutions from Cisco that starts with 2 nodes. Is that true?# Priority: #N/A## ##Smail Milak (Guest)#### - 09:44# A: #Correct, HX Edge with 2 Nodes that has to be deployed with Intersight only. It will be covered on this training.### ________________________________________________________________
Q: #How do we migrate data from traditional SAN to hyperflex systems?# Priority: #N/A## ##Smail Milak (Guest)#### - 09:45# A: #While deploying/installing HX you have the option to configure FC or iSCSI storage. It can be configured later as well, on UCSM.### ________________________________________________________________
Q: #Do we have storage only node in Hyperflex?# Priority: #N/A## ##Smail Milak (Guest)#### - 09:45# A: #Coming soon. It's on the roadmap.### ________________________________________________________________
Q: #Is there any option to force hyperflex to a vm, for lab or demonstration purposes?# Priority: #N/A## ##Smail Milak (Guest)#### - 09:50# A: #I'm not following you. Could you rephrase your question?### ________________________________________________________________
Q: #What is we are not buying Fabric Interconnects and directly connecting Hyperflex to ToR switches in HA mode? will that be a supported configuration?# Priority: #N/A## ##Smail Milak (Guest)#### - 09:54# A: #No, standard HX cluster nodes must be directly connected to FI's. Only HX Edge solution doesn't require FI's.### ________________________________________________________________
Q: #Is there eny option to emulate an environment to excerices or test the hyperflex?# Priority: #N/A## ##Smail Milak (Guest)#### - 09:55# A: #Only dCloud for now. They are using a simulator for labs.### ________________________________________________________________
Q: #LACP is required for Network Connection? # Priority: #N/A## ##Smail Milak (Guest)#### - 09:55# A: #Between FI's and Upstream? It doesn't matter but LACP is always recommended.### ________________________________________________________________
Q: #Can ACI be used on the Nexus SWs, or is it only NXOS?# Priority: #N/A## ##Smail Milak (Guest)#### - 09:59# A: #ACI is fully supported. It will be covered on this course. Just connect FI's to leaf switches.### ________________________________________________________________
Q: #Why do I need the top of rack switches and the FIs? First we said that Cisco HX includes network what others do not and then we need another networking device. That is something that I do not understand.# Priority: #N/A## ##Smail Milak (Guest)#### - 10:00# A: #With ToR we mean upstream switches that connect to the rest of the network. For example your DNS, NTP, DHCP servers and of course the internet for Guest VMs. All HCI solutions require upstream switches.### ________________________________________________________________
Q: #If there is a an FI Failure... What is the impact? # Priority: #N/A## ##Smail Milak (Guest)#### - 10:01# A: #We have always two FI's, so no downtime in case of one ONE FI failure.### ________________________________________________________________
Q: #Do we have packet drops ?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:18# A: #Maybe for a brief time while the traffic is switching to subordianate FI### ________________________________________________________________
Q: #Will it affect the storage performance?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:29# A: #Slightly, because it will be switched over the port-channel port to the upstream switch instead of locally switching.### ________________________________________________________________
Q: #Installation VM comes along with HyperFlex from factory or should be pushed after it reaches customer site?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:30# A: #You have to download it from software.cisco.com and deploy it on your laptop (VMware workstation) , or any other ESXi.## ##Smail Milak (Guest)#### - 10:30# A: #But you can use Intersight that is hosted by Cisco for HX installations as well.### ________________________________________________________________
Q: #Both FI are active? or they work as Active / Passive?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:31# A: #Both are active, but FI 1 will be used e.g. managemnet, vmtion and FI 2 for storage traffic. This will be covered as well.### ________________________________________________________________
Q: #My understanding is that I need a specific disks for HX. Meaning that all disks must be of the same type. Is that Correct?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:32# A: #Correct, same type and size of disk inside every HX Converged node. Cisco is working on a solution to have heterogeneous drive support. Maybe end of 2020.### ________________________________________________________________
Q: #While increasing hard disk capacity by adding an additional server, would it required to purchase CPU license for virtualization?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:32# A: #This is a requirement of VMWare, so yes. Even in case of compute only nodes.### ________________________________________________________________
Q: #why can't we use FI as our upstream switches as well?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:33# A: #You can do it. But you always have another layer in your network, right. Also upstream switches are needed for HA.### ________________________________________________________________
Q: #That means if I have 3 nodes and I need 1 more disk then I actually add 3 disks, fore each node one, right?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:34# A: #Correct. You have to add one drive on each HX Converged node. Don't forget that 6 drives is minimum in case of Standard CLuster, 3 drives in case of HX Edve.### ________________________________________________________________
Q: #Can we buy just any disk or are disks vendor-locked, so we can buy it only from Cisco?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:35# A: #Only the ones that is Cisco selling on CCW.### ________________________________________________________________ ###Suresh (Guest)# (#[email protected]#)# - 10:20# Q: #If a cluster having 20 nodes with existing free slots for additional hard disk expansion, then we must increase equal capacity + Qty across the cluster.. Is that right?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:35# A: #That is correct...for now we have this requirement. heterogeneous drive support is coming end of 2020, hopefully.### ________________________________________________________________
Q: #How does the native replication for the 2nd DC work?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:41# A: #You have HX both sites and you will establish connectivity first, then create a network for nat replication and finally protect the VM's. They will be copied (first all data, later only increments). You can then protect your VM's on 2nd DC and replicate## ##Smail Milak (Guest)#### - 10:42# A: #replicate to 1st DC.### ________________________________________________________________
Q: #how many maximum nodes can be supported / added to Edge deployment clusters?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:42# A: #Expansion of HX Edge is not supported. We will probably get support for 2 and 3 nodes expansion, but max will be 4.### ________________________________________________________________
Q: #Is that HyperFlex Edge can be upgraded to Standard ESXi to add more than 4 nodes?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:43# A: #No, 4 nodes is the limit. Everything above is Standard HX cluster with FI's. ### ________________________________________________________________
Q: #will the slides of the course be sent by email?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:44# A: #You have the Student Learning Guide with the same slides plus explanation. Slides in PDF or PPT can't be shared per Cisco policy.### ________________________________________________________________
Q: #ok...and Q&A ?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:46# A: #I can share that with you, but I think that you can save it as well on exit (end of the training). If you don't have that option let me know and I will send it to you. ### ________________________________________________________________
Q: #Standard ESXi - 3 to 64 nodes (32 + 32... This is something not clear and need more clarity here)# Priority: #N/A## ##Smail Milak (Guest)#### - 10:47# A: #32 converged nodes and 32 compute-only nodes. Only with that combo you can have 64 nodes in one ESXi based cluster.### ________________________________________________________________
Q: #That means, Hyperflex not having an option to expand only storage capacity by adding a node without CPU licenses. Is that right?# Priority: #N/A## ##Smail Milak (Guest)#### - 10:51# A: #A storage only node is coming soon, but for now you have to use regular converged nodes to expand storage or simply add more drives.### ________________________________________________________________
Q: #Cisco WOM and Intersight can be sold to exisiting vblock & flexpod customers too right? Not necessary to be with Hyperflex only.. Correct me if i am wrong please# Priority: #N/A## ##Smail Milak (Guest)#### - 10:52# A: #Correct. CWOM works with many vendors, EMC, Pure storage, IBM...### ________________________________________________________________
Q: #could we get the slides at least please ?# Priority: #N/A## ##Smail Milak (Guest)#### - 11:04# A: #Sorry, Cisco doesn't share that.### ________________________________________________________________
Q: #so it could help with our study# Priority: #N/A## ##Smail Milak (Guest)#### - 11:04# A: #This question has been answered verbally.### ________________________________________________________________
Q: #please declare certification & advise if there is prerequisit from cisico to get it# Priority: #N/A## ##Veselin Ilic (Guest)#### - 10:58# A: #I will answer this question publicly after the break.## ##Smail Milak (Guest)#### - 11:07# A: #Exam #700-905. No prerequisit. You can pass the exam easily after this course.### ________________________________________________________________
Q: #Can we add compute only node (UCS) to hyperflex cluster.. if Yes is there any limitation.? # Priority: #N/A## ##Veselin Ilic (Guest)#### - 11:00# A: #Yes, hardware compatibility is limitation, type of cluster, etc. We will cover it in details later.### ________________________________________________________________
Q: #Can we turn off Installer VM once configuration is completed?# Priority: #N/A## ##Veselin Ilic (Guest)#### - 11:00# A: #Yes### ________________________________________________________________
Q: #Hyperflex already tested with Vsphere 7.X and when can we expect those validated system to public?# Priority: #N/A## ##Smail Milak (Guest)#### - 11:18# A: #No information about that yet, but I assume that it will be availabe with the next release.### ________________________________________________________________
Q: #There is a yellow box that hides some of the content# Priority: #N/A## ##Smail Milak (Guest)#### - 11:23# A: #Fixed### ________________________________________________________________ ###Leif Eric Hintzsche (Cisco)# (#[email protected]#)# - 11:24# Q: #What is the default network configuration in CIMC the when the HX is shipped?# Priority: #N/A## ##Smail Milak (Guest)#### - 11:26# A: #All blank. You will configure CICM with the Installer.### ________________________________________________________________
Q: #Why cloud not the FI handle the link failure on L1/L2 Interconnect link?# Priority: #N/A## ##Smail Milak (Guest)#### - 11:33# A: #This would be a split brain scenario if both links are down. That's why we have two of them.### ________________________________________________________________
Q: #However, in order to use the installer, I need to have a network connection first, right?# Priority: #N/A## ##Smail Milak (Guest)#### - 11:34# A: #Yes, the installer must be able to reach UCSM, vCenter. Basically all HX networks that are used and will be used for the deployment.### ________________________________________________________________
Q: #How do we expand this S-Series Storage capacity? will it support cascading or must be a seperate hardware?# Priority: #N/A## ##Smail Milak (Guest)#### - 11:48# A: #S Series is not part of HX. You will use S Series for backup.### ________________________________________________________________
Q: #I understand that S Series is for backup. Question is, S Series system allow the hardware to expand using daisy chain or not.. Any feedback is highly appreciated# Priority: #N/A## ##Smail Milak (Guest)#### - 12:26# A: #Sorry, I don't have an answer to that question.### ________________________________________________________________
Q: #can we get link for study guide and exam prep guides# Priority: #N/A## ##Smail Milak (Guest)#### - 13:22# A: #Please send me an e-mail to [email protected] with full name.### ________________________________________________________________
Q: #Is the vpshere 7.0 supported in hyperflex environment?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:25# A: #6.7 U3 is the latest that is supported. 7.0 will be supported soon.### ________________________________________________________________
Q: #Does it work with other Hypervisors different from ESXi?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:24# A: #Hyper-V and KVM as part of HX Application Platform for know.### ________________________________________________________________
Q: #Student Guide for this training , not exam is link availbe or only lab guide is there# Priority: #N/A## ##Smail Milak (Guest)#### - 13:36# A: #That is correct. The student guide is available only on learningspace. You will get an e-mail from Cisco about that.### ________________________________________________________________
Q: #What happens if we delete the HyperFlex snapshots? where the vm and application data will be sitting on that moment? # Priority: #N/A## ##Smail Milak (Guest)#### - 13:36# A: #The VM will stay on the same location if you delete the HX snapshot.### ________________________________________________________________
Q: #What kind of logging information do I get from the CVMs?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:40# A: #You will configure Syslog on HX Connect, which is the administration tool of HX.### ________________________________________________________________
Q: #What if I need to troubleshoot during the initial installation prozess?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:46# A: #You have logs on the installer VM that yu can generate and take a look. Same logs can be sent to TAC### ________________________________________________________________
Q: #where does iovisor run? ESXI or cvm or on the guest VM# Priority: #N/A## ##Smail Milak (Guest)#### - 13:46# A: #on every ESXi. In case of Hyper-V on CVM### ________________________________________________________________
Q: #Does it use the same sharding as used in ACI?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:56# A: #Yes, it's similar to shards. Three copies, evenly distributed across the whole StorFS filesystem.### ________________________________________________________________
Q: #What is the default Replication factor? or it need to be selected during installation?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:53# A: #no def but RF3 is recommended for Standard Cluster, especially for scalability and fault tolerance. ## ##Smail Milak (Guest)#### - 13:53# A: #You need at least RF3 and 5 nodes for 2 Node failure tolerance### ________________________________________________________________
Q: #RF=3 -> would it support 2 server node failure?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:53# A: #Yes, but with 5+ nodes.### ________________________________________________________________
Q: #When you distribute the data accross multiple clusters, can you seperate the data of different tenants?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:57# A: #We can't distrubute data across multiple clusters. Only one HX cluster. You can have multiple HX clusters but they are independed (storage wise) or each other. ## ##Smail Milak (Guest)#### - 13:57# A: #You can use the same vCenter, though.### ________________________________________________________________
Q: #Is that also possible for Edge Clusters?# Priority: #N/A## ##Smail Milak (Guest)#### - 13:58# A: #What exactly? The fault tolerance? With HX Edge 2, 3 or 4 node only one node can fail at a time becuase of the quorom where we need more than 50% of nodes running.### ________________________________________________________________
Q: #in an scenario with 3 nodes cluster, and 1 node alive, with RF=3, is the data still available??# Priority: #N/A## ##Smail Milak (Guest)#### - 14:04# A: #Cluster will shut down in order to protect data corruption.### ________________________________________________________________ ###victor (Guest)# (#[email protected]#)# - 14:04# Q: #i mean 2 nodes down at same time, in that scenario, wouldnt be the data still available? you should have at least one copy of your chunks data, right?# Priority: #N/A## ##Smail Milak (Guest)#### - 14:05# A: #Yes, no data loss (well maybe a tiny amount that could not be stored on time). Cluster will shut down to protect the data. Only with quorum the cluster can be running.### ________________________________________________________________
Q: #when using HX sizer, is the total usable disk result of the toll will be after using RF3 ?# Priority: #N/A## ##Smail Milak (Guest)#### - 14:10# A: #Correct. Use "I have a fixed config" to find out more about that. Ask me if you're stuck.### ________________________________________________________________
Q: #can that behaviour changed in order to save data? data availability in some cases is more important # Priority: #N/A## ##Smail Milak (Guest)#### - 14:11# A: #No, you can make it only more strict :)### ________________________________________________________________
Q: #when using HX sizer, is the total usable disk result of the tool will be after using RF3 ?# Priority: #N/A## ##Smail Milak (Guest)#### - 14:11# A: #Correct. Use "I have a fixed config" to find out more about that. Ask me if you're stuck.### ________________________________________________________________
Q: #The hypervisor is installed in house keeping drive?# Priority: #N/A## ##Smail Milak (Guest)#### - 14:30# A: #No, boot drive, same for CVM. Housekeeping drive will store CVM data like logs, cleaner etc.### ________________________________________________________________
Q: #Or only the CVM is present in housekeeping drive# Priority: #N/A## ##Smail Milak (Guest)#### - 14:30# A: #Not even CVM (booted from boot drive)## ##Smail Milak (Guest)#### - 14:31# A: #Cisco is planning use two M.2 in RAID with two partitions, one for booting and one for housekeeping, but no dates yet.### ________________________________________________________________
Q: #Write cache level 2 and 3 has the same data as level 1 cache?dont know if my question makes sense though# Priority: #N/A## ##Smail Milak (Guest)#### - 14:38# A: #Same data. It's actually primary, secondary, tertiary. The CVM will copy the data to all three, but on different nodes. The primary copy will be stored where the CVM (that was selected for that data) is running.### ________________________________________________________________
Q: #in the documentation we can read that in allflash, read is primary copy if possible# Priority: #N/A## ##Smail Milak (Guest)#### - 14:39# A: #Correct. I had this question maybe 2 times (yours included). AF reads from the primary## ##Smail Milak (Guest)#### - 14:40# A: #Hybrid reads from all### ________________________________________________________________
Q: #but not clear what primary copy means# Priority: #N/A## ##Smail Milak (Guest)#### - 14:40# A: #Primary means that it's stored where the CVM is runnig. On destaging only the primary copy will copied to the capacity tier.### ________________________________________________________________
Q: #ok, primary copy is stated by the CVM "responsible" of that block then# Priority: #N/A## ##Smail Milak (Guest)#### - 14:41# A: #Correct.### ________________________________________________________________
Q: #Thanks Smail:)# Priority: #N/A## ##Smail Milak (Guest)#### - 14:48# A: #You are welcome Wanjira.### ________________________________________________________________ ###Wanjira Anjimbi (Cisco)# (#[email protected]#)# - 14:48# Q: #Smail,if all flash is reading from the primary copy only isnt that some sort of locality ?# Priority: #N/A## ##Smail Milak (Guest)#### - 14:49# A: #No, because the guest CVM could be running on Node 1 but the primary copy is on node 8.## ##Smail Milak (Guest)#### - 14:49# A: #I mean guest VM, not Guest CVM.### ________________________________________________________________
Q: #understood thanks!# Priority: #N/A## ##Smail Milak (Guest)#### - 14:52# A: #This question has been answered verbally.## ##Smail Milak (Guest)#### - 15:10# A: #Depends on you, just be aware that in case of stretched L2 link failure you will not be able to connect to the FI on the other site.### ________________________________________________________________
Q: #In Stretched cluster, the FI's OoB should be streched or can they have vlan dedicated to the single site?# Priority: #N/A## ##Smail Milak (Guest)#### - 15:12# A: #This depends on your. You can have it both, it's not imporatnt for HX operations but for site failure.### ________________________________________________________________
Q: #ok so it is not mandatory to have the stretched OoB for the correct functionality of the stretched HX cluster, right?# Priority: #N/A## ##Smail Milak (Guest)#### - 15:12# A: #Correct.### ________________________________________________________________
Q: #ok...but if OoB are routed L3, does it work the same? # Priority: #N/A## ##Smail Milak (Guest)#### - 15:15# A: #Well, yes. The link between site is L2 and you can route it over that, or use any other way to connect to your FI OoB (Router with IPSec over Internet for example).### ________________________________________________________________
Q: #sorry maybe I dont understand at well, The M4 cluster can expand with M5, the M5 can not expand with M4, am I right?# Priority: #N/A## ##Smail Milak (Guest)#### - 15:26# A: #That is correct. You can have a M4 based cluster and expand it with M5, but not vice versa.### ________________________________________________________________
Q: #Please clarify on the specific use of housekeeping/system drives# Priority: #N/A## ##Smail Milak (Guest)#### - 15:45# A: #This question has been answered verbally.### ________________________________________________________________
Q: #I have requirement to lift and and shift Nutanix box and connect to cisco ACI, Is it viable?# Priority: #N/A## ##Smail Milak (Guest)#### - 15:59# A: #This is a HX course, not Nutanix :). You may connect it to ACI, but I don't know any details. ### ________________________________________________________________
Q: #What happens if my license expires?# Priority: #N/A## ##Smail Milak (Guest)#### - 16:00# A: #It will keep running, no worries. Your Cisco account manager will be notified and Cisco TAC will ask you about that when you open a ticket but they will still help.### ________________________________________________________________
Q: #Your share is not seen # Priority: #N/A## ##Smail Milak (Guest)#### - 16:17# A: #This question has been answered verbally.### ________________________________________________________________
Q: #These DXDP standard & enterprise licenses are vmware licenses right?# Priority: #N/A## ##Smail Milak (Guest)#### - 16:24# A: #No, VMware licenses are seperate. For VMware HX is just any other cluster (CPU, memory etc).### ________________________________________________________________
Q: #can i hav a copy of daily session Q&A # Priority: #N/A## ##Smail Milak (Guest)#### - 16:24# A: #Yes, while existing you will be asked if you want to save the Webex files. If you don't get this option let me know and I will send it to you.### ________________________________________________________________
Q: #If hyperFlex cluster is not yet ready, where do we setup the Installer VM and a vCenter Server?# Priority: #N/A## ##Smail Milak (Guest)#### - 16:25# A: #Installer VM can run on your PC (VMWare workstation for example). vCenter can be added later as nested vCenter (running on top of HX).### ________________________________________________________________
Q: #Must I update before I start the installation process? What happens if I stick with the versions that come out of the box?# Priority: #N/A## ##Smail Milak (Guest)#### - 16:25# A: #You will always upgrade ESXi to the desired version but you can also order it with the latest version available.## ##Smail Milak (Guest)#### - 16:26# A: #ESXi will be installed in factory for you.### ________________________________________________________________
Q: #What is the pattern of the release numbers? How do I distinquish major, minor, BF and HF versions?# Priority: #N/A## ##Smail Milak (Guest)#### - 16:30# A: #You will see a star on softwar.cisco.com. It's e.g 4.0 and 4.0.2a, b, c, d, e etc. After that 4.5a, b, c, d etc.### ________________________________________________________________
Q: #are distributed vswitches supported, such as using NSX? # Priority: #N/A## ##Smail Milak (Guest)#### - 17:02# A: #Yes, this will work just fine but Cisco doesn't have any design guides about that yet.### ________________________________________________________________
Q: #can you install hyperflex using a single instance of vCenter and then join it to the main vCenter, eg if you are integrating the HyperFlex for a customer can you install it using your onsite vCenter then ship it t o customer site and join it to their vCent# Priority: #N/A## ##Smail Milak (Guest)#### - 17:00# A: #Yes, you can always change vCenters by reregistering it.## ##Smail Milak (Guest)#### - 17:01# A: #This will be covered here### ________________________________________________________________
Q: #Hi, I only have oppurtinity to join now . Will power point be shared ? # Priority: #N/A## ##Smail Milak (Guest)#### - 16:59# A: #Hi, only the Student Learning Guide is shared.### ________________________________________________________________
Q: #What is the minimum NTP stratum requirement?# Priority: #N/A## ##Smail Milak (Guest)#### - 17:00# A: #I don't know that exactly but it can be configured later on CVM (linux cmd).### ________________________________________________________________
Q: #vcenter could be nested or needs to be standalone?# Priority: #N/A## ##Smail Milak (Guest)#### - 17:02# A: #Any of the two will work.### ________________________________________________________________
Q: #Do we need send you an email for run labs ?# Priority: #N/A## ##Smail Milak (Guest)#### - 17:19# A: #This question has been answered verbally.### ________________________________________________________________
Q: #not now...but between 3 or 4 days...# Priority: #N/A## ##Smail Milak (Guest)#### - 17:19# A: #No need for that. You will schedule it by yourself. Use the tutorial that I have shared### ________________________________________________________________
Q: #so this means labs is on our own time seperatley? wont be doing together during sessions? # Priority: #N/A## ##Smail Milak (Guest)#### - 17:21# A: #Correct. Do it when ever you want. This is a large class (150 attendees), that's why we have to do it again.### ________________________________________________________________
Q: #"Please note, The webinar will last from 10.00 to 14.00 and will Cover mainly HyperFlex Positioning vs others !!!" 17th june # Priority: #N/A## ##Smail Milak (Guest)#### - 17:22# A: #I will let them know that. ### ________________________________________________________________
Q: #this is part of our workshop? an email sent by cisco team - vitual delivery # Priority: #N/A## ##Smail Milak (Guest)#### - 17:22# A: #This question has been answered verbally.### ________________________________________________________________
Q: #lab after 1 hr?# Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:30# A: #No, you can start Lab when you want, we will be with you for next 1 hour### ________________________________________________________________
Q: #I've just joined one hour ago could please tell wich topics talked today? # Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:31# A: #Last topic that we have covered is Installation of HX ESXi based cluster### ________________________________________________________________
Q: #Thank alot for this addional efforts for Scheduling lab session.. as we know today training time is already over.# Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:31# A: #You are welcome### ________________________________________________________________
Q: #Student Guide for this training , not exam is link availbe or only lab guide is there# Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:33# A: #Lab guide link is now shared.### ________________________________________________________________
Q: #How many LAZ can we have in a cluster.? One zone can have maximum of how many Host?# Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:36# A: #Theoretically you can have 16, but max 13 is supported per Administration guide.### ________________________________________________________________
Q: #How many LAZ can we have in a cluster.? One zone can have maximum of how many Host?# Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:37# A: #Answered in previous question.### ________________________________________________________________
Q: #How many LAZ can we make in a cluster ?.. How many host we can add in a one LAZ. what are the limitations# Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:38# A: #Theoretically you can have 16, but max 13 is supported per Administration guide.### ________________________________________________________________
Q: #are we done for today , wasnt here for 15 min but i see all connected# Priority: #N/A## ##Veselin Ilic (Guest)#### - 17:45# A: #For theory part, Yes. If you want to start with the Lab, you can do so.### ________________________________________________________________