0% found this document useful (0 votes)
678 views

Design Modification Sheet Cab Redanduncy

This document contains a diagram of the cab redundancy system for a vehicle. It shows the various components involved like compressors, reservoirs, switches, and contactors. The components are connected by lines and numbered pins. It provides information on the component names, numbers, and functions within the system.

Uploaded by

amit guin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
678 views

Design Modification Sheet Cab Redanduncy

This document contains a diagram of the cab redundancy system for a vehicle. It shows the various components involved like compressors, reservoirs, switches, and contactors. The components are connected by lines and numbered pins. It provides information on the component names, numbers, and functions within the system.

Uploaded by

amit guin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 27

CAB REDUNDANCY

Contactor Aux. Compressor Low Contactor Brake Contactor


06E
Switch
Main Compressor Main Compressor 1 Main Reservoir Main Compressor 2 Feed Pipe Aux. Compressor Position Function Description Pin layout

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
47.2 Contactor Main Compressor 25B
47.2A Snubber ckt. to item no. 47.2
A

04C 06 04E 01 04E 03 04C 10 04E 07 04E 05 06A 09 04C 11 48 Aux. Compressor Unit (17)
48.2 Contactor Aux. Compressor
123 Blocking Diodes 26C
172 Spring loaded switch Compressor "BLCP"
2111A

2069
3090
172.2 Pressure switch Main compressor (35)
172.3 Pressure switch Main compressor (36)
172.4 Pressure switch Aux. compressor (26)
B

260 Control Electr Pneu. Equipment (45)

4202
260.B Connector Ctrl Electr Pneu. Equ. (172) 27A
2111A

260.B

4201

3101

3101
2111A

3101

3101
SJ 260 260.D Connector Ctrl Electr Pneu. Equ. (172) 27A
269.4 Pressure switch Low Main resorvoir(37)
OFF A1 OFF B1 269.42Pressure switch Brake feed pipe (34)
Q3 172.2 Q1 172.2 Q1 Q1 269.4 411 Ctnral Electronics 1 (CEL 1)
C

AUTO AUTO 172/1 172.3


P10 P10 411.LJ Connector 28B
P6.4

4204

4203
MAN MAN P10
A2 B2 411.OA Connector 28B

3035A
Q4 < 8.0 Q2 < 8.0
Q2 < 7.5 Q2 < 5.6 411.OJ Connector 28B
411.LA Connector 28B
SJ 411.LD Connector 28B
3034A

3035A

260.D
412 Ctnral Electronics 2 (CEL 2)

3036

3090

3025
3038

3044
D

412.JJ Connector 28E


412.OA Connector 28E
Q1 269.42 Q1 412.QD Connector 28E
411.OA 411.OA 411.LJ 411.OJ 412.QD 412.QD 412.QD 412.QJ 412.JJ 172.4
4 411 12 411 9 411 2 411 4 412 2 412 11 412 3 412 4 412 412.QJ Connector 28E
P5.6 P6.0
STB1 HBB1 HBB2 STB2
AMSB_0202- AMSB_0201- AMSB_0202- Q2 < 5.0 Q2 < 5.2
AMSB_0201-
B B BContCompr1 BContCompr1 B B B BContCompr2
E

BContCompr2

3045

3018
Z SK
HBB1 HBB1 HBB2 HBB2 HBB2
AMSB_0101- AMSB_0101- AMSB_0102- AMSB_0102- AMSB_0102-
LSwComprOff LSwComprDir MPrSw8bar MPrSw7.5bar MPrSwLowMR
9 411.LJ 2 411.OJ 10 412.QJ 12 412.JJ
SK 260.B
3115
3114
F

3116

3118
04C 09 1 3
7 9
04C 02 123/8 123/8
123/5 123/5 2 4
8
2068
10

3037B
CAB REDUNDANCY

3037B
G

3037A

3037A

+1 FOR
2111B

48.2
WAG-9/ WAP-7/ WAP-5
-2

A1 B1
H

OFF OFF
3027

AUTO AUTO 172/2


MAN MAN
A2 B2 Dy.CEE/D&D

3043

3026
3035B

3035B
3034B

3034B

Z 48
I

412.QD
411.LA 412.OA 412.OA 411.LD 47.2A/2
12 411 4 412 12 412 12 411 12 412
1+ 2+ 47.2A/1 1+ 2+
M 3037B
3037A

B B B B A1 B A1 48.2
A1
47.2/2 DT
J

47.2/1
STB1 HBB2 HBB2 STB1 A2 A2 HBB2 A2
ZZ
AMSB_0102- AMSB_0101- AMSB_0101- AMSB_0102- AMSB_0102-
2050
2050

LSwComprOff LSwComprOff LSwComprDir LSwComprDir MprSwBkFP


4- 3- 4- 3- CHITTARANJAN LOCOMOTIVE WORKS
Chittaranjan
CENTRE FOR DESIGN AND DEVELPOMENT
K

04B 01 06E
SSE/D&D AEE/D&D
Actual BE Electric
06H
Pressure Transducer Automatic Brake Direct Brake Isolation Valves
Brake Pipe Pressure Isolation Automatic Train Brake Position Function Description Pin layout
BE Feedback Cut Out Loco Cab. 1 Cab. 2

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
06A 06 04C 06 04C 09 260 Control Electronics Pneumatic Equip. (45)
A

260.A Connector Control Electric Pneum. Equip. (173) 27A


260.B Connector Control Electric Pneum. Equip. (172) 27A
05A 10 11A 11

3051
260.C Connector Control Electric Pneum. Equip. (173) 27A
412.OJ 06B 02
269.7 260.D Connector Control Electric Pneum. Equip. (172) 27A
412 14 412 06C 09 261 Drive / Interlock Relay P.C.B.
FLG2 HBB2 06D 06 269 Pressure Transducer Automatic Brake Pipe (45)
AMSB_0201- AMSB_0201- 269.7 Pressure Transducer BE Feedback (EBC5) (55)
P 06I 04
269.7F Connector Pressure Transducer BE Feedback (55)
WPnBEdem BEPAutoBkOut
B

270.1 EP Valve Automatic Brake Loco Cut Out (52)


270.1A Snubber Circuit To Item No. 270.1 (52)
I A 270.2 EP Valve Isolation Direct Brake Handle (112)
270.2A Snubber Circuit To Iten No. 270.2
270.5 EP Valve Isolation Automatic Train Brake
A B D F 269.7F 9 5 QE 7 270.5A Snubber Circit To Item No. 270.5
412.EC 412.OJ 411 Central Electronics 1 (CEL 1)
C

411.JD Connector 28D


412 Central Electronics 2 (CEL 2)
412.EC Connector 28D
412.OJ Connector 28E

2111A

2111B
412.QA Connector 28E
3082
3083
3084
3085

3014
3015
3011

3016

2054
D

260.A 260.B
D B C A E R P L A B 260
E

269
+ 15V
- 15V

P
COELOK
I
F

3068B
SM N M L L A B
3068A

260.B 260.A 260.D


261
3012

65 64
67 3601 CAB REDUNDANCY
G

63 62 FOR
1 + 2 + 270.1A 1+ 2+ 1+ 2+ 1+ 2+ WAG-9/ WAP-7/ WAP-5
270.2A/1 270.2A/2 270.5A
3063A

3063B
3012

3601
A1 A1 A1 A1
3010
H

3009

3011

EP 270.1 EP 270.2/1 EP 270.2/2 EP 270.5


A2 A2 A2 A2
3008

3008

2054

2054

2054

2054

2054
Dy.CEE/D&D

4- 3- 4- 3- 4- 3- 4- 3-
I

2054

2054
411.JD 412.QA 412.EC 260.D
12 411 10 412 6 1 412 P R
260
J

B B A

STB2 HBB2 FLG2


AMSB_0102- AMSB_0102- AMSB_0101- CHITTARANJAN LOCOMOTIVE WORKS
MBrakeElecOK MBrakeElecOK XPrAutoBkLn Chittaranjan
G CENTRE FOR DESIGN AND DEVELPOMENT
2050

260.B
K

04B 01 SSE/D&D AEE/D&D 06H


08A
Safety Relay Power Supply Contactor Control Detection Of Key
Control Electronics ON Cab Circuit ON Switch Position Position Function Description Pin layout

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 123 Bloking Diods 26C


125 Cab Activating Key Switch BL 26B
A

04C 06 04C 09 04C 01 04E 03 04E 01 04C 06 126 Contactor Control Circuit ON 25C
126.5 Relay Control Electronics OFF 25C

2111B
126.5ASnubber Circuit To Item 126.5

2067

2111A
2111A

126.6 Safty Relay Control Electronics ON 25C


126.7 Contractor Power Supply Cab. 25C

4201
4201
4201
4202
126.7ASnubber Circuit To Item No. 126.7
1 1 411 Central Electronics 1 (CEL 1)
B

D D
87 3 411.JA Connector 28B
0 125/1 0 125/2 D 125/1
411.LA Connector 28B
C C 9 9 126.6 0 411.LG Connector 28B
D D
2 2 411.OA Connector 28B
0 125/1 0 125/2 C
88 4
411.QJ Connector 28B

4243
C C
2500B
412 Ctnral Electronics 2 (CEL 2)
2500A

10 10
C

4242A
412.JA Connector 28E
411.QJ 411.JA
10 411 11 411
HBB1
AMSB_0202- B
BContSelfH
D

2503B
STB1

2503A
AMSB_0101-
2500B

2500B
2500A

2500A

LActkSwC
411.JA 411.OA 412.JA 412.OA 3
3 411 9 411 3 412 9 412 411.QJ 411.LA 411.LG 411.LG
11 411 2 411 19 411
E

B B B B STB1 STB1
B AMSB_0202- AMSB_0202-
BContSelfH BRelMCEOff 04C 09
STB1 HBB1 STB2 HBB2

2503B
STB1
2503A

AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101-

2111B
LActkSwD LActkSwD LActkSwD LActkSwD AMSB_0102-
F

MRelMCEOn

2503B
2503A
14 7
2500B

411.LG 411.LG
2500A

75 75

2506

2066
D 3
126.7/2 125/2
126.7/1
0 CAB REDUNDANCY
123/1 123/1 123/5 123/1 123/7
G

76 76 C
123/1 123/1 5 7 5 9 9 4 FOR
1 3 WAG-9/ WAP-7/ WAP-5

4242B
6 8 6 10 10
412.JA
2505

2505

2505
2 4
11 412
H

2504B

2501
2504A

2070
13 B

126.5 Dy.CEE/D&D
21 STB2
14 AMSB_0101-
126.5
2501

LActkSwC
I

22
126.7A/1 126.7A/2
1+ 2+ 1+ 2+ 1+ 2+ 126.5A
2504A

2508
2504B

2070
126.7/1 126.7/2 126.5
A1 A1 A1 A1 A1
J

126.6 DT 126
A2 A2 A2 A2 A2
CHITTARANJAN LOCOMOTIVE WORKS
2050
2050

2050

Chittaranjan
SSE/D&D
2050

CENTRE FOR DESIGN AND DEVELPOMENT


4- 3- 4- 3-
K

2050 08A
04B 01 AEE/D&D
08C
Angle
Reverser Transmitter Throttle Auxiliary Contacts Position Function Description Pin layout

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 140 Switch Travel Direction(Reverser)


150 Throttle Tractive Effort/Regenerative Brake
A

04C 06
150.1 Angle Transmitter Drive Controller
2111A 150.A/1 150.A Connertor
1 150.B Connector
411 Central Electronics 1(CEL-1)
411.EA Connector 28A
411.OD Connector 28A
B

411.JD Connector 28A


411.JA Connector 28A

TEMax TEMax TEMax TEMax


C

2/3TE 2/3TE 2/3TE 2/3TE

F 1 F 3 F 5 F 7 140/1 1/3TE 1 1/3TE 3 1/3TE 5 1/3TE 150/1


7

0 0 0 0 0 0 0 0
D

R 2 R 4 R 6 R 8 1/3BE 2 1/3BE 4 1/3BE 6 1/3BE 8


2+ 4+ -1
2/3BE 2/3BE 2/3BE 2/3BE

BEMax BEMax BEMax BEMax


E

3 5 9 QE
2 3 4 5 6 7 8 9
150.A/1
F

2531A
2530A
2529A
2528A

2520A

2521A

2522A

2523A
2524A

2525A

2526A

2527A

CAB REDUNDANCY
FOR
G

WAG-9/ WAP-7/ WAP-5

2521A

2521A

2523A

2523A
2520A

2520A

2522A

2522A
411.JD 411.OD 411.JD 411.QD 411.EA
H

9 411 9 411 2 411 2 411 3 5 9 QE


Dy.CEE/D&D
+24V

B B B B A 2
411.JA
10
411.OD
3
411.JD
3
411.OD
11
411.JD
11
411.OD
4
411.JD
4
411.OD

B B B B B B B B
STB1 HBB1 STB1 HBB1 FLG1
AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- STB1 HBB1 STB1 HBB1 STB1 HBB1 STB1 HBB1
I

AMSB_0101- AMSB_0101- AMSB_0103- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101-


LTrvDirFor LTrvDirFor LTrvDirRev LTrvDirRev XAngTrans LTEDemand LTEDemand LBEDemand LBEDemand LT/BDem>1/3 LT/BDem>1/3 LT/BDem>2/3 LT/BDem>2/3
J

CHITTARANJAN LOCOMOTIVE WORKS


Chittaranjan
CENTRE FOR DESIGN AND DEVELPOMENT
K

08C
SSE/D&D. AEE/D&D
08D
Angle
Reverser Trasmitter Throttle Auxiliary Contacts Position Function Description Pin layout

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 140 Switch Travel Direction(Reverser)


150 Throttle Tractive Effort/Regenerative Brake
A

04C 09
150.1 Angle Transmitter Drive Controller
2111B 150.A/2 150.A Connertor
1 150.B Connector
412 Central Electronics 2(CEL-2)
412.EA Connector 28A
412.OD Connector 28A
B

412.JD Connector 28A


412.JA Connector 28A

TEMax TEMax TEMax TEMax


C

2/3TE 2/3TE 2/3TE 2/3TE

F 1 F 3 F 5 F 7 140/1 1/3TE 1 1/3TE 3 1/3TE 5 1/3TE 150/1


7

0 0 0 0 0 0 0 0
D

R 2 R 4 R 6 R 8 1/3BE 2 1/3BE 4 1/3BE 6 1/3BE 8


2+ 4+ -1
2/3BE 2/3BE 2/3BE 2/3BE

BEMax BEMax BEMax BEMax


E

3 5 9 QE
2 3 4 5 6 7 8 9
150.A/1
F

2520B

2521B

2522B

2523B
2524B

2525B

2526B

2527B

CAB REDUNDANCY
FOR
G

WAG-9/ WAP-7/ WAP-5

2521B

2521B

2523B

2523B
2520B

2520B

2522B

2522B
412.JD 412.OD 412.JD 412.QD 412.EA
H

9 412 9 412 2 412 2 412 3 5 9 QE


+24V

B B B B A 412.JA 412.OD 412.JA 412.OD 412.JD 412.OD 412.JD 412.OD


1 10 2 3 10 11 4 4 Dy.CEE/D&D
B B B B B B B B
STB2 HBB2 STB2 HBB2 FLG2
AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- STB2 HBB2 STB2 HBB2 STB2 HBB2 STB2 HBB2
I

AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0103- AMSB_0101-


LTrvDirFor LTrvDirFor LTrvDirRev LTrvDirRev XAngTrans LTEDemand LTEDemand LBEDemand LBEDemand LT/BDem>1/3 LT/BDem>1/3 LT/BDem>2/3 LT/BDem>2/3
J

CHITTARANJAN LOCOMOTIVE WORKS


Chittaranjan
CENTRE FOR DESIGN AND DEVELPOMENT
K

08D
SSE/D&D. AEE/D&D
17A
Driver's Cab 1 Fault Status Driver's Cab 2 Fault Status Faliure Mode Operation Simulation Position Function Description Pin layout
Fault Acknowledge Fault Acknowledge

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
04C 06 04C 09 04E 01 152 Rotary Switch Failure Mode Operation
A

163 Fault Status Lamp "LSFI"


163.1 Illum. Push Button Fault Ack. "BPFA"
179 Key Switch Simulation

2111A

2111B
411 Central Electronics 1 (CEL 1)
411.LA Connector 28B

4201

4201
411.LD Connector 28B
411.OD Connector 28B
B

13 163.1/1 13 163.1/2 I 1 152


I 1 179
411.OG Connector 28B
0 SIM 412 Central Electronics 1 (CEL 1)
412.OD Connector 28E
14 14 2 2
412.OG Connector 28E
C

5671A

5671A

5671B

5671B

5676
5675

5675
411.OD 411.LA 412.OD 411.OA 411.QD 411.LA 411.LD
12 411 4 411 12 412 1 411 12 411 3 411 2 411

B B B B B B B
D

HBB1 STB1 HBB2 HBB1 HBB1 STB1 STB1


AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0101- AMSB_0102- AMSB_0102- AMSB_0102-
LPBFaultAck LPBFaultAck LPBFaultAck LPBFaultAckt LSwFailMode LSwFailMode LSwKSim
E

04F 06 04F 14
F

2099A

2099A

2099A

2099A

2099B

2099B

2099B

2099B
CAB REDUNDANCY
G

411.OG 411.JG 411.JJ 412.OG 412.JG 412.JG


7 411 4 411 INT 411 6 411 7 412 4 412 INT 412 3 412 FOR
HBB1 STB1 HBB1 STB1 HBB2 STB2 HBB2 STB2 WAG-9/ WAP-7/ WAP-5
AMSB_0201- AMSB_0201- AMSB_0201- AMSB_0201- AMSB_0201- AMSB_0201- AMSB_0201- AMSB_0201-
MLampFInd MLampFInd MLampFault MLampFault MLampFInd MLampFInd MLampFault MLampFault
H

19 411.OG 17 411.JG 20 411.OG 13 411.JJ 19 412.OG 17 412.JG 20 412.OG 15 412.JG Dy.CEE/D&D


5672A

5672A

5673A

5673A

5672B

5672B

5673B

5673B
I

X1+ X1+ X1+ X1+

163.1/1 163/1 163.1/2 163/2


J

X2- X2- X2- X2-


2050
2050
2050

2050

CHITTARANJAN LOCOMOTIVE WORKS


Chittaranjan
CENTRE FOR DESIGN AND DEVELPOMENT
K

04B 01 SSE/D&D AEE/D&D 17A


EMERGENCY
COMPRESSOR
SWITCH
Contactor Aux. Compressor Low Contactor Brake Contactor
06E
Switch
Main Compressor Main Compressor 1 Main Reservoir Main Compressor 2 Feed Pipe Aux. Compressor Position Function Description Pin layout

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15
47.2 Contactor Main Compressor 25B
47.2A Snubber ckt. to item no. 47.2
A

04C 06 04C 10 04E 07 04E 05 06A 09 04C 11 48 Aux. Compressor Unit (17)
48.2 Contactor Aux. Compressor
123 Blocking Diodes 26C
172 Spring loaded switch Compressor "BLCP"

2069
3090
172.2 Pressure switch Main compressor (35)
2111A

2111A
172.3 Pressure switch Main compressor (36)
172.4 Pressure switch Aux. compressor (26)
B

3101

3101
3101

3101

3101
260 Control Electr Pneu. Equipment (45)
OFF A1 OFF B1 260.B 260.B Connector Ctrl Electr Pneu. Equ. (172) 27A
AUTO AUTO 172/1 SJ 260 260.D Connector Ctrl Electr Pneu. Equ. (172) 27A
Q3 172.2 Q1 172.2 Q3 172.3 Q1 172.3 Q1 269.4 Pressure switch Low Main resorvoir(37)
MAN MAN 269.4
A2 B2 P10 269.42Pressure switch Brake feed pipe (34)
P10 P10 P6.4
P10 411 Ctnral Electronics 1 (CEL 1)
C

Q4 < 8.0 Q2 < 8.0 Q4 < 7.5 Q2 < 7.5 Q2 < 5.6 411.LJ Connector 28B

3035

3035
3035AA

4204

4203
3034A

411.OA Connector 28B


411.OJ Connector 28B
1 411.LA Connector 28B
I ECPSW SJ 411.LD Connector 28B
0 260.D
412 Ctnral Electronics 2 (CEL 2)

3090

3025
2
D

3036
412.JJ Connector 28E

3038

3044
412.QD 412.QD 412.QD
4 412 2 412 11 412 412.OA Connector 28E
3035A

Q1 Q1 412.QD Connector 28E


411.OA 411.OA 412.QJ 412.JJ 269.42 172.4
4 411 12 411 3 412 4 412 412.QJ Connector 28E
B B B P5.6 P6.0
HBB2 STB2
AMSB_0202- Q2 < 5.0 Q2 < 5.2
AMSB_0201- Material Added
B B BContCompr2
E

BContCompr2

3045
HBB2

3018
HBB2 HBB2 1) ECPSW- Emergency Compressor switch, Type- F/SU/9/
AMSB_0102- AMSB_0102- AMSB_0102-
MPrSw8bar MPrSw7.5bar MPrSwLowMR
Z SK R20 S84, 2 Position, 6A-250V (Marker Light sw) or
HBB1 HBB1
AMSB_0101- AMSB_0101- Rotary switch similar to HQOA/HCPA used in
LSwComprOff LSwComprDir convetional locos. Location-SB1 Panel, Qty:1 No.
04E 01 04E 03
10 412.QJ 12 412.JJ 2) D1- Diode, DIBLO-5/ HR20 (HIRECT MAKE).
SK 260.B
4202
4201
F

3116

3118
Location- CAB1, F-Panel, Qty: 1 No.
04C 09 411.LJ 411.OJ 1 3
9 411 2 411
04C 02 123/8 123/8
2111B

STB1 HBB1
2 4
AMSB_0202- AMSB_0201-

2068
BContCompr1 BContCompr1

3037B
CAB REDUNDANCY

3037B
G

OFF A1 OFF B1 +1 FOR


AUTO AUTO 172/2 48.2
WAG-9/ WAP-7/ WAP-5
MAN MAN 2 411.LJ 9 411.OJ -2
3115
3114

A2 B2
7 9
H

3027

123/5 123/5

3043

3026
8 10
3037A

3037A

Dy.CEE/D&D
Z 48
3035B

3035B
3034B

412.QD
47.2A/2 12 412
I

1+ 2+ 47.2A/1 1+ 2+
M

3037B
411.LA 412.OA 412.OA 411.LD
3037A

12 411 4 412 12 412 12 411


A1 B A1 48.2
A1
47.2/2 DT
47.2/1
B B B B A2 A2 HBB2 A2
ZZ
AMSB_0102-
J

2050

2050
2050

STB1 HBB2 HBB2 STB1 MprSwBkFP


4- 3- 4- 3-
AMSB_0102- AMSB_0101- AMSB_0101- AMSB_0102-
LSwComprOff LSwComprOff LSwComprDir LSwComprDir
CHITTARANJAN LOCOMOTIVE WORKS
Chittaranjan
04B 01 CENTRE FOR DESIGN AND DEVELPOMENT
K

SSE/D&D 06E
AEE/D&D
CABLE INDEX FOR CAB REDUNDANCY ANNEXURE-I & II
INPUT REDUNDANCY

Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

1 AMSB_0101-LBEDemand HBB-1 STB-1 08C 2521A 0.5 mm SB-1 XF22S:02 23 411 JD:03
2 AMSB_0101-LTEDemand HBB-1 STB-1 08C 2520A 0.5 mm SB-1 XF22S:02 22 411 JA:02
3 AMSB_0101-LT/BDem>1/3 HBB-1 STB-1 08C 2522A 0.5 mm SB-1 XF22S:02 24 411 JD:11
4 AMSB_0101-LT/BDem>2/3 HBB-1 STB-1 08C 2523A 0.5 mm SB-1 XF22S:02 25 411 JD:04
5 AMSB_0101-LPBFaultAck HBB-1 STB-1 17A 5671A 0.5 mm SB-1 XF22S:03 4 411 LA:04
6 AMSB_0101-LBEDemand HBB-2 STB-2 08D 2521B 0.5 mm SB-2 XF77S:02 2 412 JA:02
7 AMSB_0101-LTEDemand HBB-2 STB-2 08D 2520B 0.5 mm SB-2 XF77S:01 1 412 JA:01
8 AMSB_0101-LT/BDem>1/3 HBB-2 STB-2 08D 2522B 0.5 mm SB-2 XF77S:02 3 412 JD:10
9 AMSB_0101-LT/BDem>2/3 HBB-2 STB-2 08D 2523B 0.5 mm SB-2 XF77S:02 4 412 JD:04
10 AMSB_0101-LPBFAulAckt HBB-2 HBB-1 17A 5671B 1.5 mm SB-2 XF77S:03 4 SB-2 XK77V:03-21
1.5 mm SB-2 XK77V:03 21 SB-1 XK22V:03-21
1.5 mm SB-1 XK22V:03 21 SB-1 XF22S:02-51
0.5 mm SB-1 XF22S:02 51 411 OA:01
11 AMSB_0101-LActKD STB-1 HBB-1 08A 2500A 0.5 mm SB-1 XF22S:02 17 411 OA:09
12 AMSB_0101-LActKD STB-2 HBB-2 08A 2500B 0.5 mm SB-2 XF77S:03 20 412 OA:09
13 AMSB_0101-LSwComprDir HBB-1 ***** 06E 3035 1.5 mm **** 172.2 Q4 SB-2 XK77D-14
1.5 mm SB-2 XK77D 14 SB-2 XF77S:01-49
1.5 mm SB-2 XF77S:01 49 SB-2 XK77V:03-22
1.5 mm SB-2 XK77V:03 22 SB-1 XK22V:03-22
1.5 mm SB-1 XK22V:03 22 SB-1 XF22S:03-32
1.5 mm SB-1 XF22S:03 32 SB-1 ECPSW -1
3035A 1.5 mm SB-1 ECPSW 2 SB-1 XF22S:03-28
14 AMSB_0102-LSwComprOff HBB-2 STB-1 06E 3034B 1.5 mm SB-2 XF77S:03 27 SB-2 XK77V:03-18
1.5 mm SB-2 XK77V:03 18 SB-1 XK22V:03-18
1.5 mm SB-1 XK22V:03 18 SB-1 XF22S:02-48
0.5 mm SB-1 XF22S:02 48 411 LA:12
Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

15 AMSB_0102-LSwComprDir HBB-2 STB-1 06E 3035B 1.5 mm SB-2 XF77S:03 26 SB-2 XK77V:03-19
1.5 mm SB-2 XK77V:03 19 SB-1 XK22V:03-19
1.5 mm SB-1 XK22V:03 19 SB-1 XF22S:02-49
0.5 mm SB-1 XF22S:02 49 411 LD:12
16 AMSB_0102-MBrakElecOk HBB-2 STB-1 06H 3008 1.5 mm SB-2 XF77S:01 17 SB-2 XK77V:03-20
1.5 mm SB-2 XK77V:03 20 SB-1 XK22V:03-20
1.5 mm SB-1 XK22V:03 20 SB-1 XF22S:02-50
0.5 mm SB-1 XF22S:02 50 411 JD:12
17 AMSB_0102-LSwFailMode STB1 HBB1 17A 5675 1.5 mm SB-1 152 2 411 QD:12
18 AMSB_0102-MEFRHotel HBB1 **** 05D 2860 0.5 mm SB-1 XF22S:03 56 SB-1 411.QD 9
19 AMSB_0102-MContHotel STB1 **** 05D 2806 0.5 mm SB-1 XF22S:03 55 SB-1 411.LD 10
20 05D UH10 0.5 mm SB-1 XF22S:01 1 SB-1 XF22S:02/56

OUTPUT REDUNDANCY

Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

1 AMSB_0201-MLampFault HBB-1 STB-1 17A 2099A 0.5 mm SB-1 XF22S:02 3 411 JJ:06
2 AMSB_0201-MLampFault HBB-1 STB-1 17A 5673A 0.5 mm SB-1 XF22S:03 6 411 JJ:13
3 AMSB_0201-MLampFind HBB-1 STB-1 17A 5672A 0.5 mm SB-1 XF22S:03 5 411 JG:17
4 AMSB_0201-MLampFind HBB-1 STB-1 17A 2099A 0.5 mm SB-1 XF22S:02 5 411 JG:04
5 AMSB_0201-MLampFault HBB-2 STB-2 17A 2099B 0.5 mm SB-2 XF77S:03 7 412 JG:03
6 AMSB_0201-MLampFault HBB-2 STB-2 17A 5673B 0.5 mm SB-2 XF77S:02 12 412 JG:15
7 AMSB_0201-MLampFind HBB-2 STB-2 17A 2099B 0.5 mm SB-2 XF77S:03 8 412 JG:04
8 AMSB_0201-MLampFind HBB-2 STB-2 17A 5672B 0.5 mm SB-2 XF77S:03 11 412 JG:17
9 AMSB_0202-BHLC1ON STB1 **** 05D HL01 0.5 mm SB-1 XF22S:01 53 SB-1 411.LJ 6
10 AMSB_0202-BHLC1ON STB1 **** 05D HL11 0.5 mm SB-1 XF22S:03 57 SB-1 411.LJ 13
11 AMSB_0202-BHLC2ON STB2 **** 05D HL02 0.5 mm SB-2 XF77S:01 54 SB-2 412.LJ 6
Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

12 AMSB_0202-BHLC2ON STB2 **** 05D HL12 0.5 mm SB-2 XF77S:03 55 SB-2 412.LJ 13
13 AMSB_0201-BContHotel STB1 **** 05D UH05 0.5 mm SB-1 XF22S:01 52 SB-1 411.JJ 2
14 AMSB_0201-BContHotel STB1 **** 05D 2805 0.5 mm SB-1 XF22S:01 1 SB-1 411.JJ 9

Additional Cable to be done for Paralleling SB1 and SB2


Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

1 13B UH01 2.5 mm SB-1 XK22V:03 1 SB-2 XK77V:03/1


2 13B UH02 2.5 mm SB-1 XK22V:03 2 SB-2 XK77V:03/2
3 13B UH03 2.5 mm SB-1 XK22V:03 3 SB-2 XK77V:03/3
4 13B UH04 2.5 mm SB-1 XK22V:03 4 SB-2 XK77V:03/4
5 13B UH05 2.5 mm SB-1 XK22V:03 5 SB-2 XK77V:03/5
6 13B UH06 2.5 mm SB-1 XK22V:02 48 SB-2 XK77V:02/48
7 13B UH07 2.5 mm SB-1 XK22V:02 49 SB-2 XK77V:02/49
8 13B UH08 2.5 mm SB-1 XK22V:02 50 SB-2 XK77V:02/50
9 13B UH09 2.5 mm SB-1 XK22V:02 51 SB-2 XK77V:02/51
10 13B UH10 2.5 mm SB-1 XK22V:02 52 SB-2 XK77V:02/52
11 13B UH11 2.5 mm SB-1 XK22V:02 53 SB-2 XK77V:02/53
12 13B UH12 2.5 mm SB-1 XK22V:02 54 SB-2 XK77V:02/54
13 13B 2806 2.5 mm SB-1 XK22V:02 55 SB-2 XK77V:02/55
14 13B 2860 2.5 mm SB-1 XK22V:02 56 SB-2 XK77V:02/56
15 13B HL01 2.5 mm SB-1 XK22V:02 57 SB-2 XK77V:02/57
16 13B HL02 2.5 mm SB-1 XK22V:02 58 SB-2 XK77V:02/58

This Wiring to be done only if Hotel load is installed with common Filter Cubicle of WAG9 (removal of 32 and 33)
Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

1 HLC1 O/P Available Indication 13B UH01 1.5mm SB-1 XF22S:01 48 HLC1 1
2 HLC1 Fault Indication 13B UH02 1.5mm SB-1 XF22S:01 49 HLC1 2
3 HLC1 RESET 13B UH03 1.5mm SB-1 XF22S:01 50 HLC1 3
Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

4 HLC1 RESET Feedback 13B UH04 1.5mm SB-1 XF22S:01 51 HLC1 4


5 24V supply from Power Car 13B UH05 1.5mm SB-1 XF22S:01 52 HLC1 5
6 +110V DC from Loco Battery 13B UH11 1.5mm SB-1 XF22S:03 53 HLC1 11
7 -110V DC from Loco Battery 13B UH12 1.5mm SB-1 XF22S:03 54 HLC1 12
8 Message Contactor status HLC1 13B 2806 1.5mm SB-1 XF22S:03 55 HLC1 13
9 EarthFault Signal HLC1 13B 2860 1.5mm SB-1 XF22S:03 56 HLC1 14
10 HLC1 ON Command 13B HL11 1.5mm SB-1 XF22S:03 57 HLC1 15
11 24V supply from Power Car 13B UH05 1.5mm SB-2 XF77S:01 52 HLC2 5
12 HLC2 O/P Available Indication 13B UH06 1.5mm SB-2 XF77S:02 52 HLC2 1
13 HLC2 Fault Indication 13B UH07 1.5mm SB-2 XF77S:02 53 HLC2 2
14 HLC2 RESET 13B UH08 1.5mm SB-2 XF77S:02 54 HLC2 3
15 HLC2 RESET Feedback 13B UH09 1.5mm SB-2 XF77S:02 55 HLC2 4
16 +110V DC from Loco Battery 13B UH11 1.5mm SB-2 XF77S:03 51 HLC2 11
17 -110V DC from Loco Battery 13B UH12 1.5mm SB-2 XF77S:03 52 HLC2 12
18 Message Contactor status HLC2 13B 2806 1.5mm SB-2 XF77S:03 53 HLC2 13
19 EarthFault Signal HLC2 13B 2860 1.5mm SB-2 XF77S:03 54 HLC2 14
20 HLC2 ON Command 13B HL12 1.5mm SB-2 XF77S:03 55 HLC2 15
21 CAB1 UIC SOCKET TO SB1 (FOR HOTEL 13B UH01 1.5mm HLC1 353.3/3 1 SB-1 XK22HL:01/1
22 LOAD) 13B UH02 1.5mm HLC1 353.3/3 2 SB-1 XK22HL:01/2
23 13B UH03 1.5mm HLC1 353.3/3 3 SB-1 XK22HL:01/3
24 13B UH04 1.5mm HLC1 353.3/3 4 SB-1 XK22HL:01/4
25 13B UH05 1.5mm HLC1 353.3/3 5 SB-1 XK22HL:01/5
26 13B UH06 1.5mm HLC1 353.3/3 6 SB-1 XK22HL:01/6
27 13B UH07 1.5mm HLC1 353.3/3 7 SB-1 XK22HL:01/7
28 13B UH08 1.5mm HLC1 353.3/3 8 SB-1 XK22HL:01/8
29 13B UH09 1.5mm HLC1 353.3/3 9 SB-1 XK22HL:01/9
30 13B UH10 1.5mm HLC1 353.3/3 10 SB-1 XK22HL:01/10
31 13B UH11 1.5mm HLC1 353.3/3 11 SB-1 XK22HL:01/11
32 13B UH12 1.5mm HLC1 353.3/3 12 SB-1 XK22HL:01/12
33 13B UH13 1.5mm HLC1 353.3/3 13 SB-1 XK22HL:01/13
Sl. No. Signal Name Existing Redundant Scheme No Cable Size of FROM TO
processor processor No cable Panel Location Wago To SUB-D
No /Connector PIN

34 CAB2 UIC SOCKET TO SB2 (FOR HOTEL 13B UH01 1.5mm HLC2 353.3/2 1 SB-2 XK77HL:02/1
35 LOAD) 13B UH02 1.5mm HLC2 353.3/2 2 SB-2 XK77HL:02/2
36 13B UH03 1.5mm HLC2 353.3/2 3 SB-2 XK77HL:02/3
37 13B UH04 1.5mm HLC2 353.3/2 4 SB-2 XK77HL:02/4
38 13B UH05 1.5mm HLC2 353.3/2 5 SB-2 XK77HL:02/5
39 13B UH06 1.5mm HLC2 353.3/2 6 SB-2 XK77HL:02/6
40 13B UH07 1.5mm HLC2 353.3/2 7 SB-2 XK77HL:02/7
41 13B UH08 1.5mm HLC2 353.3/2 8 SB-2 XK77HL:02/8
42 13B UH09 1.5mm HLC2 353.3/2 9 SB-2 XK77HL:02/9
43 13B UH10 1.5mm HLC2 353.3/2 10 SB-2 XK77HL:02/10
44 13B UH11 1.5mm HLC2 353.3/2 11 SB-2 XK77HL:02/11
45 13B UH12 1.5mm HLC2 353.3/2 12 SB-2 XK77HL:02/12
46 13B UH13 1.5mm HLC2 353.3/2 13 SB-2 XK77HL:02/13
47 HLC1 LEM SENSOR TO SR-1 05D 1548A 0.5mm 33.A/1 8 SR-1 415.AG/1 (7)
48 05D 1549A 0.5mm 33.A/1 9 SR-1 415.AG/1 (8)
49 05D 1541A 0.5mm HLC1 LEM 33.A/1 1 SR-1 415.AG/1 (3)
50 05D 1542A 0.5mm SENSOR 33.A/1 2 SR-1 415.AG/1 (6)
51 05D 1543A 0.5mm 33.A/1 3 SR-1 415.AG/1 (2)
52 05D 1544A EARTHING 33.A/1 4 SR-1 415.AG/1 (QE)
53 HLC2 LEM SENSOR TO SR-2 05D 1548B 0.5mm 33.A/2 8 SR-2 415.AG/2 (7)
54 05D 1549B 0.5mm 33.A/2 9 SR-2 415.AG/2 (8)
55 05D 1541B 0.5mm HLC2 LEM 33.A/2 1 SR-2 415.AG/2 (3)
56 05D 1542B 0.5mm SENSOR 33.A/2 2 SR-2 415.AG/2 (6)
57 05D 1543B 0.5mm 33.A/2 3 SR-2 415.AG/2 (2)
58 05D 1544B EARTHING 33.A/2 4 SR-2 415.AG/2 (QE)
59 IVC TO SB1 05D HL01 2.5mm CAB1 IVC ALP 7,10 SB-1 XF22S:01/53
60 05D HL02 2.5mm CAB1 IVC LP 7,10 SB-1 XF22S:01/54
61 IVC TO SB2 05D HL01 2.5mm CAB2 IVC ALP 7,10 SB-2 XF77S:01/53
62 05D HL02 2.5mm CAB2 7,10 LP 7,10 SB-2 XF77S:01/54
VCU RESET
Temperature Indication BP Droping
08B
Contactor
Control Control electronics Temperature of Control Electronics Position Function Description Pin layout

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 86 Minimum Voltage Relay 26A


123 Blocking Diodes 26C
A

04C 11 04E 01 04E 03 04F 06 07E 13 04F 14 07E 15 04C 11


123.1 Blocking Diodes Illum. Test 26C
126.6 Safety relay cntrl.Electronics ON 25C
161A Illuminated Push Button RESET
166 Indication Lamp temp. Electronics ON 'LSCE"
211 Relay Temp. Control Electronics 25C
211.1 Thermostat Control Electronics
2069

2069

2069

2069

2099B
3503A

3503B
2099A

2069
211.A Snubber Circuit To Item No. 211
B

4201

4202
19 218 Contactor Control Electronics 25C
Q1 Q1 411 Central Electronics 1 (CEL 1)
211.1/1 211.1/1
86 13 411.LA Connector 28B
21 31 RESET 411.LG Connector 28B
70 C 70 C SWITCH 411.OJ Connector 28B
Q2 Q2 211 211 14
C

18
2511
22 32
2510
2510

2069A
43 43
14 14 Material Added
126.6 211 123.1/2 1) RESET Switch- Illumination Push Button similar
123.1/1 21
D

to switch 151.4, Location- SB1, next to Simulation Key


44 44 2 2 130.1 and 161 config switch, Qty: 1 No.

22 2) RESET Relay- Aux. Contactor, Type-CA3-DN22FW,


similar to relay 126.5, Location-SB1, Qty: 1 No.
13 411.LA 411.LG 411.OJ
1 6 10 411 3) 1 NC Aux. Contact- For Relay no.130.1 and 136.4

2514B
411 411

2514A

2514A

2514B

2069B
E

211
14 STB1 HBB1
AMSB_0202- AMSB_0201-
2515

B
BSelfMEC BSelfMEC
1
123/7 STB1
F

AMSB_0102- 21
2
MReTempCEL 136.4
18 3 22
411.LG 411.OJ

2519
2518

CAB REDUNDANCY
2513
2510

3 5

2069C
G

123/7 123/7 FOR


21
4 6 WAG-9/ WAP-7/ WAP-5
RESET
211.A 22 2513
1+ 2+ 1+ 2+
2513A
H

2069C
2510

2514B
2514A
A1 A1 A1 Dy.CEE/D&D
211 DT 218 X1+ X1+
RESET
A2 A2 166/1 166/2 A2
I

2050

2050
X2- X2-
4- 3-
2050

2050

2050
4- 3-
J

2050

CHITTARANJAN LOCOMOTIVE WORKS


Chittaranjan
04B 01
CENTRE FOR DESIGN AND DEVELPOMENT
K

SSE/D&D AEE/D&D 08B


ADDITIONAL WIRING FOR CAB REDUNDANCY ANNEXURE-3

Sl. No. Drg. No. Cable No. Cable Size FROM TO


Panel Location Wago No To SUB-D
/Connector
PIN
1 08B 2069 1.5 mm SB-1 XF22S:01 1 SB-1 RESET-13
2 08B 2069A 1.5 mm SB-1 RESET 14 SB-1 XK22V:02-49
1.5 mm SB-1 XK22V:02 59 SB-2 XK77V:02-59
1.5 mm SB-2 XK77V:02 59 SB-2 XF77S:01-53
1.5 mm SB-2 XF77S:01 49 SB-2 130.1-21
3 08B 2069B 1.5 mm SB-2 130.1 22 SB-2 XF77S:01-53
1.5 mm SB-2 XF77S:01 53 SB-2 XK77V:02-60
1.5 mm SB-2 XK77V:02 60 SB-1 XK22V:02-60
1.5 mm SB-1 XK22V:02 60 SB-1 XF22S:01-53
1.5 mm SB-1 XF22S:01 53 SB-1 136.4-21
4 08B 2069C 1.5 mm SB-1 136.4 22 SB-1 RESET-A1
5 08B 2050 1.5 mm SB-1 RESET A2 SB-1 XF22S:
6 08B 2513 1.5 mm SB-1 XF22S.01 14 SB-1 RESET-21
7 08B 2513A 1.5 mm SB-1 RESET 22 SB-1 218-A1
PARALLELING OF
DIODE FOR
RELIABILITY
IMPROVEMENT
Paralleling of Diodes for realibility improvement of WAG9/WAP7 ANNEXURE-4
The following diode terminal shall be shorted at Incoming side
Sl. No. Circuit Drg. Diode Terminal Cable WAGO No. To be shorted Terminal Cable WAGO No.
No. no. No. with Diode no. for No.
Paralleling
1 Main Compressor-1 06C 123/5 7 3114 XF22S:01/21 123/5 9 3115 XF22S:01/23
2 Main Compressor-2 06C 123/8 1 3116 XF77S:02/05 123/8 3 3118 XF77S:02/06
3 Cut out of Loco Brake 06D 123/6 1 3110 XF77S:02/01 123/6 3 3111 XF77S:02/02
4 Unloader 06D 123/6 5 3112 XF77S:02/03 123/6 7 3113 XF77S:02/04
5 Self hold for 126 8A 123/5 5 2509 # 123/1 9 2506 #
6 Self hold for 218 8B 123/7 3 2518 XF22S:01/15 123/7 5 2519 XF22S:01/23

NOTE
# Existing pin in diode box to be removed and new pin is to be provided with looping both the pins at diode base.
Paralleling of Diodes for realibility improvement of WAG9/WAP7 ANNEXURE-5
The Following diodes shall be connected with parallel with the spare diode terminals
Sl. Circuit Drg. No. Diode No. Terminal Location Cable No. Wago No. Spare Terminal Location/Wago No. Remarks
No. Diode no. to be shorted

1 Cab1 Panto Switch 5A 123/3 7 SB-1 2333A XF22S:02/15 123/8 1


8 2319 XF22S:01/6 2
2 Cab2 Panto Switch 5A 123/4 3 SB-2 2333B XF77S:01/45 123/8 7 XK77A:01/23 shall be connected to
4 2319 XF77S:01/12 8 WAGO XF77S:01/45
3 130.1 Self interlock 5A 123/8 5 SB-2 2302 XF77S:01/6 123/9 5
6 2319 XF77S:01/12 6
4 Cab1 VCB Switch 5B 123/3 9 SB-1 2334A XF22S:02/16 123/8 3
10 2327 XF22S:01/10 4
5 Cab2 VCB Switch 5B 123/4 5 SB-2 2334B XF77S:01/46 123/9 7 XK77A:01/24 shall be connected to
6 2327 XF77S:01/13 8 WAGO XF77S:01/46
6 136.4 Self Interlock 5B 123/7 7 SB-1 2312 XF22S:01/2 123/8 5
8 2327 XF22S:01/10 6
7 Contactor 218 8B 123/7 1 SB-1 2515 XF22S:01/45 123/3 5 XK22V:01/29 shall be connected to
2 2513 XF22S:01/14 6 WAGO XF22S:01/46
8 Cab1 'D' mode 126.6 8A 123/1 1 SB-1 2500A XF22S:02/17 123/3 3
2 2501 XF22S:01/11 4
9 Cab2 'D' mode 126.6 8A 123/1 3 SB-1 2500B XF22S:02/18 123/9 9 SB-2, XF77S:03/20 Cable no. 2500B available in SB2
4 2501 XF22S:01/11 10 SB-2, XF77S:01/14 Cable no. 2505 available in SB2
10 Cab1 'C/D' mode 126 8A 123/1 5 SB-1 2503A XF22S:02/19 123/2 7 SB-2, XF77S:03/21 Cable no. 2503A available in SB2
6 2505 XF22S:01/12 8 SB-2, XF77S:02/45 Ref Note-1
11 Cab2 'C/D' mode 126 8A 123/1 7 SB-1 2503B XF22S:02/20 123/2 9 SB-2, XF77S:02/46 Ref Note-2
8 2505 XF22S:01/12 10 SB-2, XF77S:01/45 Ref Note-1
12 Cab1 Front HL 7C 123/9 1 SB-1 3542A XF22S:03/40 123/6 9 SB2, XF77S:03/45 Ref Note-3
2 3542C XF22S:03/41 10 SB2, XF77S:03/41 Cable no. 3542C available in SB2
13 Cab2 'C/D' mode 126 7C 123/8 7 SB-2 3542B XF77S:03/40 123/8 9 SB2, XF77S:03/40 Cable no. 3542B available in SB2
8 3542D XF77S:03/41 10 SB2, XF77S:03/42 Cable no. 3542D available in SB2

NOTE
1 2505 cable is not available in SB2. Hence spare cable in coupler XK22V:01/2 is used from SB1 to SB2.
Cable from Wago XF22S:01/12 is to be connected to XK22V:01/2 and at SB2 the cable is to be run to spare
wago XF77S:02/45 through XK22V:01/2
2 2503B cable is not available in SB2. Hence spare cable in coupler XK22V:01/3 is used from SB1 to SB2.
Cable from Wago XF22S:02/20 is to be connected to XK22V:01/3 and at SB2 the cable is to be run to spare
wago XF77S:02/46 through XK22V:01/3
3 3542A cable is not available in SB2. Hence spare cable in coupler XK22V:01/4 is used from SB1 to SB2.
Cable from Wago XF22S:03/40 is to be connected to XK22V:01/4 and at SB2 the cable is to be run to spare
wago XF77S:03/45 through XK22V:01/4