error Е396
error Е396
The Electronic Control Module (ECM) detects excessive fuel rail pressure. The ECM detects the following faults:
PPI
The ECM detects fuel rail pressure that is more than the pressure that is required for the operating conditions.
- 0
Diagnostic code 0262-03 5 Volt Sensor DC Power Supply voltage above normal is not active.
202 006
Diagnostic code 0262-04 5 Volt Sensor DC Power Supply voltage below normal is not active.
1
11: /05/2 C98 E
Diagnostic code 1797-03 Fuel Rail Pressure Sensor voltage above normal is not active.
Diagnostic code 1797-04 Fuel Rail Pressure Sensor voltage below normal is not active.
1
SEN :37+1
No diagnostic codes are active for the fuel rail pump.
E396-1
Cat 1 C2
e r
Con pilla terpia
The engine will be derated until the keyswitch is turned to OFF.
Test Step 1.
fide r: llar
The event code does not indicate a fault with the electronic system. This event indicates high fuel pressure. Refer to Systems Operation, Testing
Inc
and Adjusting, "Fuel System - Inspect".
ntia .
A failed relief valve, the fuel pump or an electronic unit injector may cause an event code to be logged.
Results:
lG
OK - STOP
ree
PPI-0006EC98
2021/05/28
n
11:11:32+05:00
i02394404
© 2021 Caterpillar Inc.
Caterpillar:
Confidential Green