Logik 26S

The Logik 26S controller is an electronic control device suitable for operating medium to large screw compressors. It allows for visualization of compressor status and detects failures, automatically shutting down the machine. It can program 3 daily work cycles per week. It has 8 digital inputs, 7 relay outputs, 3 analog inputs, and 2 RS485 ports for Modbus RTU communication. It controls compressors and handles alarms through digital and analog inputs/outputs, parameters, and communication. It provides warnings before alarms occur and maintains lists of past alarms and maintenance timers.

Uploaded by

Ramsi Sembiring
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views

Logik 26S

The Logik 26S controller is an electronic control device suitable for operating medium to large screw compressors. It allows for visualization of compressor status and detects failures, automatically shutting down the machine. It can program 3 daily work cycles per week. It has 8 digital inputs, 7 relay outputs, 3 analog inputs, and 2 RS485 ports for Modbus RTU communication. It controls compressors and handles alarms through digital and analog inputs/outputs, parameters, and communication. It provides warnings before alarms occur and maintains lists of past alarms and maintenance timers.

Uploaded by

Ramsi Sembiring
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 21

LOGIK 26S CONTROLLER

GENERAL INFORMATION

Logik 26-S is an industrial electronic control device


suitable for the operation of medium-big size
screw compressors, both ON/OFF and Inverter
Technology.

Easy to install and set, Logik 26-S allows the


visualization in real time (9 different languages) of
the compressor status through the wide back-light
LCD provided; it detects also any type of failure,
turning off the machine automatically. Thanks to
the time keeper, Logik 26-S is able to programm 3
daily working cycles in a week.

Directives and Limits


• Conformity to EC and UL 508 regulation
• Inputs and outputs via terminal-block board to wires
• Black auto-extinguishing box in ABS
a) according EC: IP64 for the front panel and IP20 for the other parts;
b) according UL: Type 1 and Type 12 for front panel mounting, installation in pollution degree 2
for other parts
• Working temperature: 0°C (32°F) ÷ 50°C (122°F) 90% RH (non condensing)
• Power supply: 12Vac ± 10% 50 ÷ 60 Hz
LOGIK 26S – INPUTS / OUTPUTS

Logik26S have ;
• 8 opto isolated digital inputs
• 7 relay outputs
• 3 phase relay input (using with
Logika phase relay)
• 3 analog inputs
• Driver board with;
- 1 analog output
- 2 Pnp digital putput
- 1 digital input
• 2 RS485 serial communication
ports that supports Modbus
RTU communication protocol.
LOGIK 26S – How controls the compressor?

Digital Inputs (M5-M7) :


• IN1 : Emergency stop button
• IN2 : Thermal Motor Protec.
• IN3 : Thermal Fan Protec.
• IN4 : Remote / Start Stop
• IN5 : Air Filter Pressure Switch
• IN6 : Separator Filter Diff. Press.
Switch
• IN7 : Configurable input
• IN8 : Motor Ptc/Klickson input

Digital Outputs (M6) :


• RL1 : Line Contactor
• RL2 : Delta Contactor
• RL3 : Star Contactor
• RL4 : Selenoid Valve
• RL5 : Fan Contactor
• RL6 : Condasate Drain Selenoid
• RL7 : Alarm
RL2,RL5,RL6 and RL7 are configurable relay outputs according to end user needs.
LOGIK 26S – How controls the compressor?

Analog Inputs (M3):


• IN1 : Airend Temperature
• IN2 : Pressure Transducer
Drive Board (M9):
• Pole 1 : Digital Ground
• Pole 2 : Inverter Fault input
• Pole 3 : 4-20mA Output
• Pole 4 : Pnp1 digital output
• Pole 5 : Pnp2 digital output
• Pole 6 : 24Vdc power supply that
is coming from inverter side.

• Logik26S is capable to control the inverter according to control the pressure and airend
temperature.
• Logik26S also can control the inverter by using communication line.
• By its special software and hardware desing the airend temperature and the pressure
control can be controlled with inverter driver.
LOGIK 26S – How controls the compressor?

Digital Inputs (M4):

• Pole 1 : Ground connection which


comes from the phase relay
• Pole 2 : R-Phase information
• Pole 3 : S-Phase information
• Pole 4 : T-Phase information

• Logik26S informs the user when any phase is missing or the phase sequence is wrong
• Logik26S tracks information of each phase against missing and sequence problem
situations. If any phase is missing then Logik26S informs the user with missing phase
label.
LOGIK 26S – How handles alarms?

Logik26S has intelligent alarm system by its special sofware design. There is a two stage
mechanism almost for each alarm. The user alway will be informed by a warning signal
before alarm occurs in the system.
Logik26S Alarms
Code Alarm Control Method
01 Emergency Stop Digital input
02 Motor Overload Digital input
03 Thermal Fan Digital input
04 No phase Phase control Relay (digital input)
05 Wrong phase Phase control Relay (digital input)
07 Door Open Digital input
09 Drive fault Communication / digital input
11 High pressure Parameter conrolled
LOGIK 26S – How handles alarms?

Logik26S Alarms (Continue)

Code Alarm Control Method


12 Temperature probe failure Connectiviy check
13 High temperature Parameter controlled
14 Low temperature Parameter controlled
15 Separator filter Parameter controlled
18 Power off Internal electronic check
20 High Temp. Motor Digital input
21 Input power fault Internal electronic check
22 In7 configured open Parameter controlled
26 Press. Trans. Failure Connectivity check
27 Aux. Trans. Failure Connectivity check
LOGIK 26S – How handles alarms?

Logik26S Alarms (Continue)

Code Alarm Control Method


28 Low voltage Internal electronic check
29 safety Parameter controlled
30 High temperature warning Parameter controlled
32 Check compressor Parameter controlled
33 RS485 failure Communication software
60 Inverter failure Communication / digital input
62 Commnuication inverter Communication software
LOGIK 26S – How handles alarms?

Logik26S has warning system. Before regarding alarm occurs on the system, Logik26S warns
the user by showing related warning message.
Logik26S Warnings

Code Alarm Control Method

30 High temperature warning Parameter controlled

35 Data lost Epprom internal check

36 Air filter Parameter controlled

37 Multiunit failure Communication check

38 Separator filter Parameter controlled

39 Low voltage Internal electronics check


LOGIK 26S – How handles alarms?

Logik26S Warnings

Code Alarm Control Method

40 High voltage Internal electronics control

41 Clock failure Internal electronics control

42 Rs485 failure Communication software

43 Automatic change DLS timer Internal electronics control

47 Starts / hour Parameter controlled

61 Inverter failure Communication / digital input


LOGIK 26S – Alarm and Maintenance Lists

Logik26S has two different list visualization for alarm history and maintenance timers.
This speciality offers to user some functional benefits;
• Observation of each alarm with related occured date and time informations
• Service and maintenance process assurence and time decreases :
- Each alarm also refers to corresponding faulty parts.
- Each maintenance list record informs the user before maintenance duration occurs.

Logik26S also takes the inverter fault codes by using communication line. Thanks to this
Speciality;
• User is informed about the inverter fault code without authorized service inspection
LOGIK 26S – The control panel & Visualization?

Logik26S has a screen visualization with


the following features;
• Visualization through back light graphic LCD
(128x256 dots) and nr. 1 led for alarm status
• Messages selectable into 9 languages: Italian
– English – French – German – Spanish –
Portuguese – Turkish – Russian – Polish
• 6 buttons : Start (T6) – Stop (T5) – Reset(T4)
– Navigation(T1-T2) – Confirmation(T3)

Number Meaning Number Meaning


1 Status icons 6 Screw temperature
7a Inverter informations
2 Alarm icon with code
7b Inverter condition
3 Weekly schedule
8 Compressor status
4 Time
9 Working pressure, selenoid
status, electric motor
5 Cooling fan status status
LOGIK 26S – Icons and Meanings?

Drain selenoid Cooling fan is on

Multiunit Operation Inverter pid is active

Master Slave Stop pressure set

Maintenance Start pressure set

Alarm Electric motor status

Weekly Timer Load selenoid status

Compressor is off Temperature / pressure unit

Contrast
Waiting for Safety timer
Language
Set Pressure Reached
Date and time
Remote Start/Stop

Logik26S informs the user by using Compresor is on load

specified icons; Stopped by weekly timer

Waiting for internal pressure


LOGIK 26S – Weekly timer schedule

Logik26S has real time clock with


automatic DLS time setting function;

• User can define the compressor’s


working time duration by setting each
day’s start and stop time settings
• For each day 3 time interval can be
determined
• User can disable and enable the weekly
schedule timer by using start and stop
buttons
LOGIK 26S – Password Protection

Logik26S has 3 different password levels


regarding to menu access permissions.

• Service 1 : User level


• Service 2 : Authorized service level
• Service 3 : Factory level

Thanks to this special password protection


design, the risky and important parameters
security is provided and prevents unauthorized
person intervention into the parameters.
LOGIK 26S – Communication

Logik26S has 2 RS485 serial communication ports. Second communication port can be
used to communicate with inverter driver itself.

The main communication port can communicate under the system described below;
• Master / Slave Mode
• Multiunit
• Scada Systems
• Cloud Server
• Webserver

Note: If the compressor is not communicating with the driver, second RS485 port also
can be used to communicate with external modules & scada system as well.
LOGIK 26S – Communication / Master - Slave

Master / Slave communication functions :


• Balance Hours : Two compressors can be managed to balance the working hours
• Cascade working system with two compressors : By proper parameter settings user can
design cascade system where one compressor capacity is not sufficient to provide
pressurized air.
• Two inverter controller compressor can modulate at the same time by using special
inverter twin function.

Logik9 Logik33S Logik36S

RS485 line
Modbus Rtu Protocol
LOGIK 26S – Communication / Multiunit

Multiunit Communication Functions:


• Balance Hours : the working hours can be balanced
• Priority : Its possible to assing to compressor a priority
• Smart Mode : According to air consumption, the multiunit system selects the energy
saving combination with the compressor capacities.
Logik200 Multiunit Controller

RS232-RS485
Converter

RS485 line
Modbus Rtu Protocol

Slave Module
(Other Brand Compressors)

Logik9 Logik33S Logik26S


Up to 12 units can be controlled
LOGIK 26S – Communication / Ethernet Serial Gateway

Ethernet Serial Gateway:


• Embedded webserver mode: the compressor plant monitoring
• Cloud based mode : the compressor plant monitoring by using internet connection
• Modbus RTU -> Modbus TCP converter

Serial Ethernet Interface TCP/IP – WebServer Interface

Modbus RTU / Modbus TCP

RS485 line
Modbus Rtu Protocol Cloud – Server

TCP/IP – WebServer Interface

Up to 12 units can be connected


Thank You …