Model Site - Good Example - of Installation For Indoor

This document provides examples of indoor model mobile network installations. It shows diagrams and descriptions of indoor cabinet installations with double and single tiers. The examples demonstrate best practices for cable organization, labeling, grounding, power connections, bending radii and cable separation. Maintaining tidy, clearly labeled and properly grounded installations is emphasized.

Uploaded by

Arsyad Mhd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
68 views7 pages

Model Site - Good Example - of Installation For Indoor

This document provides examples of indoor model mobile network installations. It shows diagrams and descriptions of indoor cabinet installations with double and single tiers. The examples demonstrate best practices for cable organization, labeling, grounding, power connections, bending radii and cable separation. Maintaining tidy, clearly labeled and properly grounded installations is emphasized.

Uploaded by

Arsyad Mhd
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 7

Confidentiality level:

Telkomsel Project:Model Site/Good Example (indoor) For internal use only

Model Site/Good Example of Installation (indoor-BTS3900).


Part A: Double Tiers

-Overview of outside the cabinet -Overview of inside the cabinet

-Color ring of the feeder cable -Color ring of the feeder cable
(front view) (side view)

Huawei Confidential. No disclosure without permission. Page 1 of 7


Confidentiality level:
Telkomsel Project:Model Site/Good Example (indoor) For internal use only

-Labeling at same direction and tidy -Labeling at same direction and tidy
(top tier) (lower tier)
-CPRI cable(optical) installed smoothly -CPRI cable(optical) installed smoothly

-feeder cable at lower tier and - Grounding between DCDU and


Its color ring cabinet
-BBU on the top of DCDU

Huawei Confidential. No disclosure without permission. Page 2 of 7


Confidentiality level:
Telkomsel Project:Model Site/Good Example (indoor) For internal use only

-Grounding between cabinet and door -Grounding btw BBU and cabinet

-Grounding at the cabinet to -Grounding at the grounding bar.


grounding bar(with PGND label). (with PGND label)

Huawei Confidential. No disclosure without permission. Page 3 of 7


Confidentiality level:
Telkomsel Project:Model Site/Good Example (indoor) For internal use only

Grounding between 2 tiers

-Power cable and grounding -Power cable connection at


(straight and smooth) upper tier.(with -48V label)
-Power cable size:≥16mm ²

Huawei Confidential. No disclosure without permission. Page 4 of 7


Confidentiality level:
Telkomsel Project:Model Site/Good Example (indoor) For internal use only

-Power cable connection at top tier -Power cable connection at rectifier


(with -48V label) (with -48V label)

-Redundancy of E1 cable (tidy) -Connection at DDF

Huawei Confidential. No disclosure without permission. Page 5 of 7


Confidentiality level:
Telkomsel Project:Model Site/Good Example (indoor) For internal use only

Part B: Single Tier

-Feeder cable connection -Connection and labeling inside the


cabinet

-Feeder cable connection -Feeder cable connection


(bending radius:20x its diameter)

Huawei Confidential. No disclosure without permission. Page 6 of 7


Confidentiality level:
Telkomsel Project:Model Site/Good Example (indoor) For internal use only

Power/Ground cable must be separated minimum 3cm from signal cable

Prepared by Foo Siang Hooi

Huawei Confidential. No disclosure without permission. Page 7 of 7