Logik 26S
Logik 26S
GENERAL INFORMATION
Logik26S have ;
• 8 opto isolated digital inputs
• 7 relay outputs
• 3 phase relay input (using with
Logika phase relay)
• 3 analog inputs
• Driver board with;
- 1 analog output
- 2 Pnp digital putput
- 1 digital input
• 2 RS485 serial communication
ports that supports Modbus
RTU communication protocol.
LOGIK 26S – How controls the compressor?
• Logik26S is capable to control the inverter according to control the pressure and airend
temperature.
• Logik26S also can control the inverter by using communication line.
• By its special software and hardware desing the airend temperature and the pressure
control can be controlled with inverter driver.
LOGIK 26S – How controls the compressor?
• Logik26S informs the user when any phase is missing or the phase sequence is wrong
• Logik26S tracks information of each phase against missing and sequence problem
situations. If any phase is missing then Logik26S informs the user with missing phase
label.
LOGIK 26S – How handles alarms?
Logik26S has intelligent alarm system by its special sofware design. There is a two stage
mechanism almost for each alarm. The user alway will be informed by a warning signal
before alarm occurs in the system.
Logik26S Alarms
Code Alarm Control Method
01 Emergency Stop Digital input
02 Motor Overload Digital input
03 Thermal Fan Digital input
04 No phase Phase control Relay (digital input)
05 Wrong phase Phase control Relay (digital input)
07 Door Open Digital input
09 Drive fault Communication / digital input
11 High pressure Parameter conrolled
LOGIK 26S – How handles alarms?
Logik26S has warning system. Before regarding alarm occurs on the system, Logik26S warns
the user by showing related warning message.
Logik26S Warnings
Logik26S Warnings
Logik26S has two different list visualization for alarm history and maintenance timers.
This speciality offers to user some functional benefits;
• Observation of each alarm with related occured date and time informations
• Service and maintenance process assurence and time decreases :
- Each alarm also refers to corresponding faulty parts.
- Each maintenance list record informs the user before maintenance duration occurs.
Logik26S also takes the inverter fault codes by using communication line. Thanks to this
Speciality;
• User is informed about the inverter fault code without authorized service inspection
LOGIK 26S – The control panel & Visualization?
Contrast
Waiting for Safety timer
Language
Set Pressure Reached
Date and time
Remote Start/Stop
Logik26S has 2 RS485 serial communication ports. Second communication port can be
used to communicate with inverter driver itself.
The main communication port can communicate under the system described below;
• Master / Slave Mode
• Multiunit
• Scada Systems
• Cloud Server
• Webserver
Note: If the compressor is not communicating with the driver, second RS485 port also
can be used to communicate with external modules & scada system as well.
LOGIK 26S – Communication / Master - Slave
RS485 line
Modbus Rtu Protocol
LOGIK 26S – Communication / Multiunit
RS232-RS485
Converter
RS485 line
Modbus Rtu Protocol
Slave Module
(Other Brand Compressors)
RS485 line
Modbus Rtu Protocol Cloud – Server